/Tyco
  • Key Features:; Dual pole 24Vdc relay contact (60VA) Status indicator LED Low power consumption (<20uA except start up) Latching operation Can be used instead of a standard base Requires diode fitting if used in place of a diode base.
    Details
  • Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • PSB800 5A 24Vd.c. battery backed power supply and loop booster FIM801CV field interface PCB incorporating one MX DIGITAL loop CPU800 32 bit processor and memory Card XLM800 loop expansion card containing two MX Digital loops Optional remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating two MX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card(s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists firefighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • The mode of detector may be:; Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) These detectors are designed to comply with EN/IEC 60079-0:2006, EN/IEC 60079-11:2007 and EN/IEC 61241-11:2006 for intrinsically safe apparatus; ATEX Code: Ex II 1GD Cenelec Code: Ex ia IIC T5/Ex iaD 20 T100oC
    Details
  • Key Features:; Unlike UV and UV/IR detection, not blinded by oil mist in machinery spaces Reduces cabling, no interface required No additional power source required Easy installation uses a common plug in base for smoke and heat detectors Can be used on all vessels as fully marine approved
    Details
  • Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Remote detector verification & temperature read out Programmable alarm LED with 360o viewing angle Optional detector locking pin Variety of sounder and relay detector bases Address flag stays with the base Approved by all major classification societies for use on vessels Lower cost system design and installation as one detection type can be used throughout the vessel Lower cost of ownership as no radioactive source disposal costs together with less spares holding Enhanced safety in accommodation areas by using the unique Carbon Monoxide (CO) detectors Major Cable saving options using loop powered ancillaries Allows easier decision making by operator because of remote temperature and smoke density read-out
    Details
  • Advanced multi-sensor designs Built-in line isolator (851PH Only) Quick and easy to install Extended drift compensation Two way infra-red communication to the 850EMT Engineering Management Tool Fire, isolate and fault LED indications Any Pantone colour available with CPD approval Comprehensive range of bases and base accessories
    Details
  • Intelligent Universal Smoke Detector Low profile, discreet and unobtrusive Superior performance and reliability Attractive new design Smart Card Addressing Technology Designed for fast easy installation Optional Locking Kit May be used in systems that meet BS5839 Pt1 Integral and remote alarm LED Wiring polarity independent LPCB approved to EN54
    Details
  • Key Features:; Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Remote detector verification & temperature read out Programmable alarm LED with 360o viewing angle Optional detector locking pin Variety of sounder and relay detector bases Address flag stays with the base Approved by all major classification societies for use on vessels Lower cost system design and installation as one detection type can be used throughout the vessel Lower cost of ownership as no radioactive source disposal costs together with less spares holding Enhanced safety in accommodation areas by using the unique Carbon Monoxide (CO) detectors Major Cable saving options using loop powered ancillaries Allows easier decision making by operator because of remote temperature and smoke density read-out
    Details
  • Communication and control interface to MZX Technology Fire Controllers Approved to EN54-13 ensuring system compatibility Integrated short-circuit isolator removes the need of installing a separate short-circuit isolator Reduced installation costs Meets the requirements of EN54 Pt. 11 and EN54 Pt. 17. Marine Approved
    Details
  • Communication and control interface to MZX-Technology Fire Controllers Approved to EN54-13 ensuring system compatibility Integrated short-circuit isolator removes the need of installing a separate short-circuit isolator Reduced installation costs Meets the requirements of EN54 Pt. 11 and EN54 Pt. 17. IP67 rating for outdoor installations Marine Approved
    Details
  • Key Features:; Solar Blind for false alarm free operation Marine approved Fast response to flame Detect a 0.1m2 fire at a range of 20m Discrete ultra-low profile design Fits a standard detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors
    Details
  • Solar Blind for false alarm free operation Fast response to flames Detect a 0.1m² fire at a range of 20m Automatic health check feature Discrete ultra-low profile design Fits a standard MZX detector base or functional base Integral alarm LED with 360º angle of view Use T110 infrared test source (With separate adapter)
    Details
  • Key Features:; Approved by all major classification societies for use on vessels EN54 Approved from LPCB Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Wiring polarity independent
    Details
  • EN54 Approved from LPCB Marine approved Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Integrated alarm LED Remote LED connection Wiring polarity independent; Applications used in:; kitchens, locker rooms canteens loading bays etc.
    Details
  • Key Features:; Approved by all major classification societies for use on vessels EN54 Approved from LPCB Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Wiring polarity independent
    Details
  • Key Features:; Integral LED for easy identification of operation Call points are identified separately at the controller even for conventional panels For ease of installation various configurations are available Accidental operation can be prevented by optional covers
    Details
  • Key Features:; Integral LED for easy identification of operation Call points are identified separately at the controller even for conventional panels For ease of installation various configurations are available Accidental operation can be prevented by optional covers
    Details
  • Power beam detectors directly from the MX Digital loop Reduced wiring and installation costs Monitors beam detector for fire and fault Inter-connection monitored for open and short circuit faults LPCB and VdS appoved (pending) Can be installed to BS5839 Part 1 2002 On board LED indicated polling and active Use with reflective beams FIRERAY 50R or 100R for greater savings on installation Compatible with FIRERAY 2000 beam detector Optional BTM800 beam terminaltion module to further simplify installation
    Details
  • DPK6 for use with Generation6 multi-sensor detectors 850PH and 830PH with built-in 4B-C 4” Continuity Base Designed to comply with EN 54-27 One-pipe air sampling system Patented venturi pipe and duct housing Test hole on cover Simple installation Simple service and maintenance
    Details
  • Glass Reinforced Polyester Enclosure - light, strong and not subject to corrosion. Resettable Element. Explosion protected EExe (ATEX Approved). In line and end of line resistors. Red Epoxy Finish. 7 x terminals. Lift flap for extra protection against inadvertent operation. 1 x changeover switch. Captive cover screws. Key operated test facility - simple but secure. 1 x M20 bottom cable entry.
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Heat only detector (A1R or A2S) (no sensitivity selection) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)combined with heat (A1R) Carbon Monoxide Detector (sensitivity: High, Normal or Low); ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
    Details
  • Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Automatic health check feature Discrete ultra low profile design Fits a standard MX detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors
    Details