//Kentec Sigma CP Conventional Fire Control Panels with LCMU (2-8 Zone)

Kentec Sigma CP Conventional Fire Control Panels with LCMU (2-8 Zone)

“Two-wire and standard versions in two, four or eight zones

Compatible for use on BS5839: Part 1: 2017 installations

Two-wire repeaters and ancillary boards

Simple, single board construction

Compatible with wide range of detection devices

Two monitored sounder outputs

Three Amp power supply

Auxiliary power output

Fully certified to BS EN54-2 and BS EN54-4

Fully programmable using simple menu options

Adjustable sounder delay time

Sounder configuration options

Zonal sounder delay detectors only

Zonal sounder delay call points only

Coincidence input selection

I.S Barrier selection by zone

Short circuit fire by zone

Non latching zones

Silent zones

Zone input delay

General panel configuration”

SKU: Conventional Panel60 Category: Tag:

Description

“Kentec Sigma CP Conventional Fire Control Panels with LCMU (2-8 Zone)

The Sigma CP range of conventional fire control panels are designed for the most demanding of conventional fire detection and alarm system applications.

Easy to install, the Sigma CP is available with two, four or eight detection zones in standard or installation saving, ‘two wire’ versions. The extensive range of configuration features available ensure suitability for new installations or panel replacements on older systems.

Configuration options are stored in non-volatile memory and are easily accessed via an intuitive user interface, which enables the configuration data to be viewed and changed efficiently.

Sigma CP control panels are compatible with most standard, conventional detectors, call points and sounders and are also compatible with ‘two wire’ detector bases from Apollo and Hochiki.

Key Features

Two-wire and standard versions in two, four or eight zones

Compatible for use on BS5839: Part 1: 2017 installations

Two-wire repeaters and ancillary boards

Simple, single board construction

Compatible with wide range of detection devices

Two monitored sounder outputs

Three Amp power supply

Auxiliary power output

Fully certified to BS EN54-2 and BS EN54-4

Fully programmable using simple menu options

Adjustable sounder delay time

Sounder configuration options

Zonal sounder delay detectors only

Zonal sounder delay call points only

Coincidence input selection

I.S Barrier selection by zone

Short circuit fire by zone

Non latching zones

Silent zones

Zone input delay

General panel configuration

Product Codes

Description

KL11020M2

Sigma CP Conventional Panel, 2 Zones: Surface including LCMU

KL11040M2

Sigma CP Conventional Panel, 4 Zones: Surface including LCMU

KL11080M2

Sigma CP Conventional Panel, 8 Zones: Surface including LCMU”