-
Ziton DMN700R470 470 ohm Flush Call Point and Free Contact with Glass; Enhanced aesthetics Easy to install (plug and play) Surface mount options Protection hinged cover with Anti-Tamper facility Backward compatible Key test facility May be used with glass or resettable element Easy to replace glass High quality micro switch Fully approved to the latest standards -
-
-
Ziton Double-Pole Green Surface Call Point with Glass – DMN702G; Enhanced aesthetics Easy to install (plug and play) Surface mount options Protection hinged cover with Anti-Tamper facility Backward compatible Key test facility May be used with glass or resettable element Easy to replace glass High quality micro switch -
Dual IR detector High specification units for critical applications IP65 Housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non-latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self-test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10 -
Installer and maintenance friendly; Dual IR detector High specification units for critical applications IP65 Housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non-latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self-test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Ziton - FF742 Datasheet -
Key Features:; Ready to install Easy to install Fits into standard detector base -
Key Features:; Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet -
Enhanced aesthetics Easy to install (plug and play) Protection hinged cover with Anti-Tamper facility Backward compatible Key test facility May be used with glass or resettable element Easy to replace glass High quality micro switch -
Features; ATEX approved EEx ia IIC T4 rating IP65 High efficiency LED's; Intrinsically Safe LED Beacon - Data Sheet -
Ziton FA375 Hazardous Area Xenon Beacon; ATEX approved EExd IIC T6 rating IP67 5J Xenon Lens guard; Hazardous Area Xenon Beacon - Data Sheet -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Shallow mounting base Wiring directly to base Flash rate selectable -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Shallow mounting base Wiring directly to base Flash rate selectable -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Deep mounting base Wiring directly to base Flash rate selectable IP65 Ingress protection rating -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Deep mounting base Wiring directly to base Flash rate selectable IP65 Ingress protection rating -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Deep mounting base Wiring directly to base Flash rate selectable IP65 Ingress protection rating -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Shallow mounting base Wiring directly to base Flash rate selectable -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Shallow mounting base Wiring directly to base Flash rate selectable -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Deep mounting base Wiring directly to base Flash rate selectable IP65 Ingress protection -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Deep mounting base Wiring directly to base Flash rate selectable IP65 Ingress protection -
Key Features:; Automatic synchronisation Anti-Tamper locking mechanism Deep mounting base Wiring directly to base Flash rate selectable IP65 Ingress protection -
Ultra slim heating pad Designed to prevent the build-up of condensation For use in temperature controlled storage areas and cold environments Optical Beam Smoke Detector Heaters (FD-CH1, FD-CH2, FD-CH3) also available -
Easy adjustable 0° to 45° range -
Easy adjustable 0° to 45° range -
Easy adjustable 0° to 45° range -
Easy adjustable 0° to 90° range -
Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller Supply voltage: 12-36VDC Current: Controller 14mA, per transmitter head 8mA Fire and Fault relays per detector head - rated 2A 30VDC Detector head dimensions per transmitter and receiver unit (mm): 74w x 74h x 161d Controller dimensions (mm): 203w x 124h x 73d -
Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller -
Used with FDD710 duct detector Extra-long for large ducts Unique one-pipe sampling system Easy installation -
Single installation and maintenance point Fully addressable 100 metre detection range Unique simple alignment Selectable alarm thresholds Latching or auto reset fire output Automatic contamination compensation -
Single installation and maintenance point Fully addressable 50 metre detection range Unique simple alignment Selectable alarm thresholds Latching or auto reset fire output Automatic contamination compensation -
Key Features:; Stainless steel Fixed non-swivel low profile anchor plate Used for the FE500 series of door magnets; Door Holder Plate - Data Sheet -
Key Features:; Swivel base allows universal installation Used with FE500 series of magnets Rugged, strong body; Door Holder Plate - Data Sheet -
Key Features:; Explosion proof surface mount body 588N holding force Low power - 3 W Reverse polarity protection ATEX approval - EX IIG Eex me II T6; Explosion Door Magnet - Data Sheet -
Dual IR detector High specification units for critical applications IP66 Housing Flame proof housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Dual Infra Red Flame Detector - Data Sheet -
UV/Dual IR detector High specification units for critical applications IP66 Housing Flame proof housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Remote self test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Infra Red Flame Detector - Data Sheet