CB200 1 Zone Conventional Fire Alarm Panel

Built in detector removal indication facility

From 1 to 8 zones

4 Alarm circuits on 4-8 zone panels

Conforms to the requirements of EN54-2

User friendly access code

one-man test facillity

Non-latching zone feature

Class change input

Earth fault monitoring

Fully functional repeater available (4 & 8 zone panels only)

Removable cable entry grommets

User friendly controls

Surface or semi-flush mounting as standard

Ample termination space

Flame restant polycarbonate enclosure

Log book and manual supplied

Complies with SMC and LVD directives

SKU: Conventional Panel88 Category: Tag:

Description

***PLEASE NOTE*** – Under the regulations only products approved to current EN standards may be CE marked for use in installation within the EU, countries other than EU are not affected.

We advise that the following products will not carry the CE marking and therefore should not be used on new installation within EU from July 1st 2013

CB200 1 Zone Conventional Fire Alarm Panel

The CB200 conventional panel may be supplied in 1, 2, 4 and 8 zone formats. It complies with the requirements of EN54 Part 2. All zones and alarm circuits are monitored for open and short circuit fault conditions with detector removal facility also provided as standard.

The cabinet will house 2 x 12V 2.1AH S.L.A. batteries wired in series, which will sustain an 8 zone panel for up to 24 hours. All panels have a zone 1 non-latch facility to enable panel interlinking without “lock-up” occurring. The class change input enables the alarm circuits to operate without panel indication or panel latching.

The cabinet back box houses only the transformer, thus providing a virtually empty enclosure for first fix installation. A steel gland plate, removable plastic grommets and ample space are designed to assist with cable termination. A slide-in insert is included for a clear zone identification. The surface mount electronics motherboard is fitted and terminated after first fix installation. Finally a terminal cover completes the panel installation.

The 4 & 8 zone panels will accomodate up to 3 repeater panels, which are connected by a shielded 2 core data cable where the repeater panels are powered locally, or an additional 2 core may be run from the panel for power (max 1 repeater may be powered from the panel).

Features

Built in detector removal indication facility

From 1 to 8 zones

4 Alarm circuits on 4-8 zone panels

Conforms to the requirements of EN54-2

User friendly access code

one-man test facillity

Non-latching zone feature

Class change input

Earth fault monitoring

Fully functional repeater available (4 & 8 zone panels only)

Removable cable entry grommets

User friendly controls

Surface or semi-flush mounting as standard

Ample termination space

Flame restant polycarbonate enclosure

Log book and manual supplied

Complies with SMC and LVD directives