Dual heat sensors Utilises digital CoreProtocol® communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest® for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) -
Low profile design Utilises digital CoreProtocol communications Compatible with Discovery and XP95 systems Integrated switchable isolator as standard 8-way DIL switch addressing Drift compensation FasTest for quicker testing Tricoloured LED status indicator Comprehensively tested to exceed EN 54-7 and EN 54-17 standards Ruggedized metal face plate which is secured with anti-tamper screws Designed and tested to meet the requirements of Ministry of Justice specification STD/E/SPEC/038 Independently certified to DHF TS001 for anti-ligature use in specialist areas -
Low profile design Utilises digital CoreProtocol communications Compatible with Discovery and XP95 systems Integrated switchable isolator as standard 8-way DIL switch addressing Drift compensation FasTest for quicker testing Tricoloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 and EN 54-17 standards Locking mechanism (grub screw) -
-
-
-
-
Multi-criteria fire sensing Enhanced detection certainty False alarm discrimination Fuzzy logic algorithms Selectable algorithms Microprocessor based Smoke element complies with EN54 Pt7 Heat element complies with EN54 Pt5 certification A1 -
Senses both smoke and heat Heat only facility Smoke element complies with EN54 Part 7 and CEA4021 Heat element complies with EN54 Part 5 Class A1 and A2 Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor -
Responds to slow burning fires Complies to EN 54 Pt7 Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor Alarm verification, self test, auto contamination adjustment -
Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor Automatic self test EN54 Part 5 approved -
Senses products of combustion from fast burning fires Complies to EN 54 Pt7 Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor Alarm verification, self test, auto contamination adjustment -
-
-
-
Universal Mode - EN54 pt.7 - CEA4021 - IS07240.7 Resilient Mode - EN54 pt.7 - CEA4021- IS07240.7 High Performance Optical - EN54 pt.7 - IS07240.7 Compensated CO Fire Sensing - LPS1265 - IS07240.6 Heat Detection - EN54 pt.5 A1R - IS07240.5 CO Toxic Gas Detection- EN50291 -
Protec Algo-Tec 6000PLUS Protocol Ideal for detecting shouldering fires Devices display address numbers Easy to address FAST addressing Reduce false alarms -
Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring -
-
Key Features:; Removable, High Performance chamber Twin LEDs allow 360 viewing – green when polling, turn red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB & VdS SIL Level 2 approved variants available Available in white; Enhanced Performance Chamber New Outer Cover Design Software Advances Increase Noise Immunity Fully backwards compatible -
Thermistor Heat Sensor Omniview 360° Direct replacement for ST-H-AS Robust Fully Modulated AS Communications Protocol EEPROM addressed (Address stored in on-board EEPROM, programmed by handheld programmer) -
Thermistor Heat Sensor Robust Fully Modulated AS Communications Protocol DIL Switch Addressed -
Latest Generation Nittan Optical Chamber Omniview 360° LED Robust fully modulated AS Communications Protocol EEPROM addressed (Address stored in on-board EEPROM, programmed by handheld programmer) WILL REPLACE ST-P-AS -
Optical Detector with built in Sounder Sounder ~ 85dB(A) @ ~ 3.1mA Drive Output for dedicated EV-PSBCN Evolution FSK protocol EEPROM Addressed (Programmer) -
Optical Smoke and 54°C (A1R) Heat Sensors in-one housing Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs -
54°C Heat Detector Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs -
Key Features:; Dual Optical Technology reduces false alarms Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs -
Optical Detector Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs -
Please Contact Us for Pricing & Availability. -
Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool -
-
2 or 4 loop versions as standard Larger enclosure available (fits 24A/H SLAs) Loopless panel option (repeater) 0, 16, 48, or 96 zone indicators Option for Enable Control keyswitch Fully supports Apollo, Argus Vega & Hochiki protocols Network up to 64 panels/repeaters 4 programmable sounder circuits as standard 5.25 amp power supply to EN54 part 4 Large graphic display In built help and alarm information screens Certified to EN54-2/ EN54-4 Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Sensitivity adjustment and Drift Compensation Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility -
Standard Features; Available in Red or Gray Up to 15 annunciators can be connected to each Elite fire control panel Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all panel controls Simple, two-wire serial connection Small, Elite style enclosure Removable electronics for easy installation 24V DC powered Low power consumption Multi language options Connection supervised by Elite fire control panel -
Large graphic display Simple connection to Syncro network 24V DC powered (230V AC available) Small attractive enclosure Configurable to display all or any events Simple to install Volt free Alarm, Fire and Fault contacts Up to 63 repeaters can be connected to a panel Focus+ with full controls has the following extra buttons: -
Large graphic display Simple connection to Syncro network 24V DC powered (230V AC available) Small attractive enclosure Configurable to display all or any events Simple to install Volt free Alarm, Fire and Fault contacts Up to 63 repeaters can be connected to a panelFocus+ with full controls has the following extra buttons: -
Key Features:; Up to 15 annunciators can be connected to each Syncro, Syncro Response or Syncro AS fire control panel. Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all Syncro panel controls Simple, two-wire serial connection Small, Syncro style enclosure Removable electronics for easy installation 24V DC or 230V AC power options Low power consumption Multi language options Connection monitored by Syncro fire control panel