//Fireclass J424-8 8 Zone Conventional Fire Panel (Expandable up to 24)

Fireclass J424-8 8 Zone Conventional Fire Panel (Expandable up to 24)

EN54 approved

Optional extinguishing module EN12094-1 approved

8 zones mainboard

Supports 2 J400-EXP8 expander modules, for total 24 zones

Up to 32 devices can be connected to each zone

Gas zone compatible with 4-20 mA gas detectors

One alarm-repeat output (open collector) for each input zone

Manual call point recognition

Signals missing detectors

2 supervised, silence able, by passable 24 V alarm output for sounders

Silence able fault-warning output for the activation of signalling and auxiliary devices

Supervised fire output for telephone dialler activation

Programmable open-collector output

Dry contact alarm-relay for the activation of auxiliary devices

Day/Night mode

Alarm verification time

Programmable restoral and reset times

Programmable from PC or keypad

50 event log viewed via PC

Alarm/fault memory activated until next reset

Command for silencing sirens

Keypad commands require key or pin code

Repeater available

Optional backlit display

SKU: Conventional Panel34 Category: Tag:

Description

Fireclass J424-8 8 Zone Conventional Fire Panel (Expandable up to 24)

Designed and made according to EN54 standards, the J424 is a microprocessor based control panel for medium and large applications. It has 8 zones main board and supports two J400-EXP8 expander modules, for a total of 24 zones and 512 detectors. Each detection zone is equipped with an alarm repeat output for selective alarm management in the event of fire. The control panel has supervised and silence able alarm outputs for the control of the self-powered sirens, piezoelectric sirens, fire bells, flashers, telephone diallers, etc.

This easy-to-use control panel is protected by a lockable front plate which allows operational access to authorized personnel only. The J424 control panel is also available with a backlit display, which shows all the information regarding the control panel status. The optional Software in Windows™ environment, allows full systems management of events memory, files, reset and all the programmable functions provided by the control panel.

Key Features:

EN54 approved

Optional extinguishing module EN12094-1 approved

8 zones mainboard

Supports 2 J400-EXP8 expander modules, for total 24 zones

Up to 32 devices can be connected to each zone

Gas zone compatible with 4-20 mA gas detectors

One alarm-repeat output (open collector) for each input zone

Manual call point recognition

Signals missing detectors

2 supervised, silence able, by passable 24 V alarm output for sounders

Silence able fault-warning output for the activation of signalling and auxiliary devices

Supervised fire output for telephone dialler activation

Programmable open-collector output

Dry contact alarm-relay for the activation of auxiliary devices

Day/Night mode

Alarm verification time

Programmable restoral and reset times

Programmable from PC or keypad

50 event log viewed via PC

Alarm/fault memory activated until next reset

Command for silencing sirens

Keypad commands require key or pin code

Repeater available

Optional backlit display