  • Clear backlit alphanumeric / LED displays Compact size Loop powered, no separate supply required
    Details
  • Design certified to EN54 parts 2&4 1997, The SenTRI Four panel manages up to 4 loops up to 1km long, accommodating up to 200 devices on each loop. Can be upgraded to 72-hour standby The panel's software allows fire plans to be precisely tailored to site requirements Flexibility of design as up to 10 panels can be connected on a single network
    Details
  • Key Features:; Cost Effective Single Loop Panel High Capacity Loop – 192 Addresses Algo-Tec 6000Plus Protocol Surface and Recessed Mounting Easy to Install Reduced False Alarms Enhanced Performance On Site Flexibility Designed to EN54-2 & 4
    Details
  • High specification interactive digital addressable fire detection and alarm system, providing a cost effective solution for small, medium and large sized builds and sites Up to 32 control panels, repeats and illuminated zonal mimics can be networked enabling system design and expansion to be easily achieved to suit the site for economic wiring and operational convenience Wires as a loop, the network’s dual channel RS485 link ensures no single fault will affect the system An extensive range comprising loop powered alarm sounders, beacons, interfaces, manual call points and sensors can all be connected to the nearest control panel using a single 2-core cable for each of the high capacity loops (up to 4), accommodating up to 191 devices per Loop, 512 maximum per panel.
    Details
  • Key Features:; Distributed network of display and control nodes (DCN’s) and loop processing nodes (LPN’s) providing a cost effective solution for medium and large sized buildings and sites Wires as a loop, the network’s dual channel RS485 link ensures that no single fault will affect the system Alarm sounders, beacons, interfaces, manual call points and sensors can all be loop powered The Protec Algo-Tec 6000 interactive fire sensor utilize advanced discrimination algorithms for maximum reliability and immunity to false alarms.
    Details
  • Low Power – The power consumption of the repeater has been minimised through energy efficient design, preserving loop current and capacity. Quiescent 1.6mA, Alarm 12.7mA Installation – The repeater can be surface or flush mounted as standard, allowing gland or conduit entrance through the rear, top or bottom of the enclosure. The device only requires a loop connection to provide both power and data, no network cabling, or external power supply is required. Event Display – Events are categorised and clearly displayed for intuitive navigation of the system status, whilst large graphical indicators show a general system overview. User Assistance – A help menu displays a list of status specific tool-tips to aid the user in accomplishing tasks, such as silencing the internal buzzer or performing a lamp test. If the user requires additional help, the contact details for site engineers and the installer are available on the screen. Multi-Language Support – The 6000/LOOP/REPEATER’s graphical user interface caters for most Western European languages and Arabic script as standard. The language for event strings is inherited from the control panel. USB Configuration – The fast USB configuration tool allows the device to be programmed with site specific data, such as contact details for site engineers and the installer along with custom logos and settings.
    Details
  • Extended capacity:; The Pearl supports up to 636 loop devices (159 detectors plus 159 modules per loop) Longer loops, but fewer of them, will give the opportunity to save on installation time, cost and wiring Highly resilient Opal system, able to pinpoint a loop fault whilst maintaining full system operation Powerful networking capability - Up to 16 Pearl panels, controlling over 10,000 devices, can be networked via the superfast ID2net; prioritising a fire signal to communicate across a network in under three seconds; Intuitive on-site management - backlit buttons for fast, error free situation management, and large display giving complete information at a glance Simpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector status Text programming via MS Excel spread sheet User permissions set per individual password; Unique first fix bracket with adaptations for 19” rack or flush mounting. Fast system set up and commissioning via the panel, loop “Autolearn” and advanced PC tools suite Comprehensive “Cause & Effect” programming capability Panel sounder and beacon synchronisation System extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cabling Separate text change without risk to “Cause & Effect” or system configuration. Ability to run BS5839 part 6 system for HMO
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • 240 x 60 Graphic LCD H165mm x W254mm x D50mm Requires external power source
    Details
  • Extended capacity:; The Pearl supports up to 636 loop devices (159 detectors plus 159 modules per loop) Longer loops, but fewer of them, will give the opportunity to save on installation time, cost and wiring Highly resilient Opal system, able to pinpoint a loop fault whilst maintaining full system operation Powerful networking capability - Up to 16 Pearl panels, controlling over 10,000 devices, can be networked via the superfast ID2net; prioritising a fire signal to communicate across a network in under three seconds; Intuitive on-site management - backlit buttons for fast, error free situation management, and large display giving complete information at a glance Simpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector status Text programming via MS Excel spread sheet User permissions set per individual password; Unique first fix bracket with adaptations for 19” rack or flush mounting. Fast system set up and commissioning via the panel, loop “Autolearn” and advanced PC tools suite Comprehensive “Cause & Effect” programming capability Panel sounder and beacon synchronisation System extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cabling Separate text change without risk to “Cause & Effect” or system configuration. Ability to run BS5839 part 6 system for HMO
    Details
  • Key Features:; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 Loops 1 x 020-579 - 7A PSU 4.5A or 7A User selectable 1 x 020-543 - Dual transmittion path board kit 1 x 020-588 - Dual loop board kit 1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-485-009 - Extension cover blanking kit 1 x 020-481-009 - Extension cover kit
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 1 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 2 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1 x 020-474-009 - Extended deep back-box kit space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 3 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1x 020-548 - Optional status indicator board kit for 7A PSU 1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H:620mm W:500mm D:122mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer 1 x 020-541-009 - 7A PSU/78AH battery cabinet kit
    Details
  • Nexus Repeater Panel 24V Small Enclosure 2500834; Designed for use with Nexus analogue addressable control panels Style to match control panels Available in small cabinet (illustrated) or larger cabinet with zone LEDs and additional printer / equipment space 4 line x 20 character backlit LCD User friendly controls enabled by a keyswitch Unambiguous screen Membrane facia with tactile switches Panel or local mains powered RS485— 2 core data comms
    Details
  • 20 programmable zonal / 25 System LEDs Nittan Evolution protocol Graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware Dedicated USB & RS232 Serial Port for direct PC or modem connection Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding Graphical display configurable for virtually any language Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination Integral P-Bus for system expansion via available option cards Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2 and 4
    Details
  • Certified to EN54 parts 2 and 4 Up to 198 devices per loop (99 sensor and 99 modules) Expandable from 2 to 8 loop capacity Adjustable sensor sensitivity Drift compensation Inter link options Master / Slave Configurable day / night sensitivity adjustment Addressable device LED blink control Automatic or Manual “Loop Learn” options Automatic device “high test” at configured time of day “Walk Test” function by zone for efficient commissioning Configurable “walk test” time limit Auto-program option 600 event history file Duplicate address fault monitoring 2 optional user configurable communication ports Dual pulse rate capability for outputs Pulsing loop powered sounders capability with steady override Non-alarm non-latching addressable device support for lower priority functions Variety of Mounting options Automatic time control functions by day of week for “Control-by-Event” (CBE) Time of day and day of week exclusions for “CBE” Remote reset output capability for peripheral equipment Configurable rapid response from manual call points (less than 3 seconds) 80 Zone capacity per panel Zone sub-division to cells for “CBE” Coincidence detection configurable by zone or cell for “CBE” Fire and fault verification delays configurable by address Pre-defined device type characteristics Output device test activation by address Selective event log display or print by date and time Full configuration edit capability from panel or PC Multiple options for RS232 port protocol
    Details
  • From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • Features; From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • Features; From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • Features; From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • Designed to EN54: parts 2 and 4 PC based commissioning tools allow complex fire plans to be configured and flexible programming options are available at the panel. The control panel has a simple user interface with LCD screen providing accurate information in an emergency Networks of up to 10 panels can be programmed seamlessly as one system. 2 and 4 loop panels can be connected on the same network allowing flexibility of design In the event of a fire or fault, SenTRI's analogue addressable technology will provide a detailed log of events A built-in printer fitted to the SenTRI FOUR can be used to print out device configurations, loop maps and historic logs. A menu option is available to turn off the printer when a printed record is not required; The SMS SENTRI4-NC is a network card for the SenTRI 4 control panel Model: SENTRI4-NC Shipping Weight: 100gms
    Details
  • From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives
    Details
  • All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
    Details
  • All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
    Details
  • Nano is compatible with Gent’s range of loop powered devices. All devices connect onto the same two core loop, separate sounder wiring circuits are not required. Nano drives advanced detection technology including the full S-Quad range. A building’s fire plan can be configured either at the Nano panel or through the simple PC commissioning tool. Devices can be added and system changes can be managed via the panel interface or the commissioning tool. Nano’s commissioning tool has been developed Specifically to improve the set up and commissioning time. The Nano panel has a stylish design that would suit any building.