Installation:; TimeSaver® Base Patented FasTest® enabling functional testing in four seconds DirtAlert® indicates limit of drift compensation Tolerates extreme operating conditions: -40°C to +70 °C False alarm reduction Flashing LED option; Orbis ORB-HT-51148-APO - Installation Guide About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet -
Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Apollo ORB-HT-51150-APO - Data Sheet About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet -
Operation:; Reduces false alarms. Recommended for early warning of fire in most areas. Improved sensitivity to black smoke. Compensation for slow changes in sensitivity. Algorithms for reliability of alarm.; Optical Smoke Detector - Data Sheet (1) Optical Smoke Detector - Data Sheet (2) Apollo - Intrinsically Safe - Datasheet Apollo - About Orbis IS Apollo - Orbis Smoke Detector -
Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet -
Operation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Orbis ORB-HT-51146-APO - Data Sheet Orbis ORB-HT-51146-APO - Installation Guide About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Sales Leaflet -
Key Features:; Reduces false alarms. Sensitive to fast burning, flaming fires. Improved sensitivity to black smoke. Compensation for slow changes in sensitivity. Algorithms for reliability of alarm.; TimeSaver® Base Patented FasTest® enabling functional testing in four seconds DirtAlert® indicates limit of drift compensation Tolerates extreme operating conditions: -40°C to +70 °C False alarm reduction Flashing LED option; Apollo - Multisensor - Product Guide Apollo - Orbis IS - Datasheet (2) Apollo - Orbis - Leaflet Apollo - Intrinsically Safe - Datasheet (3) Apollo - Multi-sensor - Datasheet Apollo - Multisensor - Installation Guide -
Installation:; Reduces false alarms Sensitive to fast burning, flaming fires Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm; Apollo I.S. Multisensor - Data Sheet Apollo I.S. Multisensor - Installation Manual Apollo I.S. Multisensor - Sales Leaflet About Orbis I.S. Orbis Product Guide -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Apollo - I.S Detector - Datasheet Apollo - I.S Detector - Datasheet (2) Apollo - Intrinsic Safety - Datasheet Apollo - Leaflet -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Guide Apollo - Leaflet Apollo - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - Datasheet (2) -
Environmental Characteristics; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Installation Instructions Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - I.S Detector - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - Datasheet -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S Detector - Datasheet Apollo - I.S. Detector - Installation Guide Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - Datasheet Apollo - Intrinsic Safety - Datasheet -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Intrinsic Safety - Datasheet Apollo - I.S. Detector - Installation Apollo - I.S. Detector - Product Guide Apollo - Datasheet Apollo - Orbis - Datasheet Apollo - Leaflet -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Guide Apollo - Datasheet Apollo - Datasheet (2) Apollo - Datasheet (3) Apollo - Leaflet -
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Datasheet (1) Apollo - Datasheet (2) Apollo - Product Guide Apollo - Installation Guide Apollo - Datasheet (3) -
ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide -
ATEX & IECEx certified: II 1 G CENELEC/IEC Certified: Ga Ex ia IIC T4 Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +40°C (T4) Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide -
Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Installation Guide -
Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Flameproof Datasheet Apollo - Flameproof Installation Guide -
Key Features:; Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C Operating temperature -10°C to +55°C; Apollo - Product Datasheet Apollo - Installation Guide Apollo - Datasheet -
Key Features:; Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Conventional IR Installation Guide Apollo - IR Flame Detector - Datasheet Apollo - Conventional IR Flame Detector -Datasheet -
Key Features:; Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Installation Guide Apollo - Flame Detector Datasheet -
Triple IR detector High specification units for critical applications IP66 Housing Flame proof housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) EN54-10 & CPD approved; IR Flame Detector - Data Sheet -
Triple IR detector High specification units for critical applications IP65 Housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) EN54-10 & CPD approved; Intrinsically Safe Flame Detector - Data Sheet -
UV/Dual IR detector High specification units for critical applications IP66 Housing Flame proof housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Remote self test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Infra Red Flame Detector - Data Sheet -
Dual IR detector High specification units for critical applications IP66 Housing Flame proof housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Dual Infra Red Flame Detector - Data Sheet -
Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; High Performance Optical Smoke Detector - Data Sheet -
Features:; Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Discrete ultra low profile design Fits a standard detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors; Infa-Red Flame Detector - Data Sheet -
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; CO & Rate Of Rise Heat Detector - Data Sheet -
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; Rate Of Rise Heat Detector - Data Sheet -
Key Features:; Intrinsically Safe Optical Detector Nittan Y Type Chamber Omniview 360° LED Operational Range (12v-32v) Limited to 28v by External Barrier Use UB-4-IS Base or EV-SPB-IS Base; IS Detector - Instructions IS Detector - Data Sheet -
Ziton ZC6-MCP-IS Intrinsically Safe Surface Mount Call Point 172120; SIRA certificated Modern stylish design Resettable or frangible operating elements Plug in wiring connection Single maintenance tool; IS Call Point - Data Sheet BS5839-2017 Call Point Covers Information Sheet -
Key Features:; Dual Band IR Flame Detector Omniview 360° LED Internal Alarm Current Limiting Resistor Wide Operational Voltage Range (12v-32v); IR Flame Detector - Data Sheet -
BS5839 - Call Point Covers -
Sealed to IP67 Unique ‘Plug & Play’ installation concept Total ‘Flex-Ability’ in the choice of operating element Anti-Tamper facility Enhanced aesthetics and compact design Fully approved to the latest standards CPD Approval; I.S. Call Point - Data Sheet -
Morley Call Point - Data Sheet BS5839-2017 Call Point Covers Information Sheet -
Key Features:; IS Call Point - Instructions IS Call Point - Data Sheet -
Key Features:; Sealed to IP67 Unique "Plug & Play" installation concept Total "Flex-Ability" in the choice of operating element Anti-Tamper facility Enhanced aesthetics and compact design Fully approved to the latest standards CPD Approval; Hochiki - CCP-W-IS - Datasheet -
Key Features:; IS Call Point - Instructions IS Call Point - Data Sheet -
Key Features:; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The push button is user resettable via the use of the special key supplied with the unit. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet -
Key Features:; The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The product is user resettable by rotating the push button. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The push button is user resettable via the use of the special key supplied with the unit. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The product is user resettable by rotating the push button. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExd Call Point - Installation Sheet EExD Call Point - Data Sheet -
Key Features:; IS Call Point - Instructions IS Call Point - Data Sheet -
Key Features:; The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet