//Global Fire Orion 4 Zone Conventional Fire Alarm Control Panel

Global Fire Orion 4 Zone Conventional Fire Alarm Control Panel

2, 4 and 8 Zone non-expandable control panels

Up to 32 conventional smoke and/or heat detectors per Zone

Active End of Line monitoring

Programmable non-latching Zones

Delay timer programmable on/off per Zone

Coincidence programmable for adjacent Zones

One man test

Supervised auxiliary 24 volt output

2 Supervised/ monitored sounder circuits

3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset

2 Relay outputs fire and fault

Fully EN54 part 2 and 4 compliant

Repeater output

Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)

Multiplexed output for sounders per zone (GFE-MPX-SNDR)

Addressable Loop Interface card (GFE-ADLI)

SKU: Conventional Panel42 Category: Tag:

Description

The ORION conventional control panel range offers a creatively designed and visually pleasing solution for smaller cost-conscious projects demanding simplicity of operation. Versions available include 2, 4 and 8 zone panels and two styles of repeater. The outstanding programmable features included in this panel range contradict the facilities commonly available

in this type of panel and include: programmable time delay by zone, Day/Night mode, selectable non-latching zones and coincidence detection. Operation is extremely intuitive, offering simple control and one-button disablement facilities, as well as the one man test mode which provides simple and efficient testing of the system.

Advanced configuration solutions include the following: a dedicated RS232 communication interface allowing connection of up to 4 remote repeater panels, addressable loop interface modules and multiplexed zonal output relays; giving one of the most highly advanced levels of system integration and compatibility existing on the market at this level.

Key Features:

2, 4 and 8 Zone non-expandable control panels

Up to 32 conventional smoke and/or heat detectors per Zone

Active End of Line monitoring

Programmable non-latching Zones

Delay timer programmable on/off per Zone

Coincidence programmable for adjacent Zones

One man test

Supervised auxiliary 24 volt output

2 Supervised/ monitored sounder circuits

3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset

2 Relay outputs fire and fault

Fully EN54 part 2 and 4 compliant

Repeater output

Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)

Multiplexed output for sounders per zone (GFE-MPX-SNDR)

Addressable Loop Interface card (GFE-ADLI)