//Aritech FD2710R 2000 Series Addressable Reflective Beam Detector (100m)

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector (100m)

Loop Powered

2000 series protocol

Area coverage up to 600 m²

Range from 5 – 50 m and 50 – 100 m

Up to ceiling heights of 25 m

Low current consumption

3 selectable alarm thresholds

Self-check and automatic contamination compensation

Automatic discrimination between fire and fault

Vertical or horizontal mount

Easy wiring and unique alignment

Microprocessor controlled

Conforms to BS5839 part 5 and EN54

SKU: Beamdetect13 Category: Tag:

Description

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector (100m)

The FD2705R and FD2710R provides an integral, loop powered analogue addressable reflective beam detector up to 100m distance. Wiring is restricted to a minimum as the transmitter and receiver are in the same housing. The detector is very easily aligned by means of checking the alignment LEDs. Easy alignment ensures optimum operation, both electrically and mechanically. The unit is easily tested using the graduated obscuration test card supplied.

The low power consumption of the units allows multiple beams to be powered on the same loop without compromising the system’s autonomy. The FD2705R and FD2710R consist of an infrared transmitter and receiver in one single compact housing. The infrared signal is reflected by a prism and analysed for smoke presence. It is particularly designed to be use where point smoke detectors are not practical due to height or inaccessibility.

The FD27xxR series units are loop powered for connection to 1200/2000 series fire panels. They use the Aritech 2000 series protocol. Various alarm thresholds may be selected from to suit the environment. If the signal reduces to below the selected threshold and is present for ±10 seconds, a fire condition is signalled. If the infrared beam is obscured rapidly to a level of 90 % or greater for ±10 seconds, a fault condition is signalled. The detector monitors long term degradation of signal strength caused by component ageing or build-up of dirt on optical surfaces.

Key Features:

Loop Powered

2000 series protocol

Area coverage up to 600 m²

Range from 5 – 50 m and 50 – 100 m

Up to ceiling heights of 25 m

Low current consumption

3 selectable alarm thresholds

Self-check and automatic contamination compensation

Automatic discrimination between fire and fault

Vertical or horizontal mount

Easy wiring and unique alignment

Microprocessor controlled

Conforms to BS5839 part 5 and EN54