//Morley FS20X IR2 UV Aluminium Flame Detector

Morley FS20X IR2 UV Aluminium Flame Detector

Patented WideBand IR™ Infrared combined with Ultraviolet

Detection range greater than 60 m (200 feet) to 0.1 m2 (1sq. ft.) heptane fire

Patented Electronic Frequency Analysis

Visible sensor for optimum false alarm rejection

Selectable detection sensitivities

Solar blind 90° field of view

Dual microprocessors for reliable performance

Real-time clock for accurate time dating of events

FirePic™ — Up to 6 pre-fire event data storage

Event log — Up to 200 events with date and time stamp

Built-in RS-485 ModBus communication

Built-in non-isolated 4-20 mA analog output (sink or source)

Alarm, Fault and Fire Verification relays

Automatic Optical Path and Electronic self-test

Patented Electronics Module for component protection with plug-in terminations for easy field installation

Two M25 conduit entries

Low power consumption; Morley Flame Detector – Data Sheet

Morley Flame Detector – Installation Guide

SKU: convhazard363 Category: Tag:

Description

Morley FS20X IR2 UV Aluminium Flame Detector

Based on the foundation of the highly successful and reliable SS4 detector, the FS20X detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X detector is a Multi-Spectrum and UV/Dual IR/VIS and flame detector with a proven UV solar-blind sensor. FS20X delivers a faster response and fewer false alarms, performs in a wider ambient temperature range, with a much longer detection range compared to conventional UV/IR detectors.

Conventional and older technology UV/IR detectors, using narrow band 4.3 micron IR sensors, will not always respond to smoky fires or if the detector lens is contaminated with oil and other substances since both UV and 4.3 micron signals are attenuated, obscured or absorbed by thick smoke or detector lens contaminations. All UV sensors will be attenuated to some degree.

Key Features:

Patented WideBand IR™ Infrared combined with Ultraviolet

Detection range greater than 60 m (200 feet) to 0.1 m2 (1sq. ft.) heptane fire

Patented Electronic Frequency Analysis

Visible sensor for optimum false alarm rejection

Selectable detection sensitivities

Solar blind 90° field of view

Dual microprocessors for reliable performance

Real-time clock for accurate time dating of events

FirePic™ — Up to 6 pre-fire event data storage

Event log — Up to 200 events with date and time stamp

Built-in RS-485 ModBus communication

Built-in non-isolated 4-20 mA analog output (sink or source)

Alarm, Fault and Fire Verification relays

Automatic Optical Path and Electronic self-test

Patented Electronics Module for component protection with plug-in terminations for easy field installation

Two M25 conduit entries

Low power consumption; Morley Flame Detector – Data Sheet

Morley Flame Detector – Installation Guide