  • The multi-sensor combines heat (H), carbon monoxide (CO), optical forward scatter (OFS) and optical backward scatter (OBS) The patented dual angle optical scatter technology allows identification of the particle source filtering potential false alarms due to steam and dust The gas sensing element (CO) within the chamber monitors the concentration of carbon monoxide, a product of incomplete combustion in some fire types, and potentially life threatening. The CO sensor allows rapid fire detection, with smouldering fires, in areas where smoke detectors could register false alarms Combined CO gas sensing with dual angle optical and heat allows a higher level of false alarm immunity whilst still improving the detection speed of certain types of fire Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night Repeat fire LED output as standard (if monitored input not used) Operational LED blink ‘On/Off’ option Monitored Input - which can be Fire, Fault or Supervisory
    Details
  • Sensor and alarm in one device reduces installation time and cost. Built-in high intensity VAD helps alert occupants in noisy environments as well the hard of hearing Meets all the requirements of the Equality Act 2010 Compatible with the S-Cubed wall mounted VAD State of the art, high efficiency visual alarm technology Advanced power management that increases loop capacity and integrity Range of devices and power settings to suit widest range of building applications Light output that allows devices to be sited at standard smoke and heat detector spacings Synchronised flash rate across the whole control panel avoiding risk of induced seizures VAD can operate independently of the sounder if required Meets the requirements of BS5839 part 1 relating to sensitivity to epilepsy
    Details
  • Sensor and alarm in one device reduces installation time and cost. Built-in high intensity VAD helps alert occupants in noisy environments as well the hard of hearing Meets all the requirements of the Equality Act 2010 Compatible with the S-Cubed wall mounted VAD State of the art, high efficiency visual alarm technology Advanced power management that increases loop capacity and integrity Range of devices and power settings to suit widest range of building applications Light output that allows devices to be sited at standard smoke and heat detector spacings Synchronised flash rate across the whole control panel avoiding risk of induced seizures VAD can operate independently of the sounder if required Meets the requirements of BS5839 part 1 relating to sensitivity to epilepsy
    Details
  • Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night Repeat fire LED output as standard (if monitored input not used) Operational LED blink ‘On/Off’ option Monitored Input - which can be Fire, Fault or Supervisory
    Details
  • The multi-sensor combines heat (H), carbon monoxide (CO), optical forward scatter (OFS) and optical backward scatter (OBS) The patented dual angle optical scatter technology allows identification of the particle source filtering potential false alarms due to steam and dust The gas sensing element (CO) within the chamber monitors the concentration of carbon monoxide, a product of incomplete combustion in some fire types, and potentially life threatening. The CO sensor allows rapid fire detection, with smouldering fires, in areas where smoke detectors could register false alarms Combined CO gas sensing with dual angle optical and heat allows a higher level of false alarm immunity whilst still improving the detection speed of certain types of fire Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night Repeat fire LED output as standard (if monitored input not used) Operational LED blink ‘On/Off’ option Monitored Input - which can be Fire, Fault or Supervisory
    Details
  • Attention tones can be programmed to match system sounders Volume control for individual devices including ’Soft’ start option Uniform sound distribution at all angles Low current consumption with capacity for up to 125 units per loop Fully synchronised sound patterns via the control panel Voiced Enhanced option with selectable speech messages available to suit most requirements Rich harmonic sound output using patented technique Unique monitoring of sounder element to ensure operation in an emergency Output typically 90dB(A) @1m Self-monitoring to prevent overload of loop in event of cable fault; S-Quad Benefits:; Comprehensive range of analogue addressable fire sensors all within ONE device Supported and powered on the Vigilon Loop – only one set of terminations and one cable required for multisensor, sounder, speech and visual alarm functionality Increased loop alarm load capable of powering 200 sensor-sounders or 100 sensor-sounder VADs Built-in short circuit isolators in every device Monitored input facility – fire, fault, non-fire – reduces the installed cost of the system and reduces the need for separate interfaces Monitored repeat LED output Loop powered installation incorporating S-Quad requires no additional interfaces or extra monitored sounder circuits S-Quad’s intelligent design ensures quick and simple installation with more wiring space within the base
    Details
  • Each loop can support up to 200 voice sounders, 100 visual alarm devices (VADs) and up to 70 combined sounder VADs EN54-23 VADs with adjustable light coverage matching the sounder output Comprehensive and easy to use design and commissioning tools Four voice phrases and a bell tone available as standard Voice and tone modes can be freely configured within the same sounder Active background monitoring of sounder and VAD circuits Adjust the sounder volume via the commissioning tool, the panel or the HandiLink infrared remote control
    Details
  • Each loop can support up to 200 voice sounders, 100 visual alarm devices (VADs) and up to 70 combined sounder VADs EN54-23 VADs with adjustable light coverage matching the sounder output Comprehensive and easy to use design and commissioning tools Four voice phrases and a bell tone available as standard Voice and tone modes can be freely configured within the same sounder Active background monitoring of sounder and VAD circuits Adjust the sounder volume via the commissioning tool, the panel or the HandiLink infrared remote control
    Details
  • Very low power consumption means more sounders per loop e.g. 200 system sounders per loop compared to 40 The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power The strobe element of the sounders is fully monitored for circuit failures The sounder tones are programmed in exactly the same way as the existing Vigilon sounders Loop powered voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard By using the bell sound in the voice sounder it is possible to have a loop powered bell The sound producing element in the voice sounders is monitored every hour using a VLF tone Voice and Tone mode can be freely mixed within the same sounder All messages and strobe signals are synchronised across loops in the same control panel Complements the S-Quad sensor with voice messages and complex sound signals A backwards compatible version of the system sounder is available for replacement or expansion to existing systems, avoiding the need to upgrade panel software The HandiLink remote control makes it much easier to adjust the sounders in situ Products incorporate innovative design features for which multiple patents are pending High intensity flashing strobe conforms to the Disability Discrimination Act (DDA) 1995 legislation
    Details
  • Very low power consumption means more sounders per loop e.g. 200 system sounders per loop compared to 40 The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power The strobe element of the sounders is fully monitored for circuit failures The sounder tones are programmed in exactly the same way as the existing Vigilon sounders Loop powered voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard By using the bell sound in the voice sounder it is possible to have a loop powered bell The sound producing element in the voice sounders is monitored every hour using a VLF tone Voice and Tone mode can be freely mixed within the same sounder All messages and strobe signals are synchronised across loops in the same control panel Complements the S-Quad sensor with voice messages and complex sound signals A backwards compatible version of the system sounder is available for replacement or expansion to existing systems, avoiding the need to upgrade panel software The HandiLink remote control makes it much easier to adjust the sounders in situ Products incorporate innovative design features for which multiple patents are pending High intensity flashing strobe conforms to the Disability Discrimination Act (DDA) 1995 legislation
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences Automatic adaptation to varying environmental influences Electronic compensation of long-term influences of contamination or aging
    Details
  • Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences Automatic adaptation to varying environmental influences Electronic compensation of long-term influences of contamination or aging
    Details