/All Products
  • Klaxon Syrex Exd Bell ATEX 110v AC - TCA-0003 (17-970233); Rated for Category 2 use (formerly Zone 1 & 2) ATEX approved II 2G Exd e IIC T6 Clear audible signal designed to penetrate background noise Weatherproof to IP66 Rugged construction Choice of voltages; Syrex Bell - Data Sheet
    Details
  • Rated for Category 2 use (formerly Zone 1 & 2) ATEX approved II 2G Exd e IIC T6 Clear audible signal designed to penetrate background noise Weatherproof to IP66 Rugged construction Choice of voltages; Syrex Bell - Data Sheet
    Details
  • Rated for Category 2 use (formerly Zone 1 & 2) ATEX approved II 2G Exd e IIC T6 Clear audible signal designed to penetrate background noise Weatherproof to IP66 Rugged construction Choice of voltages; Syrex Bell - Data Sheet
    Details
  • Klaxon Syrex Exd Buzzer ATEX 110v AC - TCA-0069 (17-970235); Rated for Category 2 use (formerly Zone 1 & 2) ATEX approved II 2G Exd e IIC T6 Heavy duty buzzer Weatherproof to IP66 Rugged construction; Syrex Buzzer - Data Sheet
    Details
  • Key Features:; Rated for Category 2 use (formerly Zone 1 & 2) ATEX approved II 2G Exd e IIC T6 Heavy duty buzzer Weatherproof to IP66 Rugged construction; Syrex Buzzer - Data Sheet
    Details
  • Key Features:; Rated for Category 2 use (formerly Zone 1 & 2) ATEX approved II 2G Exd e IIC T6 Heavy duty buzzer Weatherproof to IP66 Rugged construction; Syrex Buzzer - Data Sheet
    Details
  • Rated for Zone 0, 1 & 2 use ATEX approved II 1G EEx ia IIC T4 ABS flame retardant UL94V0 & 5VA housing Weatherproof to IP65; Syrex IS - Instructions Syrex IS - Data Sheet
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Robust Corrosion Resistant GRP body High Power (5 Joule) Certificated Flameproof; Voltage: 24Vdc Tube Energy: 5 Joules Peak Current Consumption (mA): 320 Effective Intensity (Cd): 29 Peak Intensity (Cd): 22213 Power Consumption (Watts): 8 Note: The Cd figures are for a clear lens @ 1Hz flash rate. For red lens multiple by 0.15 Weight: 2.5Kg Certified Temperature: EExd -55°C to + 70°C (T4) -55°C to + 55°C (T5) -55°C to + 40°C (T6) Ingress Protection: IP66 & IP67 Terminals: 6 x 2.5mm2 Entries: 2 x 20mm ISO EExd. Certification: BASEEFA EExd IIB 135°C (-55 to AMB +70°C)T4 100°C (-55 to AMB + 55°C)T5 85°C (-55 to AMB + 40°C)T6 Cert. No. 99 ATEX 2195X. CENELEC EN50014 and EN50018 Material Body: Glass reinforced polyester Lens: Glass Cover Screws + Backstrap: Stainless steel 316 Finish: Red
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 For use in hazardous areas Robust GRP construction Powerful Output, up to 118dBA; Terminals: 6 x 2.5mm2 Mounting: Stainless steel bracket with ratchet facility Cable Entries: 2 x 20mm EExd. Tone Selection: 27 user selectable tones. Certification: CENELEC EN50014,18,19 BASEEFA Cert. No. BAS00ATEX2097X, EExd IIC. Zones 1 and 2. Material: Body & horn in anti-static, UV stable, glass reinforced polyester. Swivel bracket & captive cover screws in stainless steel. Nominal Output (dBA) Input Current (mA)* 93 50 105 100 108 150 111 200 112 250 114 300 115 350 118 380 Product Code 576.501.049 Flameproof Horn Sounder (DB3D048N2BNR) Output measured with 24VDC input voltage. Tone set to 970Hz continuous. Weight: 6.0kg approx Ingress Protection: IP66 / IP67 Voltage: 12VDC to 48VDC Certified Temperature: -20o C to +70o C
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) Suitable for use in Zone 0,1 & 2 Robust GRP Body Suitable for offshore and petrochem Certificated Intrinsically Safe; Certification: CENELEC EN50014, 20 & 39 BAS02ATEX1258X EExia IIB T4 Zones 0,1 & 2 Material: UV stable glass reinforced polyester body. Clear polycarbonate cover/lens. Retained stainless steel cover screws. Finish: Painted Red Tube Type: Xenon discharge Lens Colour: Clear Terminals: 8 x 2.5mm2 Flash Rate: 1 flash per second Cable Entries: Up to 3 x M20 via knockouts Tube Energy: 0.5 Joules Weight: 1.4kg Certified Temperature: -55°C to + 60°C Ingress Protection: IP66 & IP67 Tube Life: >1 x 106 Flashes Voltage: 24V via suitable barrier Current Consumption: 71mA max nominal
    Details
  • ATEX approved EEx ia IIC T4 rating 49 Tones user selectable Automatic syncronisation Surface mount Volume control IP65; Intrinsically Safe Sounder - Data Sheet
    Details
  • ATEX approved EExd IIC T4 rating 32 Tones user selectable 2nd and 3rd stage alarm IP67 High output; Hazardous Area Sounder - Data Sheet
    Details
  • Features; ATEX approved EEx ia IIC T4 rating IP65 High efficiency LED's; Intrinsically Safe LED Beacon - Data Sheet
    Details
  • Ziton FA375 Hazardous Area Xenon Beacon; ATEX approved EExd IIC T6 rating IP67 5J Xenon Lens guard; Hazardous Area Xenon Beacon - Data Sheet
    Details
  • Key Features; ATEX certified IECEx certified GOST-R certified for Zone 0 applications FM certified for Class I Division 1 and Class I Zone 0 applications; Apollo I.S. Sounder - Data Sheet
    Details
  • Key Features; ATEX certified IECEx certified GOST-R certified for Zone 0 applications FM certified for Class I Division 1 and Class I Zone 0 applications; Intrinsically Safe Sounder Beacon - Data Sheet
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Technical Information C-Tec - Installation Guide
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma f Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Technical Information C-Tec - Installation Guide
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Technical Information C-Tec - Installation Guide
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma f Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Technical Information C-Tec - Installation Guide
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma f Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Installation Guide
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma f Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Installation Guide
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma f Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Installation Guide
    Details
  • Approved by ATEX, IECEx Group I MI Ex ia I Ma f Group II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C Da Zones 0, 1, 2, 20, 21 & 22 Conforms to: EN 60079-0:2012 + All:2013 (IEC 60079-0:2011) EN-60079-11:2012 + (IEC 60079-11:2011) Diode Polarised & End of line resistor compatible White base version available MOQ apply Dustproof & Weatherproof; C-Tec - LED Beacon - Datasheet C-Tec - Installation Guide
    Details
  • Zones 0, 1, 2, 20, 21 and 22 ATEX and IECEx approved IP66 rated Surface Mount Polycarbonate housing material; C-Tec - Electronic Sounder - Datasheet C-Tec - Installation Guide
    Details
  • Key Features:; 6” (152mm) Gong High sound output Low current consumption Low frequency aluminium gong Simple installation UL and FM approvals; Motorised Bell - Data Sheet
    Details
  • Key Features:; Housing Seawater resistant aluminium Used in hazardous areas of Zone 1 - Gas Used in hazardous areas of Zone 21 - Dust Flash blinking and rotation Internal or external use Suitable for use in the harshest of environments Long life, low maintenance light source High visibility with no glare; DsLB Beacon - Data Sheet
    Details
  • Key Features:; Housing Seawater resistant aluminium Used in hazardous areas of Zone 1 - Gas Used in hazardous areas of Zone 21 - Dust Flash blinking and rotation Internal or external use Suitable for use in the harshest of environments Long life, low maintenance light source High visibility with no glare; DsLB Beacon - Data Sheet
    Details
  • Cooper Fulleon Ex Signalling Bell dWG21 200mm Grey Gong Black Body (230 Vac) - F91230110; Exde, Zone 1 and Zone 2 use Output up to 105dB(A) GRP housing IP66 protection Suitable for explosion protected applications Suitable for use in high ambient noise levels Corrosion free low maintenance construction Internal or exposed external use; Signalling Bell - Data Sheet
    Details
  • Cooper Fulleon Ex Signalling Bell dWG21 200mm Grey Gong Black Body (24 Vdc) - F91024210; Exde, Zone 1 and Zone 2 use Output up to 105dB(A) GRP housing IP66 protection Suitable for explosion protected applications Suitable for use in high ambient noise levels Corrosion free low maintenance construction Internal or exposed external use; Signalling Bell - Data Sheet
    Details
  • Key Features:; For use in Zone 22 areas 5j flash IP54 protection Corrosion resistant Specially approved for use in hazardous dust environments Bright beacon for general signalling Can be used internally or externally Low maintenance; Strobe Light - Data Sheet
    Details
  • Key Features:; For use in Zone 22 areas 5j flash IP54 protection Corrosion resistant Specially approved for use in hazardous dust environments Bright beacon for general signalling Can be used internally or externally Low maintenance; Strobe Light - Data Sheet
    Details
  • Key Features:; Sleek modern aesthetics and styling Easy installation Voltage test points for quick troubleshooting and easy spot checking Prewire capability to check for wiring & ground faults prior to appliance installation; Strobe - Data Sheet
    Details
  • Key Features:; Sleek modern aesthetics and styling Easy installation Voltage test points for quick troubleshooting and easy spot checking Prewire capability to check for wiring & ground faults prior to appliance installation; Ceiling Mount - Data Sheet
    Details