UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L - Data Sheet Spectrex 40/40L - User Guide Spectrex 40/40L - Accessories -
Multi spectrum design - for long distance detection and high false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities; Spectrex 40/40I - Data Sheet Spectrex 40/40I - User Guide Spectrex 40/40I - Accessories -
Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook -
Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps; Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook -
Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook -
Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide -
Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide -
Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1 sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two 25 mm conduit entries or two ¾” NPT Low power consumption High RFI and EMI immunity FM hazardous area approved Ex d ATEX approved CU-TR approved INMETRO approved Meets SIL 2 requirements Certified to EN54-10:2002 (option) FM 3260 performance; Refineries and oil production facilities Off-Shore platforms Turbine/Compressor enclosures Acetylene processing and storage Oil and Gas pipelines and pumping stations LNG/LPG loading and unloading facilities Natural Gas and CNG plants Ethanol, Methanol, and IPA production and storage Crude oil and gasoline storage and tank farms Aircraft hangars Hydrogen plants and storage Paint and solvent storage Chemical production, storage, and loading facilities Power plants Silane gas storage; Morley FS20X-211-24-6 - Data Sheet Morley FS20X-211-24-6 - Installation Manual -
Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° field of view Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two M25 conduit entries Low power consumption; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide -
Removable, High Performance chamber Twin fire LEDs allow 360 degree viewing Supported by a range of barriers Remote indicator output ATEX Classification to: II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in ivory Approved by LPCB & VdS; Hochiki - Smoke Detector - Installation Instructions Hochiki - Smoke Detector - Datasheet -
Removable, High Performance chamber Twin fire LEDs allow 360 degree viewing Supported by a range of barriers Remote indicator output ATEX Classification to: II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in white Approved by LPCB & VdS; Hochiki - Smoke Detector - Installation Instructions Hochiki - Smoke Detector - Datasheet Hochiki - Smoke Detector - Datasheet (2) -
Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours, dust and mist Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - Datasheet Hochiki - User Manual Hochiki - Certificate of Conformity -
Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours dust and mist ATEX certification to: EEx ia IIC T4 (135 C) (zones 0, 1 and 2) Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - IS Detector - Brochure Hochiki - IS Detector - Installation Instructions Hochiki - IS Detector - Datasheet -
Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours, dust and mist ATEX certified to EEx d IIC T6 (85 C) (zones 1, 21, 2 and 22) Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - Flame Detector - Datasheet Hochiki - Flame Detector - Leaflet Hochiki - Flame Detector - Installation Instructions -
Key Features:; Twin fire LEDs allow 360 degree viewing Electronics free mounting base Remote indicator output ATEX Classification to II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in ivory Approved by LPCB and GL SIL2 Approved variant available; Hochiki - Heat Detector - Datasheet Hochiki - Heat Detector - Installation Guide -
Key Features:; Twin fire LEDs allow 360 degree viewing Electronics free mounting base Remote indicator output ATEX Classification to II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in white Approved by LPCB and GL SIL2 Approved variant available; Hochiki - IS Technology Guide Hochiki - Rate of Rise Detector - Specification Hochiki - Smoke Detector - Installation Guide Hochiki - Heat Detector - Datasheet Hochiki - IS Technology - Application Notes -
Key Features:; Class 1 performance as defined in BS EN54-10:2002 (range up to 25 m) Single IR technology Robust and slim design Low current consumption Easy to install Fits any of the CDX Range of mounting bases Twin LEDs for 360 degree viewing Approved by LPCB & VdS; Hochiki - Flame Detector - Datasheet Hochiki - Flame Detector - Installation Instructions Hochiki - Flame Detector - Leaflet -
High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-HD - Data Sheet F-Guard UV-IR-HD - Operators Manual -
High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-F-HD - Data Sheet F-Guard UV-IR-F-HD - Operators Manual -
Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; FLS-UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range FLS-UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR-F - Data Sheet F-Guard UV-IR-F - Operators Manual -
Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR - Operators Manual F-Guard UV-IR - Data Sheet -
High immunity to false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire=High immunity to false alarm Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosion 1.2 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance HD video output with Automatic HD video recording of fire events. Data/Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-HD - Data Sheet F-Guard IR3-HD - Operators Manual -
High immunity to false alarm Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions Hydrogen flame detection High sensitivity -up to 100 ft.(30m) HD video output with Automatic HD video recording of fire events Data/Event logger -alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-H2-HD - Data Sheet F-Guard IR3-H2-HD - Operators Manual -
Key Features:; High immunity to a false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosions 1.3 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance Data/Event logger -alarms, faults, and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3 - Data Sheet F-Guard IR3 - Operators Manual -
Low profile, discreet and unobtrusive Superior performance and reliability Designed for fast, easy installation Series of product approvals; 601F Detector - Data Sheet -
Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual -
Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual -
UV/IR Dual-Sensor High-Speed Response 50m sec Response to Saturated Signal Large Field of View (100° horizontal/vertical) User Programmable Functions Configurable via software from a PC or handheld device Immune to False Alarms (solar blind); Aerospace Industry - Hydroxy fuels, Hydrogen and Hydrazine fuels Aircraft Hangars - landing gear pits, under-wing and over-wing protection Automotive - manufacturing, paint spray booths Chemical Industry - production, storage, transportation Paint - manufacturing facilities Petrochemicals - production, storage, shipping facilities Pharmaceutical Industry Polymers and Glue - manufacturing and curing Power Generation Facilities - pump areas, generator rooms, unmanned stations, gas-fired and coal-fired reactors Printing Industry - solvent handling, presses, drying processes Warehouses - storage facilities for flammable materials; Crowcon 20/20ML - Data Sheet Crowcon 20/20ML - User Manual -
Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual -
Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual -
Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Series 65 bases Zone-powered; Apollo - Flame Detector Datasheet Apollo - Installation Guide Apollo - Series 65 Leaflet Apollo - Series 65 - Product Guide -
Operation:; Reduces false alarms Recommended for early warning of fire in most areas Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm; Apollo - Orbis I.S - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - About Orbis I.S. - Datasheet Apollo - Orbis I.S. - Product Guide Apollo - Orbis I.S. - Installation Guide Apollo - Orbis I.S. - Leaflet -
Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Orbis ORB-HT-51156-APO - Data Sheet About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet -
Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Orbis ORB-HT-51154-APO - Data Sheet About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet -
Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Apollo ORB-HT-51152-APO - Data Sheet About Orbis I.S. About Orbis I.S. Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet -
Installation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Apollo ORB-HT-51150-APO - Data Sheet About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Installation Guide Orbis I.S. Sales Leaflet