-
IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers -
IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers -
Detection as precise as 0.0015%/m obscuration Integral Ethernet interface enables remote monitoring and e-mail status updates Patented particle separator and field-replaceable filter remove contaminants from the system Five alarm levels & two sensitivity modes Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement Protects up to 2,000 square metres Advanced detection algorithms reject common nuisance conditions PipeIQâ„¢ software provides intuitive system layout, configuration, and monitoring all in one package Fault indictors covering a broad spectrum of events Unique air flow pendulum graph verifies pipe network functionality Particulate graph displays subtle environmental changes for early problem indications -
Approved for use in Class A, B and C, according to EN54-20 Provides Very Early Warning Fire Detection, as precise as 0.00095%/m obscuration Three alarm levels and three sensitivity modes provide application flexibility User configurable 3-speed fan, allowing for maximum coverage area or minimizing on current consumption Patented particle separator removes large, non-fire particulate, ensuring chamber health and extending the life of the field-replaceable filter Easy configuration via USB interface, no external power needed Configurable air flow fault thresholds and verification period Convenient wiring compartment -
Approved to EN 54-20 in Class A, B and C Provides Very Early Warning Fire Detection, as precise as 0,00095 %/m Five alarm levels and three sensitivity modes provide application flexibility User configurable 3-speed fan, allowing for maximum coverage area or minimizing on current consumption Ultrasonic flow sensing for each pipe inlet and chamber airflow monitoring for precise system health information Dual source optical detection chamber with enhanced algorithms provide high sensitivity with greater immunity to nuisance conditions Easy configuration via USB interface, no external power needed Onboard Ethernet interface enables remote monitoring, configuration, web server and e-mail notifications -
Key Features:; Robust mild steel construction, powder coated to give an attractive finish Ideal for the storage of log books, O&M guides, manuals, ‘as fitted’ drawings and certificates 6 convenient hooks for storage of keys Lockable enclosure including indent for optional customer branding -
Key Features:; Site selectable single or twin 24 V dc output 24 hour or 72 hour standby capability Fully monitored to EN54-4 Local LEDs for fast fault-finding Top or rear cable entry Space for up to 2 x 17Ah batteries -
Key Features:; Site selectable single or twin 24 V dc output 24 hour or 72 hour standby capability Fully monitored to EN54-4 Local LEDs for fast fault-finding Top or rear cable entry Space for up to 2 x 17Ah batteries -
-
-
-
-
-
-
Two versions available: Standard and Harsh Environments Clear and easily accessible visual colour-coded guide to sample hole location and sampling hole size; even in the largest format applications Installation-ready design (with no part assembly or tools required); each CLIP simply clicks into place for a firm, non-slip position Greatly simplifies sample hole drilling; a single 12mm drill can be used to create all holes (simply fit the relevant CLIP to limit the hole size after initial hole drilling) Harsh Environment CLIPS feature a flexi-lip that can adapt to any changes caused by environmental fluctuations including freezing; any dust, ice or fibre will detach and break apart easily, ensuring even air flow sampling in all conditions Reduces dust loading effects through inclusion of a chamfered hole Permits faster, more efficient commissioning and installation, as well as ongoing maintenance -
Two versions available: Standard and Harsh Environments Clear and easily accessible visual colour-coded guide to sample hole location and sampling hole size; even in the largest format applications Installation-ready design (with no part assembly or tools required); each CLIP simply clicks into place for a firm, non-slip position Greatly simplifies sample hole drilling; a single 12mm drill can be used to create all holes (simply fit the relevant CLIP to limit the hole size after initial hole drilling) Harsh Environment CLIPS feature a flexi-lip that can adapt to any changes caused by environmental fluctuations including freezing; any dust, ice or fibre will detach and break apart easily, ensuring even air flow sampling in all conditions Reduces dust loading effects through inclusion of a chamfered hole Permits faster, more efficient commissioning and installation, as well as ongoing maintenance -
Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4 -
Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4 -
-
Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Automatic synchronisation of sounder Low current draw enables more devices on loop Adjustable volume control (on device or from panel) Intense strobe output Deep and high IP base options Pure White or Ivory body colours Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets (on device or from panel) -
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
Combined transmitter and receiver unit Range 10-100 metres using the long range reflector kit 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-Red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom ±10° horizontal and vertical beam alignment Automatic drift compensation Loop powered Complies to EN54-12 Extended Warranty