/C-Tec
  • a stand-alone base device using a separately available locking white cap (BF330CTLIDW) / red cap (BF330CTLIDR), or a combined base device and detector (detectors are separately available and wired on a separate detection circuit). The base devices are compatible with C-TEC’s range of ActiV conventional detectors and other compatible third-party suppliers.; Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'O-R-3-2.5-17' light distribution. Ideally suited for use in corridors and other rectangular areas. Impressive 96dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • a stand-alone base device using a separately available locking white cap (BF330CTLIDW) / red cap (BF330CTLIDR), or a combined base device and detector (detectors are separately available and wired on a separate detection circuit). The base devices are compatible with C-TEC’s range of ActiV conventional detectors and other compatible third-party suppliers.; Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'C-3-8.5' light distribution (min 0.4 lux over a 3 x 8.5m cylindrical area). Impressive 96dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • LPCB certified to EN54-3 (Sounders). Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Alarm Current at 30Vdc = 5.5mA. Alarm Current at 18Vdc = 3.8mA. IP55C rated (weatherproof). Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders). Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Alarm Current at 30Vdc = 5.5mA. Alarm Current at 18Vdc = 3.8mA. IP21C rated. Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as a W-4-4 VAD. Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) IP33C rated. Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Alarm Current at 30Vdc = 5.5mA. Alarm Current at 18Vdc = 3.8mA. IP33C rated. Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as W-4-4 VAD. Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) IP55C rated (weatherproof). Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as a W-4-4 VAD. Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) IP21C rated. Manufactured in the UK by C-TEC.
    Details
  • Superb sound intelligibility. Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone). Provides 'O-R-3-2.5-17' light distribution using the same lenses and electronics as our EN54-3 & 23 certified base sounder VAD. Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 17mA (0.5Hz) or 24mA (1Hz) Alarm Current at 18Vdc = 18.5mA (0.5Hz) or 30mA (1Hz) Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Can also be used as a W-4-4 VAD. Superb sound intelligibility. Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone). Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 17mA (0.5Hz) or 24mA (1Hz) Alarm Current at 18Vdc = 18.5mA (0.5Hz) or 30mA (1Hz) IP33C rated. Manufactured in the UK by C-TEC.
    Details