Long term service and support Supports 1 MXDigital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 16 Zone Fully Functional Mains powered Repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839 Easy programming when using MXConsys Express configuration tool.
-
Long term service and support Supports 1 MXDigital loop with 250 addresses 2 KM loop length 32 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 32 Zone Fully Functional Mains powered repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839
-
-
PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating one MZX DIGITAL loop CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers BV, UL, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions
-
EN54 Compliant MXDigital system Integral power supply Optional integral eighty way zonal LED’s Two to eight loops or network up to 396 loops 250 addresses per loop Full range of MZX virtual multi-sensor detectors MZX FASTLOGIC fuzzy logic smoke detection algorithms Fully functional repeater Powerful MXConsys & MXConsys Express configuration software Easy to install Space for 17Ah or 38Ah batteries
-
FIM800 field interface PCB incorporating one or two MZX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers LPCB, BV, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions
-
Long term service and support Two way IR communications with Generation 6 Detectors reduces commissioning and service costs. Supports 1 MZX Digital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with “Front Panel Controls” to reduce lifetime cost of ownership Wide range of multi-sensor detectors including the 3oTec triple sensing detections. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 "Critical" Matching 16 Zone Fully Functional Mains powered Repeater Approved to EN54 the system is designed to be installed to BS5839
-
Please Contact Us for Pricing & Availability.
-
Universal Mode - EN54 pt.7 - CEA4021 - IS07240.7 Resilient Mode - EN54 pt.7 - CEA4021- IS07240.7 High Performance Optical - EN54 pt.7 - IS07240.7 Compensated CO Fire Sensing - LPS1265 - IS07240.6 Heat Detection - EN54 pt.5 A1R - IS07240.5 CO Toxic Gas Detection- EN50291
-
-
-