//Tyco LPAV800-R L/P Symphoni Sounder/Beacon (Indoor Use) Red

Tyco LPAV800-R L/P Symphoni Sounder/Beacon (Indoor Use) Red

Loop Powered – Reduced installation costs

High Output/Low consumption – Lower lifetime costs

Indoor and Outdoor models – Same sounder tones in all areas

Sounder/LED Beacon Version – DDA Compliant

16 Tones and 2 Flash rates – Suits individual requirements

Reflective Sound Monitoring RSM – Reassurance that ALL sounders are working

Integral Line Isolator – Saves cost and installation time; Models Available

SKU: Addressable Audio Visual27 Category: Tag:

Description

LPAV800-R L/P Symphoni Sounder/Beacon (Indoor Use) Red

Features

Loop Powered – Reduced installation costs

High Output/Low consumption – Lower lifetime costs

Indoor and Outdoor models – Same sounder tones in all areas

Sounder/LED Beacon Version – DDA Compliant

16 Tones and 2 Flash rates – Suits individual requirements

Reflective Sound Monitoring RSM – Reassurance that ALL sounders are working

Integral Line Isolator – Saves cost and installation time

Models Available

The sounder only models are available with a red or white housing suitable for indoor use and an IP65 rated red housing for outdoor applications.

The audio/visual models, which incorporate a highly efficent LED beacon, are also available with a red or white housing for indoor use and an IP65 rated red housing for other outdoor applications.

Up to now sounder circuits have been monitored up to the EOL but not the individual sounders, fault detection has relied on human feedback from the weekly tests that should be carried out to meet the requirements of BS5839.

The LP Symphoni utilising Reflective Sound Monitoring (RSM) employs a transducer to actively monitor the units sound output during the weekly sounder test and will report back to the MX controller if it fails to detect the sounder operating when it has been commanded to, this ensures that the LP Symphoni range of sounders will in the unlikly event of a fault, display it immediately on the fire controller and is therefore not dependant upon the staff within a building reporting a sounder failure.

Built-in Isolation

As the line isolator is now integral to the device the need for separate line isolation devices is reduced.

Tones

16 Tones are available from the sounder, which include tones compatible with the 802SB sounder base and the LPBB520 (Loop Powered Besson Banshee). Dutch slow whoop and the DIN 1Hz sweep are included. Two sound levels 103dB & 90dB.

MX Consys

The LP symphoni range of devices will be fully supported by Consys V10 and later, the point input dialog box provides and easy method for setting the tones, volume and flash rate of the device. The only operation required at the device is to set the address using the 801AP device programmer.