Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface -
Up to 320 LED’s can be controlled Full colour printing Available in a range of standard enclosures to suit any application Bespoke sized units can be made upon request Choice of Red, Green or Yellow LED’s Available with or without controls Same look and feel as Sigma range Sigma Matrix can easily be upgraded on site with minimal cost and effort -
UL864 approved Two, four or eight initiating circuits Initiating circuits individually configurable as Fire, Water flow or Supervisory Two 2A notification appliance circuits Selectable NAC sync protocols Two 2.0A notification appliance circuits 6.5A power supply Alarm verification selectable by zone Resettable Aux power output rated at 0.3A Aux power configurable to power off on Fire condition Fire, Trouble and Supervisory relays Single person walk test function Optional DACT Many advanced configuration options 72 hour standby with 7Ah batteries Compact enclosure Fire Drill capability -
"Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration" -
"Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration" -
"Two-wire and standard versions in two, four or eight zones Compatible for use on BS5839: Part 1: 2017 installations Two-wire repeaters and ancillary boards Simple, single board construction Compatible with wide range of detection devices Two monitored sounder outputs Three Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration" -
"Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs" -
"Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface" -
Key Features:; 2 minutes to fit on site Kit available from stock Colour to match standard Control Panel ranges Special colours available on request Attractive design Key lockable -
Fully welded, all steel construction Tough epoxy powder coated finish Key lockable Wide range of styles and sizes Up to 65Ah batteries can be fitted Fully enclosed and robust construction -
Key Features:; Available with red or yellow high brightness, flashing LED indicators Can be used for Fire alarm warning, activated by a sounder circuit or to indicate and initiate an active isolation Optional silence buzzer keyswitch Disable buzzer option via internal jumper link Optional Keyswitch to perform isolation Terminations for incoming and outgoing wiring Surface mounted box supplied Front panel can be fitted to a single gang UK back box -
Key Features:; Available with red or yellow high brightness, flashing LED indicators Can be used for Fire alarm warning, activated by a sounder circuit or to indicate and initiate an active isolation Optional silence buzzer keyswitch Disable buzzer option via internal jumper link Optional Keyswitch to perform isolation Terminations for incoming and outgoing wiring Surface mounted box supplied Front panel can be fitted to a single gang UK back box -
Key Features:; High brightness red LED indicators for reliability and low power consumption Wide viewing angle LEDs flash alternately to easily attract attention Units to fit to standard gang or round electrical back boxes Compatible with conventional and addressable detectors Printed with “FIRE ALARM IN CON CEALED SPACE” as standard Custom printing and languages available on request -
2.5A and 5.25A versions Chassis only or enclosure mounted with battery space 110V or 230V input Regulated, true 24V output Intelligent battery charging and temperature compensation House up to 26Ah batteries Status indicators for monitored faults Dual output option for powering fire alarm control panels remotely Chassis versions have same mounting points -
2.5A and 5.25A versions Chassis only or enclosure mounted with battery space 110V or 230V input Regulated, true 24V output Intelligent battery charging and temperature compensation House up to 26Ah batteries Status indicators for monitored faults Dual output option for powering fire alarm control panels remotely Chassis versions have same mounting points -
-
Key Features:; High brightness red LED indicators for reliability and low power consumption Wide viewing angle LEDs flash alternately to easily attract attention Units to fit to standard gang or round electrical back boxes Compatible with conventional and addressable detectors Printed with “FIRE ALARM IN CON CEALED SPACE” as standard Custom printing and languages available on request -
Continuous 8A load output while charging fully depleted batteries Charges up to 45Ah batteries Approved to EN54-4 94V to 253V AC input Mains fail monitoring with LED indication and output Battery disconnection monitoring with LED indication and output Low battery monitoring with LED indication and output Earth fault monitoring with LED indication and output Low battery cut out Temperature compensated battery charging -
2.5A and 5.25A versions Chassis only or enclosure mounted with battery space 110V or 230V input Regulated, true 24V output Intelligent battery charging and temperature compensation House up to 26Ah batteries Status indicators for monitored faults Dual output option for powering fire alarm control panels remotely Chassis versions have same mounting points -
Continuous 8A load output while charging fully depleted batteries Charges up to 45Ah batteries Approved to EN54-4 94V to 253V AC input Mains fail monitoring with LED indication and output Battery disconnection monitoring with LED indication and output Low battery monitoring with LED indication and output Earth fault monitoring with LED indication and output Low battery cut out Temperature compensated battery charging -
-
-
-
-
2 minutes to fit on site Kit available from stock Colour to match standard Control Panel ranges Special colours available on request Fits any M2, H2, M3, H3 and M4 sized control panel Attractive design Key lockable -
Two four or six way units available Integral power supplyRobust steel enclosure Space for 7Ah batteries Power Healthy, Power Fault and Sounder Fault indicators Full fault monitoring and integrity maintained -
Features; Two wire serial connection Up to 7 sounder boards per system 230V AC or 24V DC powered versions Zoned, 2-stage or common alarm All outputs monitored for open and short circuit faults Individual open and short circuit fault indicators Fully monitored by main control panel Class change input facility Up to 8 outputs with 0.5A available from each Can be connected to serial bus with Ancillary boards and repeaters Boxed units in enclosure to match Sigma CP control panels Power fault input for monitoring remote power supplies -
Features:; Two wire serial connection Up to 7 boards per system 230V AC or 24V DC powered versions Open collector zonal fault outputs Volt free fire, coincidence and common fault contact outputs -
Variants Available: -
Variants Available: -
-
Easy to install No additional wiring point Low cost Sub-miniature design Environmentally sealed -
Key Features:; Expandable from 1 to 2 loops Network up to 64 panels 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Powerful cause and effects Sensitivity adjustment and Drift Compensation Compatible with View Marine repeaters Supports Apollo and Hochiki protocols Stores 500 last events in event log Installer friendly, removable equipment chassis Different language and character set variants available Approved and certified to EN54-2/ EN54-4 -
Key Features:; Expandable from 1 to 2 loops Network up to 64 panels 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Powerful cause and effects Sensitivity adjustment and Drift Compensation Compatible with View Marine repeaters Supports Apollo and Hochiki protocols Stores 500 last events in event log Installer friendly, removable equipment chassis Different language and character set variants available Approved and certified to EN54-2/ EN54-4 -
Key Features:; Expandable from 1 to 2 loops Network up to 64 panels 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Powerful cause and effects Sensitivity adjustment and Drift Compensation Compatible with View Marine repeaters Supports Apollo and Hochiki protocols Stores 500 last events in event log Installer friendly, removable equipment chassis Different language and character set variants available Approved and certified to EN54-2/ EN54-4 -
Key Features:; Expandable from 1 to 2 loops Network up to 64 panels 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Powerful cause and effects Sensitivity adjustment and Drift Compensation Compatible with View Marine repeaters Supports Apollo and Hochiki protocols Stores 500 last events in event log Installer friendly, removable equipment chassis Different language and character set variants available Approved and certified to EN54-2/ EN54-4