//Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire Panel (2 – 8 Zone)

Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire Panel (2 – 8 Zone)

2 wire systems, reduces installation cabling

2-wire repeaters and ancillary boards via serial bus

Fully programmable using simple menu options

Adjustable sounder delay time

Sounder configuration options

Zonal sounder delay for detectors only

Zonal sounder delay for call points only

Coincidence output via ancillary board

Short circuit fire selectable by zone

Non latching selection by zone

Silent zones (common sounder outputs)

Zone input delay for sprinkler system connection

AlarmSense® local alarm feature supported

Simple, single board construction

Installer friendly

Compatible with all AlarmSense® devices

Two conventional monitored sounder outputs

3 Amp power supply

Auxiliary power output

Fully certified to BS EN54-2 and BS EN54-4

Allows systems to be installed in accordance with BS5839: Part 6

SKU: Conventional Panel91 Category: Tag:

Description

Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire Panel

The Sigma CP-A AlarmSense® range consists of a series of conventional, two, four and eight zone fire alarm control panels. The AlarmSense system enables all detection and sounder devices in a given zone to be wired to the same pair of cables, greatly reducing the cabling and installation requirements and hence costs.

The AlarmSense range of devices includes smoke and heat detectors, call points, base sounders, base sounder/beacons and relay units – all wired to the same pair of cables. Having sounders and sounder beacons installed on the same cabling as detectors and call points allows all systems to be configured for common, zonal or two-stage alarms by simply setting one of the panels configuration options.

Selection of the AlarmSense local alarm feature at sounder or sounder beacon bases invokes the alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm mode, alarms are restricted such that only the sounder connected to the activated detector will operate initially.

The panel will attempt to reset the activated detector after a time delay and if successful no further alarms are sounded. If the detector re-activates after being reset, a general alarm will sound throughout the premises. The alarm verification feature of the Sigma CP-A control panel greatly reduces the risk of unwanted alarms or call outs while still providing secure, high quality fire protection throughout the premises.

Key Features:

2 wire systems, reduces installation cabling

2-wire repeaters and ancillary boards via serial bus

Fully programmable using simple menu options

Adjustable sounder delay time

Sounder configuration options

Zonal sounder delay for detectors only

Zonal sounder delay for call points only

Coincidence output via ancillary board

Short circuit fire selectable by zone

Non latching selection by zone

Silent zones (common sounder outputs)

Zone input delay for sprinkler system connection

AlarmSense® local alarm feature supported

Simple, single board construction

Installer friendly

Compatible with all AlarmSense® devices

Two conventional monitored sounder outputs

3 Amp power supply

Auxiliary power output

Fully certified to BS EN54-2 and BS EN54-4

Allows systems to be installed in accordance with BS5839: Part 6

Variants Available:

Part Number:

Description:

KA11020M2

Sigma CPA Alarmsense Conventional Panel, 2 Zones: Surface

KA11040M2

Sigma CPA Alarmsense Conventional Panel, 4 Zones: Surface

KA11080M2

Sigma CPA Alarmsense Conventional Panel, 8 Zones: Surface