Protec ProPoint PLUS Aspirating Smoke Detector

1 – 4 Individual detectors per aspirator (providing up to 4 separately identifiable areas)

High performance optical ‘Scatter Chamber Detectors’ (SCD) or High performance optical ‘Scatter Chamber Detectors’ (SCD) and enhanced CO detection

Multiple language, multi-function LCD display

Simple install and commission process without the need for a laptop connection

Simple Class A, Class B, Class C and Prison sensitivity configuration set up

Inbuilt algorithm to avoid unwanted alarms

Airflow monitoring per pipe; Class A – High Sensitivity Applications include: Small Computer Rooms, Cleanrooms, Data Centres, Control Rooms, Archive Storage & EDP areas

Class B – Enhanced Sensitivity Applications include: Small Historic Buildings, Museums, Theatres, Galleries, High Ceiling Areas, Small Clean Warehouses & Small Atria Areas

Class C – Normal Sensitivity and Harsh Environment Applications include: Lift/Elevator Shafts, Small Cold Storage Facilities, Clean Warehouses, Atria, Inaccessible Voids & Up to 4 x separately identifiable Prison Cells per aspirator.

SKU: asddetect79 Category: Tag:

Description

Protec ProPoint PLUS Aspirating Smoke Detector

Aspirating detection is now a recognised solution for many different fire detection applications. ProPoint PLUS provides up to four separate detectors within a common aspirator enclosure and therefore provides four individually identifiable areas of detection per aspirator. Each of the four plug-in ‘Scatter Chamber Detectors’ (SCD)’s detector modules can be either ‘optical’ only or combined.

‘optical/enhanced CO’ detectors for small single room applications. Independent and integrated alarm decision making through the use of complex algorithms extend the range of particle detection, confirm genuine alarms and reduce unwanted alarms. Installation, configuration and commissioning of ProPoint PLUS detectors is very simple and installer friendly. Configuration to either Class A, Class B or Class C sensitivity options is achieved through a multi-language, multi-function LCD display without the need for a laptop connection.

Detector set up allows the installer to configure the detector sensitivity to exactly the same equivalent as a known number of point type smoke detectors for each Class A, Class B and Class C system. This ensures the system specifier, designer, installer and commissioning engineer configure the ProPointPlus SCD’s to the correct sensitivity for the particular application. Aspirator fan speed and airflow configuration is an also a very simple process allowing ProPointPlus aspirating detectors to be installed in a variety of applications with short and relatively long pipe runs.

Key Features:

1 – 4 Individual detectors per aspirator (providing up to 4 separately identifiable areas)

High performance optical ‘Scatter Chamber Detectors’ (SCD) or High performance optical ‘Scatter Chamber Detectors’ (SCD) and enhanced CO detection

Multiple language, multi-function LCD display

Simple install and commission process without the need for a laptop connection

Simple Class A, Class B, Class C and Prison sensitivity configuration set up

Inbuilt algorithm to avoid unwanted alarms

Airflow monitoring per pipe

Application Guide:

Class A – High Sensitivity Applications include: Small Computer Rooms, Cleanrooms, Data Centres, Control Rooms, Archive Storage & EDP areas

Class B – Enhanced Sensitivity Applications include: Small Historic Buildings, Museums, Theatres, Galleries, High Ceiling Areas, Small Clean Warehouses & Small Atria Areas

Class C – Normal Sensitivity and Harsh Environment Applications include: Lift/Elevator Shafts, Small Cold Storage Facilities, Clean Warehouses, Atria, Inaccessible Voids & Up to 4 x separately identifiable Prison Cells per aspirator.