Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences Automatic adaptation to varying environmental influences Electronic compensation of long-term influences of contamination or aging -
Key Features:; 3 continuously or pulsed LEDs Power-saving compact indicator -
Gent Conventional Relay Detector Base 805591; Provides a voltage-free contact controlled by the remote output of a detector Draws negligible current A lot of space for wire connection Automatic closing of the loop bus wiring system for detector extraction Detector extraction locking is enclosed in the base -
Key Features:; Ease of installation and a lot of space for wire connection Slide-easy base and elegant design with automatic closing of the loop bus wiring system for detector extraction Detector extraction locking is enclosed in the base One-way only fit -
-
-
Very low power consumption means more sounders per loop e.g. 200 system sounders per loop compared to 40 The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power The strobe element of the sounders is fully monitored for circuit failures The sounder tones are programmed in exactly the same way as the existing Vigilon sounders Loop powered voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard By using the bell sound in the voice sounder it is possible to have a loop powered bell The sound producing element in the voice sounders is monitored every hour using a VLF tone Voice and Tone mode can be freely mixed within the same sounder All messages and strobe signals are synchronised across loops in the same control panel Complements the S-Quad sensor with voice messages and complex sound signals A backwards compatible version of the system sounder is available for replacement or expansion to existing systems, avoiding the need to upgrade panel software The HandiLink remote control makes it much easier to adjust the sounders in situ Products incorporate innovative design features for which multiple patents are pending High intensity flashing strobe conforms to the Disability Discrimination Act (DDA) 1995 legislation -
Very low power consumption means more sounders per loop e.g. 200 system sounders per loop compared to 40 The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power The strobe element of the sounders is fully monitored for circuit failures The sounder tones are programmed in exactly the same way as the existing Vigilon sounders Loop powered voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard By using the bell sound in the voice sounder it is possible to have a loop powered bell The sound producing element in the voice sounders is monitored every hour using a VLF tone Voice and Tone mode can be freely mixed within the same sounder All messages and strobe signals are synchronised across loops in the same control panel Complements the S-Quad sensor with voice messages and complex sound signals A backwards compatible version of the system sounder is available for replacement or expansion to existing systems, avoiding the need to upgrade panel software The HandiLink remote control makes it much easier to adjust the sounders in situ Products incorporate innovative design features for which multiple patents are pending High intensity flashing strobe conforms to the Disability Discrimination Act (DDA) 1995 legislation -
-
-
-
-
Key Features:; Max Quantity per Loop – 100 Approx Weight – 0.34kg Operating Temperature – minus 10C to +50C Ingress Protection – IP40 Device Load Factor – 1 -
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software -
High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-HD - Data Sheet F-Guard UV-IR-HD - Operators Manual -
High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-F-HD - Data Sheet F-Guard UV-IR-F-HD - Operators Manual -
Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; FLS-UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range FLS-UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR-F - Data Sheet F-Guard UV-IR-F - Operators Manual -
Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR - Operators Manual F-Guard UV-IR - Data Sheet -
High immunity to false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire=High immunity to false alarm Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosion 1.2 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance HD video output with Automatic HD video recording of fire events. Data/Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-HD - Data Sheet F-Guard IR3-HD - Operators Manual -
High immunity to false alarm Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions Hydrogen flame detection High sensitivity -up to 100 ft.(30m) HD video output with Automatic HD video recording of fire events Data/Event logger -alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-H2-HD - Data Sheet F-Guard IR3-H2-HD - Operators Manual -
Key Features:; High immunity to a false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosions 1.3 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance Data/Event logger -alarms, faults, and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3 - Data Sheet F-Guard IR3 - Operators Manual -
Features; LPCB 3rd party approved Low profile design 360° viewable LED design Removable detector chamber for cleaning Common mounting base New enhanced detectors feature Drift compensation and Chamber monitoring (FXN533 & FXN632) -
Features:; LPC approved Low profile design Locking facility 360O viewing angle LED -
Quick and simple to install Stylish low profile design 360º viewable LED Removable detector chamber Drift compensation