Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions -
EN54 Approved from LPCB Marine approved Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Integrated alarm LED Remote LED connection Wiring polarity independent; Applications used in:; kitchens, locker rooms canteens loading bays etc. -
Key Features:; Approved by all major classification societies for use on vessels EN54 Approved from LPCB Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Wiring polarity independent -
-
Key Features:; Red LED indicator 'Plug and Play' terminal connections for fast wiring Resettable element -
Complies with EN54-11 Push-fit terminals can accommodate up to a 2.5mm2 solid conductor Unique ‘Plug & Play’ installation concept Re-settable operating element option Resistive and clean contact connections Semi-flush or surface mounting Backward compatibility Approved by GL -
Key Features:; Approved to EN54-11:2001 Terminals can accommodate up to a 2.5 mm solid conductor Ingress Protection rated to IP67 Approved to MED by GL GL Type Approval Approved by LPCB -
Key Features:; Integral LED for easy identification of operation Call points are identified separately at the controller even for conventional panels For ease of installation various configurations are available Accidental operation can be prevented by optional covers -
Key Features:; Integral LED for easy identification of operation Call points are identified separately at the controller even for conventional panels For ease of installation various configurations are available Accidental operation can be prevented by optional covers -
Key Features:; Red LED indicator 'Plug and Play' terminal connections for fast wiring Resettable element -
Key Features:; Red LED indicator 'Plug and Play' terminal connections for fast wiring Resettable element -
152mm (6”) Gong High sound output Low current consumption Locking facility Simple installation No backbox required for surface wiring Weatherproof (WP) kit available MED certification -
152mm (6”) Gong High sound output Low current consumption Locking facility Simple installation No backbox required for surface wiring Weatherproof (WP) kit available MED certification -
152mm (6”) Gong High sound output Low current consumption Locking facility Simple installation No backbox required for surface wiring Weatherproof (WP) kit available MED certification -
-
Detector locking mechanism One way fit Easy to wire Contains an earth connector Contains no electrical parts Terminal for remote indicator -
Key Features:; Integral remote indicator output Low Profile, only 8 mm Rugged design Electronics free Quick connections via square cable clamps Accepts 2.5 mm cables Bayonet slot, low insertion force for detectors Approved to MED by GL GL Type approval -
4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to ivory detector range Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-1) -
4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to white detector range Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-1) -
Key Features:; 4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to both ivory and white detector ranges Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-2) -
Key Features:; Grouped terminals to make wiring easy Multiple fixing centres LED alignment mark Cable stripping guide Continuity link for voltage testing of zone wiring prior to commissioning Detector locking mechanism; Approved for use in marine environments Modern, low-profile design TimeSaver® Base for fast installation Transient rejection for false alarm reduction High humidity tolerance at up to 98% RH Wide operating temperature -40°C to +70°C -
4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to both ivory and white detector ranges Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-2) -
Grouped terminals to make wiring easy Multiple fixing centres LED alignment mark Cable stripping guide Continuity link for voltage testing of zone wiring prior to commissioning Detector locking mechanism -
Key Features:; Loop Powered and compatible with XP95, Discovery and CoreProtocol* Incorporates a bi directional short-circuit isolator Automatic drift compensation Automatic reset Ground level Controller Automatic alignment compensation for building movement Laser assisted alignment for quick installation Allows for 2 detector heads per controller Up to 100m range Pre-alarm threshold EN 54-12 and EN 54-17 certified