Pack of 10 transparent hinged covers which have been designed to fit on all Apollo manufactured manual call points. The covers help to provide extra security and protection against accidental operation. -
Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90° field of view Up to 40m coverage -
Key Features: Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90 field of view Up to 40m coverage -
Mimics the characteristics of real flames Wide Spectral Output UV, Visible, Near IR, Mid-IR Tests many flame sensors types UV, UV/IR, UV/IR2, IR3, IR2, IR Portable with Rechargeable NiCd battery pack and charger Selectable Optical Output Type - Constant illumination, Regular flashing sources (range of frequencies), Irregular flickering sources (resembling flames) Selectable optical output intensity with LED bar graph indication Range typically 3 metres and beyond 30 Second timeout on each test Auxiliary 24Vdc supply for testing; Hochiki - Flame Sensor - Datasheet -
The Flame Detector Weather Shield protects the device from inclement conditions. Key Features Protects against water ingress Protects sensor from direct sunlight -
Key Features Protects against water ingress Protects sensor from direct sunlight -
The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Not suitable for Base Mounted Flame Detectors. Key Features: Allows flame detector to be mounted in any orientation. -
Continually corrects itself against building movement Controlled and adjusted from ground level Use XP95 Switch Monitor to interface it to an addressable loop -
Key Features: Continually corrects itself against building movement Controlled and adjusted from ground level Use XP95 Switch Monitor to interface it to an addressable loop -
-
Key Features; ATEX certified IECEx certified; Apollo - Explosion Proof Datasheet -
Key Features ATEX certified IECEx certified -
ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide -
Key Features: ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C -
Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Flameproof Datasheet Apollo - Flameproof Installation Guide -
Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C -
Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Installation Guide -
Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C -
Full icon-based, easy-to-use LCD display on the low level controller for ease of commissioning, testing and maintenance Aesthetically pleasing to suit modern architectural buildings and heritage sites Range 5 to 120 metres Laser assisted alignment combined with easy to use alignment LED's enables installation by one operator Separate Fire/Fault Relays per Detector Selectable sensitivity/threshold levels Automatic Gain control (AGC) for drift compensation -
-
-
Key Features; Resettable operating element Easy access, front reset mechanism Ergonomic reset key Double pole change-over contacts Suitable for semi flush or surface mounting Optional transparent hinged cover -
Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
‘Plug and Play’ terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element -
Key Features:; It is possible to set individual control of the sounder and visual indicator Volume and tone settings can be selected from the control panel Tones can be used for other purposes in addition to warning of fire, ideal for schools Enables soft start option, ideal for hospitals and nursing homes Electronic bell tone -
Brand Information:; 15 pairs of tones It is possible to set individual volume of the sounder from the fire control panel Tones can be used for other purposes in addition to warning of fire, ideal for schools Enables soft start option, ideal for hospitals and nursing homes Unique acoustic and visual indicator self-test -
Key Features:; 4 pre-set message pairs, capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features: 4 pre-set message pairs, capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features:; 4 pre-set message pairs, capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features: 4 pre-set message pairs, capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation -
Key Features:; 15 tone pairs It is possible to set individual control of the sounder and visual indicator Volume and tone settings can be selected from the control panel Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc. Soft start option, ideal for hospitals and nursing homes Group and global control for increased response time -
Key Features: 15 tone pairs It is possible to set individual control of the sounder and visual indicator Volume and tone settings can be selected from the control panel Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc. Soft start option, ideal for hospitals and nursing homes Group and global control for increased response time -
Responds well to slowburning, smouldering fires Well-suited to bedrooms and escape routes Unaffected by wind or atmospheric pressure Five response modes Remote test feature