Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay

4 to 12 Zones

Twin Wire selection by DIL switch

Fully approved to EN54-2 & 4

Three year warranty as standard

Integral 3 Amp switch mode PSU

Class Change & Alert programmable inputs

Programmable relays and outputs

Test Mode (with or without sounders)

Alarm load of 2.4A shared across all sounder outputs

Modular expansion zone cards available

2 Additional sounder circuits with high spec expansion card

Fully functional repeater panels

Can support up to 8 repeater panels

Key-switch or code entry for activation of controls

Space for up to 7.0Ah batteries

Two monitored sounder circuits fitted as standard

Integral detector removal monitoring

SKU: Conventional Panel99 Category: Tag:

Description

Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay – QZXL-8HS

QuickZone XL is up to 12 zone Conventional / Twin Wire (sav-wire) control panel with integral power supply & space for standby batteries. The panel continues the attributes of quality and reliability, that is easy to install, maintain, and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays, Fire & Fault switched negative outputs; class change and an alert input are also included.

The fire zone outputs can be set as ‘Twin Wire’ by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1, the panel will indicate if there are any faults (Supply, Fire, System, General & repeater). As well as this, the panel is capable of indicating zones in Fire, Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode.

Controls enabled in Level 2 include Resound, Silence and Reset. Disable and Test modes can also be established at this level, as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3, it is possible to select sounder resound options for zones (EN54 requirement), select Type ‘A’ dependency per, view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Two Additional monitored sounder outputs, programmable switched negative outputs and one programmable relay available with high specification expansion card.

Key Features:

4 to 12 Zones

Twin Wire selection by DIL switch

Fully approved to EN54-2 & 4

Three year warranty as standard

Integral 3 Amp switch mode PSU

Class Change & Alert programmable inputs

Programmable relays and outputs

Test Mode (with or without sounders)

Alarm load of 2.4A shared across all sounder outputs

Modular expansion zone cards available

2 Additional sounder circuits with high spec expansion card

Fully functional repeater panels

Can support up to 8 repeater panels

Key-switch or code entry for activation of controls

Space for up to 7.0Ah batteries

Two monitored sounder circuits fitted as standard

Integral detector removal monitoring