“Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB)

Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry

Manufactured by C-TEC in the UK

Two detector zone circuits

Four conventional sounder circuits

Integral 1.5A EN54-4/A2 compliant switch mode PSU

Wide range of test and fault-finding facilities

Four open-collector outputs (Fire, Fault, Remote and Reset)

‘Class change’ and alert inputs

Installer-friendly design

Attractive flush or surface mountable plastic lid and enclosure – no bezel required

Low 25mA quiescent current

Multiple indicators

No system expansion connections

Fully compatible with C-TEC’s ActiV range of conventional fire detectors”

SKU: Conventional Panel78 Category: Tag:

Description

“C-Tec Economy CFP 4 Zone Conventional Fire Panel CFP704E-4

LPCB certified to EN54-2/4, C-TEC’s CFP 4 zone economy fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, four open collector outputs (fire, fault, reset and remote) and combined keypad/keyswitch entry.

Unlike our Standard CFP fire panel, the CFP704E-2 is NOT compatible with CFP repeaters, relay expansion boards or EN54-13 interface cards. It also has limited engineering functions.

Key Features:

Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB)

Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry

Manufactured by C-TEC in the UK

Two detector zone circuits

Four conventional sounder circuits

Integral 1.5A EN54-4/A2 compliant switch mode PSU

Wide range of test and fault-finding facilities

Four open-collector outputs (Fire, Fault, Remote and Reset)

‘Class change’ and alert inputs

Installer-friendly design

Attractive flush or surface mountable plastic lid and enclosure – no bezel required

Low 25mA quiescent current

Multiple indicators

No system expansion connections

Fully compatible with C-TEC’s ActiV range of conventional fire detectors

Economy CFP fire panels (without LPCB certification, onboard relays, system expansion connections, delay, coincidence or non-latching zone facilities) are also available.”