-
"Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration" -
UL864 approved Two, four or eight initiating circuits Initiating circuits individually configurable as Fire, Water flow or Supervisory Two 2A notification appliance circuits Selectable NAC sync protocols Two 2.0A notification appliance circuits 6.5A power supply Alarm verification selectable by zone Resettable Aux power output rated at 0.3A Aux power configurable to power off on Fire condition Fire, Trouble and Supervisory relays Single person walk test function Optional DACT Many advanced configuration options 72 hour standby with 7Ah batteries Compact enclosure Fire Drill capability -
Up to 320 LED’s can be controlled Full colour printing Available in a range of standard enclosures to suit any application Bespoke sized units can be made upon request Choice of Red, Green or Yellow LED’s Available with or without controls Same look and feel as Sigma range Sigma Matrix can easily be upgraded on site with minimal cost and effort -
Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface -
Sigma CP-R Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs Ancillary PCB Two wire serial connection Up to 7 boards per system 230V AC or 24V DC powered versions Open collector zonal fault outputs Volt free fire, coincidence and common fault contact outputs -
2 wire systems, reduces installation cabling 2-wire repeaters and ancillary boards via serial bus Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay for detectors only Zonal sounder delay for call points only Coincidence output via ancillary board Short circuit fire selectable by zone Non latching selection by zone Silent zones (common sounder outputs) Zone input delay for sprinkler system connection AlarmSense® local alarm feature supported Simple, single board construction Installer friendly Compatible with all AlarmSense® devices Two conventional monitored sounder outputs 3 Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Allows systems to be installed in accordance with BS5839: Part 6 -
Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options:; Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output -
Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options:; Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output -
2 or 4 loop versions as standard Larger enclosure available (fits 24A/H SLAs) Loopless panel option (repeater) 0, 16, 48, or 96 zone indicators Option for Enable Control keyswitch Fully supports Apollo, Argus Vega & Hochiki protocols Network up to 64 panels/repeaters 4 programmable sounder circuits as standard 5.25 amp power supply to EN54 part 4 Large graphic display In built help and alarm information screens Certified to EN54-2/ EN54-4 Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Sensitivity adjustment and Drift Compensation Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility -
Standard Features; Available in Red or Gray Up to 15 annunciators can be connected to each Elite fire control panel Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all panel controls Simple, two-wire serial connection Small, Elite style enclosure Removable electronics for easy installation 24V DC powered Low power consumption Multi language options Connection supervised by Elite fire control panel -
Large graphic display Simple connection to Syncro network 24V DC powered (230V AC available) Small attractive enclosure Configurable to display all or any events Simple to install Volt free Alarm, Fire and Fault contacts Up to 63 repeaters can be connected to a panelFocus+ with full controls has the following extra buttons: -
Large graphic display Simple connection to Syncro network 24V DC powered (230V AC available) Small attractive enclosure Configurable to display all or any events Simple to install Volt free Alarm, Fire and Fault contacts Up to 63 repeaters can be connected to a panel Focus+ with full controls has the following extra buttons: