//Kentec Sigma CP 2-Wire Fire Alarm Control Panel (2 – 8 Zone)

Kentec Sigma CP 2-Wire Fire Alarm Control Panel (2 – 8 Zone)

Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided).

Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4

2-wire and standard versions in 2, 4 or 8 zones

Compatible for use on BS5839: Part 1: 2002 installations

2-wire repeaters and ancillary boards

Fully programmable using simple menu options:; Simple, single board construction

Installer friendly

Compatible with wide range of detection devices

Two monitored sounder outputs

3 Amp power supply

Auxiliary power output

SKU: Conventional Panel84 Category: Tag:

Description

Sigma CP 2-Wire Fire Alarm Control Panel (2 – 8 Zone)

The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems – Control and Indicating Equipment. The range consists of 2, 4 and 8 zone control panels.

All control panels are available in two versions:

Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided).

Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.

Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. (T series only) All control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.

Key Features:

Fully certified to BS EN54-2 and BS EN54-4

2-wire and standard versions in 2, 4 or 8 zones

Compatible for use on BS5839: Part 1: 2002 installations

2-wire repeaters and ancillary boards

Fully programmable using simple menu options:

Adjustable sounder delay time

Sounder configuration options

Zonal sounder delay detectors only

Zonal sounder delay call points only

Coincidence input selection

I.S Barrier selection by zone

Short circuit fire by zone

Non latching zones

Silent zones

Zone input delay

General panel configuration

Simple, single board construction

Installer friendly

Compatible with wide range of detection devices

Two monitored sounder outputs

3 Amp power supply

Auxiliary power output

Part Number:

Description:

T11020M2

Sigma CP Two Wire Panel, 2 Zones: Surface

T11040M2

Sigma CP Two Wire Panel, 4 Zones: Surface

T11080M2

Sigma CP Two Wire Panel, 8 Zones: Surface