Key Features: It is possible to set individual control of the sounder and visual indicator Volume and tone settings can be selected from the control panel Electronic bell tone IMO 1A tone included -
Key Features: Resettable operating element Easy access, front reset mechanism Front facing accessible addressing for commissioning Ergonomic reset key and keyring hole Flashing Poling LED Option 170 viewable LED indicator -
Key Features: Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security -
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C -
Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C -
Key Features: ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C -
Key Features ATEX certified IECEx certified -
Key Features: Continually corrects itself against building movement Controlled and adjusted from ground level Use XP95 Switch Monitor to interface it to an addressable loop -
The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Not suitable for Base Mounted Flame Detectors. Key Features: Allows flame detector to be mounted in any orientation. -
Key Features Protects against water ingress Protects sensor from direct sunlight