-
Key Features:; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS -
Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 3 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1x 020-548 - Optional status indicator board kit for 7A PSU 1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H:620mm W:500mm D:122mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer 1 x 020-541-009 - 7A PSU/78AH battery cabinet kit -
Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 2 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1 x 020-474-009 - Extended deep back-box kit space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer -
Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 1 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer -
Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 Loops 1 x 020-579 - 7A PSU 4.5A or 7A User selectable 1 x 020-543 - Dual transmittion path board kit 1 x 020-588 - Dual loop board kit 1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-485-009 - Extension cover blanking kit 1 x 020-481-009 - Extension cover kit -
Certified to EN54 parts 2 and 4 Up to 198 devices per loop (99 sensor and 99 modules) Expandable from 2 to 8 loop capacity Adjustable sensor sensitivity Drift compensation Inter link options Master / Slave Configurable day / night sensitivity adjustment Addressable device LED blink control Automatic or Manual “Loop Learn” options Automatic device “high test” at configured time of day “Walk Test” function by zone for efficient commissioning Configurable “walk test” time limit Auto-program option 600 event history file Duplicate address fault monitoring 2 optional user configurable communication ports Dual pulse rate capability for outputs Pulsing loop powered sounders capability with steady override Non-alarm non-latching addressable device support for lower priority functions Variety of Mounting options Automatic time control functions by day of week for “Control-by-Event” (CBE) Time of day and day of week exclusions for “CBE” Remote reset output capability for peripheral equipment Configurable rapid response from manual call points (less than 3 seconds) 80 Zone capacity per panel Zone sub-division to cells for “CBE” Coincidence detection configurable by zone or cell for “CBE” Fire and fault verification delays configurable by address Pre-defined device type characteristics Output device test activation by address Selective event log display or print by date and time Full configuration edit capability from panel or PC Multiple options for RS232 port protocol -
20 programmable zonal / 25 System LEDs Nittan Evolution protocol Graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware Dedicated USB & RS232 Serial Port for direct PC or modem connection Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding Graphical display configurable for virtually any language Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination Integral P-Bus for system expansion via available option cards Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2 and 4 -
Nexus Repeater Panel 24V Small Enclosure 2500834; Designed for use with Nexus analogue addressable control panels Style to match control panels Available in small cabinet (illustrated) or larger cabinet with zone LEDs and additional printer / equipment space 4 line x 20 character backlit LCD User friendly controls enabled by a keyswitch Unambiguous screen Membrane facia with tactile switches Panel or local mains powered RS485— 2 core data comms -
Features; From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
Features; From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
Features; From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
From 1-8 loops (Apollo XP95 protocol) A clear, backlit display with zonal indication option User-friendly controls Membrane facia with tactile switches Powerful processing ability Windows-based software download package Alarm sensitivity & delay adjustments Message edited by PC or keyboard Fully-networkable with graphics package, Konex network repeaters and other Nexus panels Designed to meet BS5839 part 4 Complies with EMC and LVD Directives -
Designed to EN54: parts 2 and 4 PC based commissioning tools allow complex fire plans to be configured and flexible programming options are available at the panel. The control panel has a simple user interface with LCD screen providing accurate information in an emergency Networks of up to 10 panels can be programmed seamlessly as one system. 2 and 4 loop panels can be connected on the same network allowing flexibility of design In the event of a fire or fault, SenTRI's analogue addressable technology will provide a detailed log of events A built-in printer fitted to the SenTRI FOUR can be used to print out device configurations, loop maps and historic logs. A menu option is available to turn off the printer when a printed record is not required; The SMS SENTRI4-NC is a network card for the SenTRI 4 control panel Model: SENTRI4-NC Shipping Weight: 100gms -
Nano is compatible with Gent’s range of loop powered devices. All devices connect onto the same two core loop, separate sounder wiring circuits are not required. Nano drives advanced detection technology including the full S-Quad range. A building’s fire plan can be configured either at the Nano panel or through the simple PC commissioning tool. Devices can be added and system changes can be managed via the panel interface or the commissioning tool. Nano’s commissioning tool has been developed Specifically to improve the set up and commissioning time. The Nano panel has a stylish design that would suit any building. -
All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed -
All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed -
-
-
Up to 15 annunciators can be connected to each Syncro AS panel Response or Syncro AS fire control panel. Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all Syncro panel controls Simple, two-wire serial connection Small enclosure Removable electronics for easy installation 24V DC or 230V AC power options Low power consumption Multi language options Connection monitored by Syncro fire control panel -
Up to 15 annunciators can be connected to each Syncro AS panel Response or Syncro AS fire control panel. Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all Syncro panel controls Simple, two-wire serial connection Small enclosure Removable electronics for easy installation 24V DC or 230V AC power options Low power consumption Multi language options Connection monitored by Syncro fire control panel -
Up to 15 annunciators can be connected to each Syncro AS panel Response or Syncro AS fire control panel. Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all Syncro panel controls Simple, two-wire serial connection Small enclosure Removable electronics for easy installation 24V DC or 230V AC power options Low power consumption Multi language options Connection monitored by Syncro fire control panel -
16 zonal LED indicators 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Large graphic display Real time clock Certified to EN54-2/4 Sensitivity adjustment and Drift Compensation Stores 500 last events in event log Dial up modem connection available Compact, stylish enclosure Installer friendly, removable equipment chassis Different language and character set variants available Comprehensive day/night mode facility; Variants Available: -
Key Features:; Expandable from 1 to 2 loops Network up to 64 panels 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Up to 512 additional programmable I/O via Syncro I/O modules Powerful, network wide cause and effects Sensitivity adjustment and Drift Compensation Compatible with View repeaters Supports Apollo, Argus Vega and Hochiki protocols Stores 500 last events in event log Installer friendly, removable equipment chassis Different language and character set variants available Approved and certified to EN54-2/ EN54-4 M3 Enclosure - 385 x 520 x 110 -
Key Features:; Expandable from 1 to 2 loops Network up to 64 panels 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Up to 512 additional programmable I/O via Syncro I/O modules Powerful, network wide cause and effects Sensitivity adjustment and Drift Compensation Compatible with View repeaters Supports Apollo, Argus Vega and Hochiki protocols Stores 500 last events in event log Installer friendly, removable equipment chassis Different language and character set variants available Approved and certified to EN54-2/ EN54-4 M3 Enclosure - 385 x 520 x 110 -
One full SLC circuit expandable to two Three programmable relays 5.25A power supply Compatible with eMatrix graphics annunciator Powerful, network wide cause and effects (500 total). Fully user programmable by point or zone Can be networked with additional RS and/or Elite control panels Compatible with eView Annunciator Programmable through a PC connection to the panel Stores 1,000 last events in history log Model ranges include with or without a Dual-Line internal DACT Two programmable NAC circuits with internal synchronization support UL864 listed EN54 Approved versions also available -
Designed to EN54: parts 2 and 4 PC based commissioning tools allow complex fire plans to be configured and flexible programming options are available at the panel. The control panel has a simple user interface with LCD screen providing accurate information in an emergency Networks of up to 10 panels can be programmed seamlessly as one system. 2 and 4 loop panels can be connected on the same network allowing flexibility of design In the event of a fire or fault, SenTRI's analogue addressable technology will provide a detailed log of events A built-in printer fitted to the SenTRI FOUR can be used to print out device configurations, loop maps and historic logs. A menu option is available to turn off the printer when a printed record is not required; Input/Output Card for SenTRI4 Model: SENTRI4-IOC-DOM Shipping Weight: 200gms -
Fully approved to EN54 part 2, 4 & 13 and CE marked under the Construction Products Regulation (CPR) Global compliance Open protocol system 3 year warranty as standard Large graphical LCD user interface Powerful cause & effects programming True, peer to peer networking On board printer option (M enclosure only) 20 zonal LED indicators Programmable push buttons -
Fully expandable system from 1-96 Loops with distributed intelligence for added security Up to 256 devices per loop (TBA) Up to 96 Loop sounders with 32 individually programmable addresses per Loop 96 VULCAN 2 (addressable) ultra-low current sounders or beacons per Loop. Only 64 of these units should be installed per loop when combined sounder beacons are being used. This number includes addressable, shadow, auxiliary and detector-sounder/beacon versions of these units Compatible with major analogue addressable communications protocols 2 Fire output changeover relays and 1 Fault output relay (NC) Open collector outputs for Fire, Fault and pre-alarm remote indication 2 Fully monitored conventional sounder outputs on main panel and each sub panel Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card) 384 Programmable zones 512 Fully programmable sounder and I/O groups Event Log 2000 entries FIFO Backlit LCD display 4 row x 40 characters Programming options: onboard keypad, Remote IR (optional), PS2 Keyboard and GFE Connector Software PC Graphics package ODYSSEY for alarm management and reporting (optional) Multiple Language support (menu selectable) MODBUS (ASCII & RTU) and BMS support -
Fully expandable system from 1-96 Loops with distributed intelligence for added security Up to 256 devices per loop (TBA) Up to 96 Loop sounders with 32 individually programmable addresses per Loop 96 VULCAN 2 (addressable) ultra-low current sounders or beacons per Loop. Only 64 of these units should be installed per loop when combined sounder beacons are being used. This number includes addressable, shadow, auxiliary and detector-sounder/beacon versions of these units Compatible with major analogue addressable communications protocols 2 Fire output changeover relays and 1 Fault output relay (NC) Open collector outputs for Fire, Fault and pre-alarm remote indication 2 Fully monitored conventional sounder outputs on main panel and each sub panel Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card) 384 Programmable zones 512 Fully programmable sounder and I/O groups Event Log 2000 entries FIFO Backlit LCD display 4 row x 40 characters Programming options: onboard keypad, Remote IR (optional), PS2 Keyboard and GFE Connector Software PC Graphics package ODYSSEY for alarm management and reporting (optional) Multiple Language support (menu selectable) MODBUS (ASCII & RTU) and BMS support -
Fully expandable system from 1-96 Loops with distributed intelligence for added security Up to 256 devices per loop (TBA) Up to 96 Loop sounders with 32 individually programmable addresses per Loop 96 VULCAN 2 (addressable) ultra-low current sounders or beacons per Loop. Only 64 of these units should be installed per loop when combined sounder beacons are being used. This number includes addressable, shadow, auxiliary and detector-sounder/beacon versions of these units Compatible with major analogue addressable communications protocols 2 Fire output changeover relays and 1 Fault output relay (NC) Open collector outputs for Fire, Fault and pre-alarm remote indication 2 Fully monitored conventional sounder outputs on main panel and each sub panel Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card) 384 Programmable zones 512 Fully programmable sounder and I/O groups Event Log 2000 entries FIFO Backlit LCD display 4 row x 40 characters Programming options: onboard keypad, Remote IR (optional), PS2 Keyboard and GFE Connector Software PC Graphics package ODYSSEY for alarm management and reporting (optional) Multiple Language support (menu selectable) MODBUS (ASCII & RTU) and BMS support -
Fully expandable system from 1-96 Loops with distributed intelligence for added security Up to 256 devices per loop (TBA) Up to 96 Loop sounders with 32 individually programmable addresses per Loop 96 VULCAN 2 (addressable) ultra-low current sounders or beacons per Loop. Only 64 of these units should be installed per loop when combined sounder beacons are being used. This number includes addressable, shadow, auxiliary and detector-sounder/beacon versions of these units Compatible with major analogue addressable communications protocols 2 Fire output changeover relays and 1 Fault output relay (NC) Open collector outputs for Fire, Fault and pre-alarm remote indication 2 Fully monitored conventional sounder outputs on main panel and each sub panel Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card) 384 Programmable zones 512 Fully programmable sounder and I/O groups Event Log 2000 entries FIFO Backlit LCD display 4 row x 40 characters Programming options: onboard keypad, Remote IR (optional), PS2 Keyboard and GFE Connector Software PC Graphics package ODYSSEY for alarm management and reporting (optional) Multiple Language support (menu selectable) MODBUS (ASCII & RTU) and BMS support