//Talentum Triple IR Flame Detector 16519

Talentum Triple IR Flame Detector 16519

Fire/Fault, Pre-alarm

Relay Contacts;

Latching or Non-latching

4-20mA

[Zones 1, 21, 2 and 22]

Ex tb IIIC T135°C Db IP66 A21

II 2GD Ex d IIC T4 Gb

ATEX & IECEx certified

Class 1 Sensitivity to EN54-10 Detects 0.1m² fire @ 25m

Excellent Optical Interference Immunity

Selectable Output Options:

Conventional 2 wire

Selectable Response Speed

Optical Self Test

Low Power Consumption

LPCB & CPD Approved to EN54-10; Flame Detector – Data Sheet

Flame Detector – EXD Installation Guide

Flame Detector – User Manual

Flame Detector – Maintenance Guide

Flame Detector – IS Installation Guide

Distance Sensitivity of the Talentum Flame Detector

What flame detector should I choose?

What types of flames can Talentum detect?

SKU: convhazard409 Category: Tag:

Description

Talentum Triple IR Flame Detector 16519

The sensor responds to low-frequency (1 to 15 Hz) flickering IR radiation emitted from flames during combustion. IR flame flicker techniques enable the sensor to operate through a layer of oil, dust, water vapour, or ice. Most other IR flame sensors respond to 4.3?m light, emitted by hydrocarbon flames. By responding to 1.0 to 2.7?m light emissions from fires almost all flickering flames can be detected.

Gas fires not visible to the naked eye e.g. hydrogen may also be detected. The triple IR photoelectric detectors (IR³), responding to neighbouring IR wavelengths, enable it to discriminate between flames and spurious sources of IR radiation. The combination of filters and signal processing allows the sensor to be used with a very low risk of false alarms in difficult situations characterised by factors such as flickering sunlight.

Key Features:

Fire/Fault, Pre-alarm

Relay Contacts;

Latching or Non-latching

4-20mA

[Zones 1, 21, 2 and 22]

Ex tb IIIC T135°C Db IP66 A21

II 2GD Ex d IIC T4 Gb

ATEX & IECEx certified

Class 1 Sensitivity to EN54-10 Detects 0.1m² fire @ 25m

Excellent Optical Interference Immunity

Selectable Output Options:

Conventional 2 wire

Selectable Response Speed

Optical Self Test

Low Power Consumption

LPCB & CPD Approved to EN54-10; Flame Detector – Data Sheet

Flame Detector – EXD Installation Guide

Flame Detector – User Manual

Flame Detector – Maintenance Guide

Flame Detector – IS Installation Guide

Distance Sensitivity of the Talentum Flame Detector

What flame detector should I choose?

What types of flames can Talentum detect?