Key Features:; Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Conventional IR Installation Guide Apollo - IR Flame Detector - Datasheet Apollo - Conventional IR Flame Detector -Datasheet -
Key Features:; Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Installation Guide Apollo - Flame Detector Datasheet -
Key Features:; Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C Operating temperature -10°C to +55°C; Apollo - Product Datasheet Apollo - Installation Guide Apollo - Datasheet -
Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Installation Guide -
Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Flameproof Datasheet Apollo - Flameproof Installation Guide -
ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide -
ATEX & IECEx certified: II 1 G CENELEC/IEC Certified: Ga Ex ia IIC T4 Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +40°C (T4) Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Datasheet (1) Apollo - Datasheet (2) Apollo - Product Guide Apollo - Installation Guide Apollo - Datasheet (3) -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Intrinsic Safety - Datasheet Apollo - I.S. Detector - Installation Apollo - I.S. Detector - Product Guide Apollo - Datasheet Apollo - Orbis - Datasheet Apollo - Leaflet -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Guide Apollo - Datasheet Apollo - Datasheet (2) Apollo - Datasheet (3) Apollo - Leaflet -
Environmental Characteristics; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Installation Instructions Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - I.S Detector - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - Datasheet -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S Detector - Datasheet Apollo - I.S. Detector - Installation Guide Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - Datasheet Apollo - Intrinsic Safety - Datasheet