//Discovery 6 Loop Analogue Addressable Control Panel

Discovery 6 Loop Analogue Addressable Control Panel

From 5-8 Loops

LPCB approved to EN54 parts 2 & 4

Full Apollo XP95 and Discovery compatibility

Automatic recognition of Apollo or CEL outstations

Extensive mode change options by day/night and special group allocation

Windows based, full upload/download PC software package

500mA output per loop with highly stable voltage platform, even under mains failed conditions

Fully networkable with other Discovery and Voyager panels, graphics package and Integra network repeaters

Powerful processing and extensive panel and loop I/O capability

User friendly controls and clear, unambiguous screen

Membrane facia with tactile switches

Complies with EMC and LVD Directives

32 or 96 zonal fire and fault led indications

SKU: FireAlarmPanel394 Category: Tag:

Description

Please Note: due to regulation issues this product is now obsolete. We recommend using the Advanced MX-5806 as a suitable alternative.

Discovery 6 Loop Analogue Addressable Control Panel (XP95 & Discovery Protocols)

The Discovery analogue addressable panels are a powerful yet user friendly series of control panels. They are designed to a high standard with LPCB approval to EN54, parts 2 & 4. Each panel in this modular series has considerable processing ability but is easy to install, programme and operate. This is supported by comprehensive support documentation. Panels are housed in steel enclosures and are finished in hardwearing epoxy paint.

This panel is ideally suited to installations which require very complex sounder and control/shutdown functions. The panels are programmable to meet individual site requirements by means of a cause and effect matrix. This is downloaded from a PC, using the Cause & Effect Edit Programme. Text may be edited via a keyboard or downloaded from a PC.

The Discovery has a 4 line x 20 character backlit LCD display, showing the first and most recent event. Other events may be reviewed using the more messages facility. User controls are accessed by means of keyswitch enabled membrane controls, with password protection for engineer purposes. Each panel has a high level of processing power and each loop has its own processor. The panel allows up to 126 addresses per loop. All addresses on a loop may be used for output functions, with 3 independently programmable output bits per address.

By using Apollo Discovery detectors, the system may be configured to automatically switch between heat and smoke detection at selected times of day or week. Additional facilities are also provided for temporary switching between smoke and heat detection to suit short term changes in enviromental conditions.

Up to 248 user definable panel inputs and relay/two stage alarm outputs can be provided via expansions boards. Many useful testing and service functions are also provided. All events may be recorded on the optional printer and 32 zonal indications are included as standard with an option for 96 zonal indications. There is a complete range of compatible accessories available to support the Discovery panels to meet most customer requirements. The addition of a network card to the panel will allow monitoring, indication and control of the functions of a networked installation, allowing signals to be distributed around a large site.

Features

From 5-8 Loops

LPCB approved to EN54 parts 2 & 4

Full Apollo XP95 and Discovery compatibility

Automatic recognition of Apollo or CEL outstations

Extensive mode change options by day/night and special group allocation

Windows based, full upload/download PC software package

500mA output per loop with highly stable voltage platform, even under mains failed conditions

Fully networkable with other Discovery and Voyager panels, graphics package and Integra network repeaters

Powerful processing and extensive panel and loop I/O capability

User friendly controls and clear, unambiguous screen

Membrane facia with tactile switches

Complies with EMC and LVD Directives

32 or 96 zonal fire and fault led indications

Discovery 5-8 Loop is in a double door enclosure and consists of 2 x Discovery panels networked together, 480h x 820w x 144d.

Please choose options from the drop down box; Please Note: due to regulation issues this product is now obsolete. We recommend using the Advanced MX-5806 as a suitable alternative.

Discovery 6 Loop Analogue Addressable Control Panel (XP95 & Discovery Protocols)

The Discovery analogue addressable panels are a powerful yet user friendly series of control panels. They are designed to a high standard with LPCB approval to EN54, parts 2 & 4. Each panel in this modular series has considerable processing ability but is easy to install, programme and operate. This is supported by comprehensive support documentation. Panels are housed in steel enclosures and are finished in hardwearing epoxy paint.

This panel is ideally suited to installations which require very complex sounder and control/shutdown functions. The panels are programmable to meet individual site requirements by means of a cause and effect matrix. This is downloaded from a PC, using the Cause & Effect Edit Programme. Text may be edited via a keyboard or downloaded from a PC.

The Discovery has a 4 line x 20 character backlit LCD display, showing the first and most recent event. Other events may be reviewed using the more messages facility. User controls are accessed by means of keyswitch enabled membrane controls, with password protection for engineer purposes. Each panel has a high level of processing power and each loop has its own processor. The panel allows up to 126 addresses per loop. All addresses on a loop may be used for output functions, with 3 independently programmable output bits per address.

By using Apollo Discovery detectors, the system may be configured to automatically switch between heat and smoke detection at selected times of day or week. Additional facilities are also provided for temporary switching between smoke and heat detection to suit short term changes in enviromental conditions.

Up to 248 user definable panel inputs and relay/two stage alarm outputs can be provided via expansions boards. Many useful testing and service functions are also provided. All events may be recorded on the optional printer and 32 zonal indications are included as standard with an option for 96 zonal indications. There is a complete range of compatible accessories available to support the Discovery panels to meet most customer requirements. The addition of a network card to the panel will allow monitoring, indication and control of the functions of a networked installation, allowing signals to be distributed around a large site.

Features

From 5-8 Loops

LPCB approved to EN54 parts 2 & 4

Full Apollo XP95 and Discovery compatibility

Automatic recognition of Apollo or CEL outstations

Extensive mode change options by day/night and special group allocation

Windows based, full upload/download PC software package

500mA output per loop with highly stable voltage platform, even under mains failed conditions

Fully networkable with other Discovery and Voyager panels, graphics package and Integra network repeaters

Powerful processing and extensive panel and loop I/O capability

User friendly controls and clear, unambiguous screen

Membrane facia with tactile switches

Complies with EMC and LVD Directives

32 or 96 zonal fire and fault led indications

Discovery 5-8 Loop is in a double door enclosure and consists of 2 x Discovery panels networked together, 480h x 820w x 144d.

Please choose options from the drop down box