  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Multi spectrum design - for long distance detection and high false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities; Spectrex 40/40I - Data Sheet Spectrex 40/40I - User Guide Spectrex 40/40I - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L - Data Sheet Spectrex 40/40L - User Guide Spectrex 40/40L - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40LB - Data Sheet Spectrex 40/40LB - User Guide Spectrex 40/40LB - Accessories
    Details
  • Multi spectrum design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static fuel Cell systems; Spectrex 40/40M - Data Sheet Spectrex 40/40M - User Guide Spectrex 40/40M - Accessories
    Details
  • Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested - EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Spectrex 40/40R - Data Sheet Spectrex 40/40R - User Guide Spectrex 40/40R - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40U - Data Sheet Spectrex 40/40U - User Guide Spectrex 40/40U - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40UB - Data Sheet Spectrex 40/40UB - User Guide Spectrex 40/40UB - Accessories
    Details
  • Multi Spectrum Design - for long distance detection and high false alarm immunity High Speed Response – 50m sec Sensitivity Selection - to ensure no zone crossover detection Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Safety Integrity Level SIL2 (TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance: EN54-10 (VdS) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Spectrex 40/40UFI - Data Sheet Spectrex 40/40UFI - User Guide Spectrex 40/40UFI - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 20m sec to flash fire Solar blind Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year warranty User programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance: EN54-10 (VdS) - FM3260; Explosives & munitions Offshore Oil & Gas Onshore Oil & Gas Petrochemical plants Storage tank farms Aircraft hangars Chemical plants Power generation facilities Pharmaceutical industry Printing industry Warehouses Automotive industry Waste disposal facilities Aerospace industry Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging Areas Refinery Hydrogenation Space Industry Hydroxyl Propellant Static Fuel Cell Systems; Spectrex 40/40UFL - Data Sheet Spectrex 40/40UFL - User Guide Spectrex 40/40UFL - Accessories
    Details
  • Key Features:; High immunity to false sources For applications with visible light present Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002; Churches Coal Handling Fume Cupboards Printing Spray Booths Textiles Waste Handling; Flame Detector - User Manual Flame Detector - EXD Installation Guide Flame Detector - IS Install Guide Flame Detector - Maintenance Guide Flame Detector - Brochure Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • High immunity to false sources For applications with visible light present Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002 IR2 Flame Detector Range; Churches Coal Handling Fume Cupboards Printing Spray Booths Textiles Waste Handling These sensors have been approved by Baseefa (notified body no: 1180) to EN60079-0, EN60079-11 and EN60079-26. The requirements of Directive 94/9/EC, the ATmosphere EXplosives ATEX Directive have also been met. Apparatus Certificate Number: BAS02ATEX1001 System Certificate Number: Baseefa08Y0078 Certified to: ATEX: II 1 G CENELEC/IEC: Ga Ex ia IIC T4; Zones 0, 1, 2; Flame Detector - EXD Installation Guide Flame Detector - User Manual Flame Detector - Brochure Flame Detector - Maintenance Guide Flame Detector - IS Install Guide Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Talentum - 16289 - Datasheet
    Details
  • Fast response time for enclosed and dark areas High Sensitivity to Embers Selectable Output Options; Conventional 2 wire, 4-20mA,Relay Contacts (Fire/Fault, Pre-alarm - Latching or Non-latching) Selectable Response Speed Remote Control Self-Test Low Power Consumption Intrinsically safe (IS) for hazardous areas. Die cast zinc alloy housing Ideal for use on machinery protection applications; Agriculture Bed Fillings Chipboard/MDF Manufacture Dryers Dust Collection/Filters Textiles Paper Production Woodworking; Talentum Spark Detector - Data Sheet Spark detection - Where, when and why? Talentum - One detector for every application
    Details
  • Fast response time for enclosed and dark areas High Sensitivity to Embers Selectable Output Options; Conventional 2 wire, 4-20mA, Relay Contacts (Fire/Fault, Pre-alarm - Latching or Non-latching) Selectable Response Speed Remote Control Self-Test Low Power Consumption Die cast zinc alloy housing Ideal for use on machinery protection applications Continues operation at temperatures up to 55°C; Agriculture Bed Fillings Chipboard/MDF Manufacture Dryers Dust Collection/Filters Textiles Paper Production Woodworking; Talentum Spark Detector - Data Sheet Spark detection - Where, when and why? Talentum - One detector for every application
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Sites Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Aircraft Hangars Coal Handling Printing Petrochemical Offshore/Onshore LNG/LPG Production Biomass Storage and Handling; Talentum IR3 - Data Sheet Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - Wiring Diagram Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can you Talentum detect?
    Details
  • Key Features:; Excellent immunity to false sources Suitable for indoor and outdoor areas Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10: 2002; Atria Coal Handling Pharmaceuticals Printing Spray Booths Nuclear Industry Waste Tips Storage Tanks Tunnels; Flame Detector - Maintenance Guide Flame Detector - Wiring Diagram Flame Detector - IS Install Guide Flame Detector - EXD Installation Guide Flame Detector - User Manual Flame Detector - Data Sheet Flame Detector - Brochure Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist High ambient temperature applications Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Waste Recycling Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production Coal Handling; ATEX & IECEx certified: II 2GD Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP66 A21 Zones 1, 21, 2 and 22; Talentum IR3 Exd - Data Sheet Talentum Exd IR3 - Product Brochure Talentum IR3 Exd - Installation Guide Talentum IR3 Exd - User Manual Talentum IR3 Exd - Maintenance Guide Talentum IR3 Exd - One detector for every application Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Excellent immunity to false sources Increased environmental protection Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Waste Recycling Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production Coal Handling; ATEX & IECEx certified: I I 2GD Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP66 A21 [Zones 1, 21, 2 and 22] SIL 2 rated; Talentum IR3 - Data Sheet Talentum IR3 - Product Brochure Talentum IR3 - Installation Guide Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - One detector for every application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Sites Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Aircraft Hangers Coal Handling Printing Petrochemical Offshore/Onshore LNG/LPG Production Biomass Storage and Handling; Talentum IR3 - Data Sheet Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - Wiring Diagram Talentum One Detector for Every Application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What types of flames can Talentum detect?
    Details
  • Key Features:; Highest immunity to false sources Suitable for indoor and outdoor areas Detects invisible flames from fuels such as hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002; Aircraft hangars Engine rooms Engine test facilities Generators High voltage equipment Nuclear industry Power plants Storage tanks; Flame Detector - Maintenance Guide Flame Detector - User Manual Flame Detector - Wiring Diagram Flame Detector - Installation Guide Flame Detector - Brochure Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Highest immunity to false sources Solar blind Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel loading racks Storage tanks Aircraft hangers Petrochemical onshore/offshore Biomass storage and handling LNG/LPG production; ATEX: II 2GD Ex d IIC T6 [Zones 1, 21, 2 and 22] Worldwide approvals include EN54:10, with VdS and LPCB; Talentum UV / IR2 - User Manual Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - Maintenance Guide Talentum UV / IR - One detector for every application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose What types of flames can Talentum detect?
    Details
  • Highest immunity to false sources Solar blind High ambient temperature applications Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production; ATEX: II 2GD Ex d IIC T6 Zones 1, 21, 2 and 22; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Highest immunity to false sources Increased environmental protection Solar blind Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production; ATEX: II 2GD Ex d IIC T6 Zones 1, 21, 2 and 22 SIL 2 rated.; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - One detector for every application What flame detector should I choose? What type of flames can your Talentum detect? Distance Sensitivity of the Talentum Flame Detectors
    Details
  • Highest immunity to false sources Solar blind High ambient temperature applications Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Generators Compressor Stations High Voltage Equipment Power Plants Fuel Loading Racks Chemical Plants Tunnels Nuclear Power Sites Storage Tanks Engine Rooms Pharmaceutical Production Military Applications Marine Industry Aircraft Hangars Petrochemical Offshore/Onshore LNG/LPG Production; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Wiring Diagram Distance Sensitivity of the Talentum Flame Detector Talentum UV / IR2 - One detector for every application What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Highest immunity to false sources Solar blind Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Generators Compressor Stations High Voltage Equipment Power Plants Fuel Loading Racks Chemical Plants Tunnels uclear Power Sites Storage Tanks Engine Rooms Pharmaceutical Production Military Applications Marine Industry Aircraft Hangars Petrochemical Offshore/Onshore LNG/LPG Production; Worldwide approvals include EN54:10, with VdS and LPCB certification, as well as SIL 2 rated.; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Wiring Diagram Talentum UV / IR2 - One detector for every application Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Key Features:; Solar Blind for false alarm free operation Fast response to flames Detect a 0.1m² fire at a range of 20m Automatic health check feature Discrete ultra-low profile design Fits a standard MZX detector base or functional base Integral alarm LED with 360º angle of view Use T110 infrared test source (With separate adapter); 601F-M Detector - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Key Features:; Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Installer and maintenance friendly; Dual IR detector High specification units for critical applications IP65 Housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non-latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self-test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Ziton - FF742 Datasheet
    Details
  • Key Features:; Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Installer and maintenance friendly; Triple IR detector High specification units for critical applications IP65 Housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non-latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self-test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) EN54-10 & CPD approved; Ziton - FF762 Datasheet
    Details