Key Features:; Solar Blind for false alarm free operation Marine approved Fast response to flame Detect a 0.1m2 fire at a range of 20m Discrete ultra-low profile design Fits a standard detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors -
Features; Manufactured to EN54 part 3 Integral sounder and detector base Volume and tone adjustable after installation Low Power Synchronisation Do not require use of a standard base (maybe installed directly onto a standard besa box) -
Heat only detector (A1R or A2S) (no sensitivity selection) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)combined with heat (A1R) Carbon Monoxide Detector (sensitivity: High, Normal or Low); ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices -
Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Automatic health check feature Discrete ultra low profile design Fits a standard MX detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors -
ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices -
Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) -
-
The mode of detector may be:; Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) These detectors are designed to comply with EN/IEC 60079-0:2006, EN/IEC 60079-11:2007 and EN/IEC 61241-11:2006 for intrinsically safe apparatus; ATEX Code: Ex II 1GD Cenelec Code: Ex ia IIC T5/Ex iaD 20 T100oC -
PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating two MX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card(s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists firefighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems -
PSB800 5A 24Vd.c. battery backed power supply and loop booster FIM801CV field interface PCB incorporating one MX DIGITAL loop CPU800 32 bit processor and memory Card XLM800 loop expansion card containing two MX Digital loops Optional remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems -
Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems -
Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems -
Long term service and support Supports 1 MXDigital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 16 Zone Fully Functional Mains powered Repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839 Easy programming when using MXConsys Express configuration tool. -
Long term service and support Supports 1 MXDigital loop with 250 addresses 2 KM loop length 32 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 32 Zone Fully Functional Mains powered repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839 -
-
Intelligent Universal Smoke Detector Low profile, discreet and unobtrusive Superior performance and reliability Attractive new design Smart Card Addressing Technology Designed for fast easy installation Optional Locking Kit May be used in systems that meet BS5839 Pt1 Integral and remote alarm LED Wiring polarity independent LPCB approved to EN54 -
MUBEX Base Installation & Commissioning Instructions -
-
MX LPAV3000 Loop Powered Sounder/Beacon - Addressable Base; High output programmable sounder base and sounder beacon base One point of installation for detector, isolator, sounder & beacon Loop powered from the MX Technology® Digital Loop High brightness Multi-LED Beacon Software programmable 15 Tones and 2 Flash Rates Integral line isolator RSM (Reflective Sound Monitoring) Can be used as a standalone device using the sounder blanking cap -
Loop Powered - Reduced installation costs High Output / Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder / LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suites individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time -
Loop Powered - Reduced installation costs High Output / Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder / LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suites individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time -
PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating one MZX DIGITAL loop CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers BV, UL, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions -
EN54 Compliant MXDigital system Integral power supply Optional integral eighty way zonal LED’s Two to eight loops or network up to 396 loops 250 addresses per loop Full range of MZX virtual multi-sensor detectors MZX FASTLOGIC fuzzy logic smoke detection algorithms Fully functional repeater Powerful MXConsys & MXConsys Express configuration software Easy to install Space for 17Ah or 38Ah batteries -
FIM800 field interface PCB incorporating one or two MZX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers LPCB, BV, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions -
Continuous detection despite extremely large monitoring area Easy and rapid installation of the maintenance-free sensor cable Very high resistance to extremely contrary ambient influences(immune against heat, cold, humidity, corrosion, strong winds and draft) Undiminished precision under electromagnetic interference Unprecedented security against false alarms Very high sensor cable service life of up to 30 years Temperature profile over the complete measurement range delivers exact information of location, size and spreading of the fire Very low maintenance costs as the maintenance and the trouble shouting can be done from the control unit VdS certified to EN 54/5-A1 One controller unit will drive up two 8km spurs or one 8km loop Easy integration into existing installations Each sensor cable divided into up to 256 zones Individual configuration of 5 alarm criteria per zone Good network connection through Modbus, TCP/IP, FTP and SCPI interfaces -
Long term service and support Two way IR communications with Generation 6 Detectors reduces commissioning and service costs. Supports 1 MZX Digital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with “Front Panel Controls” to reduce lifetime cost of ownership Wide range of multi-sensor detectors including the 3oTec triple sensing detections. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 "Critical" Matching 16 Zone Fully Functional Mains powered Repeater Approved to EN54 the system is designed to be installed to BS5839 -
A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic conventional bell tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Replace legacy LPSB3000 and LPAV3000 -
A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for pre alarm and class change Aesthetically pleasing rectangle wall mount option A locking pin/screw supplied which prevents unauthorized removal -
A compact and discrete solution VAD approved to EN54-23 with two ranges, standard power and high power available High power option provides a larger VAD coverage volume compared to standard Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Automatic self-test Shorter light pulse for faster response Optimise the system design for lowest power requirements and lowest cost installation Triple light source One point of installation for detector, sounder and visual indicator with no additional wiring Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar. Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VADs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Provides an EN54-23 approved upgrade path for legacy systems -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Automatic self-test Shorter light pulse for faster response Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box for use with suitable IP-rated glands and cabling Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Automatic self-test Shorter light pulse for faster response Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box for use with suitable IP-rated glands and cabling Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic conventional bell tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Replace legacy LPSB3000 and LPAV3000 -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Automatic self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes Select the tone volume using panel configuration software Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for pre alarm and class change Aesthetically pleasing rectangle wall mount option A locking pin/screw supplied which prevents unauthorized removal -
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire; S200 Flame Detector - Data Sheet -
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire; Flame Detector - Data Sheet