/All Products
  • Features:; High output Low current consumption Volume control Surface or rear cable entry Separate input and output terminals for ease of installation Uses patented technology
    Details
  • Features:; Simple to install Fits onto standard single gang back box Wide viewing angle high brightness LED Attractive styling
    Details
  • Quick and simple to install Stylish low profile design 360º viewable LED Removable detector chamber Drift compensation
    Details
  • Features:; LPC approved Low profile design Locking facility 360O viewing angle LED
    Details
  • Features; LPCB 3rd party approved Low profile design 360° viewable LED design Removable detector chamber for cleaning Common mounting base New enhanced detectors feature Drift compensation and Chamber monitoring (FXN533 & FXN632)
    Details
  • Key Features:; High immunity to a false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosions 1.3 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance Data/Event logger -alarms, faults, and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3 - Data Sheet F-Guard IR3 - Operators Manual
    Details
  • High immunity to false alarm Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions Hydrogen flame detection High sensitivity -up to 100 ft.(30m) HD video output with Automatic HD video recording of fire events Data/Event logger -alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-H2-HD - Data Sheet F-Guard IR3-H2-HD - Operators Manual
    Details
  • High immunity to false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire=High immunity to false alarm Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosion 1.2 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance HD video output with Automatic HD video recording of fire events. Data/Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-HD - Data Sheet F-Guard IR3-HD - Operators Manual
    Details
  • Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR - Operators Manual F-Guard UV-IR - Data Sheet
    Details
  • Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; FLS-UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range FLS-UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR-F - Data Sheet F-Guard UV-IR-F - Operators Manual