/All Products
  • Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Flameproof Datasheet Apollo - Flameproof Installation Guide
    Details
  • ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide
    Details
  • ATEX & IECEx certified: II 1 G CENELEC/IEC Certified: Ga Ex ia IIC T4 Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +40°C (T4) Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide
    Details
  • Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Datasheet (1) Apollo - Datasheet (2) Apollo - Product Guide Apollo - Installation Guide Apollo - Datasheet (3)
    Details
  • Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Intrinsic Safety - Datasheet Apollo - I.S. Detector - Installation Apollo - I.S. Detector - Product Guide Apollo - Datasheet Apollo - Orbis - Datasheet Apollo - Leaflet
    Details
  • Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Guide Apollo - Datasheet Apollo - Datasheet (2) Apollo - Datasheet (3) Apollo - Leaflet
    Details
  • Environmental Characteristics; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Installation Instructions Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - I.S Detector - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - Datasheet
    Details
  • Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S Detector - Datasheet Apollo - I.S. Detector - Installation Guide Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - Datasheet Apollo - Intrinsic Safety - Datasheet
    Details
  • Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Apollo - I.S Detector - Datasheet Apollo - I.S Detector - Datasheet (2) Apollo - Intrinsic Safety - Datasheet Apollo - Leaflet
    Details
  • Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Guide Apollo - Leaflet Apollo - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - Datasheet (2)
    Details
  • Installation:; Reduces false alarms Sensitive to fast burning, flaming fires Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm; Apollo I.S. Multisensor - Data Sheet Apollo I.S. Multisensor - Installation Manual Apollo I.S. Multisensor - Sales Leaflet About Orbis I.S. Orbis Product Guide
    Details
  • Operation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Orbis ORB-HT-51146-APO - Data Sheet Orbis ORB-HT-51146-APO - Installation Guide About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Sales Leaflet
    Details
  • Key Features:; Reduces false alarms. Sensitive to fast burning, flaming fires. Improved sensitivity to black smoke. Compensation for slow changes in sensitivity. Algorithms for reliability of alarm.; TimeSaver® Base Patented FasTest® enabling functional testing in four seconds DirtAlert® indicates limit of drift compensation Tolerates extreme operating conditions: -40°C to +70 °C False alarm reduction Flashing LED option; Apollo - Multisensor - Product Guide Apollo - Orbis IS - Datasheet (2) Apollo - Orbis - Leaflet Apollo - Intrinsically Safe - Datasheet (3) Apollo - Multi-sensor - Datasheet Apollo - Multisensor - Installation Guide
    Details
  • Operation:; Reduces false alarms. Recommended for early warning of fire in most areas. Improved sensitivity to black smoke. Compensation for slow changes in sensitivity. Algorithms for reliability of alarm.; Optical Smoke Detector - Data Sheet (1) Optical Smoke Detector - Data Sheet (2) Apollo - Intrinsically Safe - Datasheet Apollo - About Orbis IS Apollo - Orbis Smoke Detector
    Details
  • Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet
    Details
  • Installation:; TimeSaver® Base Patented FasTest® enabling functional testing in four seconds DirtAlert® indicates limit of drift compensation Tolerates extreme operating conditions: -40°C to +70 °C False alarm reduction Flashing LED option; Orbis ORB-HT-51148-APO - Installation Guide About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet
    Details
  • Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Apollo ORB-HT-51150-APO - Data Sheet About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet
    Details
  • Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Apollo ORB-HT-51152-APO - Data Sheet About Orbis I.S. About Orbis I.S. Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet
    Details
  • Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Orbis ORB-HT-51154-APO - Data Sheet About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet
    Details
  • Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Orbis ORB-HT-51156-APO - Data Sheet About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet
    Details
  • Operation:; Reduces false alarms Recommended for early warning of fire in most areas Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm; Apollo - Orbis I.S - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - About Orbis I.S. - Datasheet Apollo - Orbis I.S. - Product Guide Apollo - Orbis I.S. - Installation Guide Apollo - Orbis I.S. - Leaflet
    Details
  • Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Series 65 bases Zone-powered; Apollo - Flame Detector Datasheet Apollo - Installation Guide Apollo - Series 65 Leaflet Apollo - Series 65 - Product Guide
    Details
  • Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual
    Details
  • Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual
    Details
  • UV/IR Dual-Sensor High-Speed Response 50m sec Response to Saturated Signal Large Field of View (100° horizontal/vertical) User Programmable Functions Configurable via software from a PC or handheld device Immune to False Alarms (solar blind); Aerospace Industry - Hydroxy fuels, Hydrogen and Hydrazine fuels Aircraft Hangars - landing gear pits, under-wing and over-wing protection Automotive - manufacturing, paint spray booths Chemical Industry - production, storage, transportation Paint - manufacturing facilities Petrochemicals - production, storage, shipping facilities Pharmaceutical Industry Polymers and Glue - manufacturing and curing Power Generation Facilities - pump areas, generator rooms, unmanned stations, gas-fired and coal-fired reactors Printing Industry - solvent handling, presses, drying processes Warehouses - storage facilities for flammable materials; Crowcon 20/20ML - Data Sheet Crowcon 20/20ML - User Manual
    Details
  • Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
    Details
  • Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
    Details
  • Low profile, discreet and unobtrusive Superior performance and reliability Designed for fast, easy installation Series of product approvals; 601F Detector - Data Sheet
    Details
  • Key Features:; High immunity to a false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosions 1.3 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance Data/Event logger -alarms, faults, and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3 - Data Sheet F-Guard IR3 - Operators Manual
    Details
  • High immunity to false alarm Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions Hydrogen flame detection High sensitivity -up to 100 ft.(30m) HD video output with Automatic HD video recording of fire events Data/Event logger -alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-H2-HD - Data Sheet F-Guard IR3-H2-HD - Operators Manual
    Details
  • High immunity to false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire=High immunity to false alarm Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosion 1.2 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance HD video output with Automatic HD video recording of fire events. Data/Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-HD - Data Sheet F-Guard IR3-HD - Operators Manual
    Details
  • Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR - Operators Manual F-Guard UV-IR - Data Sheet
    Details
  • Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; FLS-UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range FLS-UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR-F - Data Sheet F-Guard UV-IR-F - Operators Manual
    Details
  • High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-F-HD - Data Sheet F-Guard UV-IR-F-HD - Operators Manual
    Details
  • High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-HD - Data Sheet F-Guard UV-IR-HD - Operators Manual
    Details
  • Key Features:; Class 1 performance as defined in BS EN54-10:2002 (range up to 25 m) Single IR technology Robust and slim design Low current consumption Easy to install Fits any of the CDX Range of mounting bases Twin LEDs for 360 degree viewing Approved by LPCB & VdS; Hochiki - Flame Detector - Datasheet Hochiki - Flame Detector - Installation Instructions Hochiki - Flame Detector - Leaflet
    Details