Very low power consumption means more sounders and strobes per circuit The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power 32 sounder tones are available Voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard All sound and strobe signals are synchronised to better than +/-30mS over 20 minutes Sounders and strobes are compatible with 12V and 24V systems A third wired option allows the selection of 2 alternative sounds (ideal for class change applications) Products incorporate innovative design features for which multiple patents have been granted -
Building on IGD's existing Addressable Gas Detectors, the 750 Series add 2-Wire addressable technology. Using IGD?s Sentinel+ 2-Wire protocol the 750 Series communicate over the detector power cables. This reduces cabling and terminations whilst improving reliability. Sentinel+ protocol continuously monitors data between connected detectors and the system controller ensuring maximum system availability. With only two wires for power and communication existing systems can be easily upgraded using existing cables with the option to easily add more detectors where required. -
5083101 - Beacon sounder Amber/Red. 24V DC mutable tone adjust facility. 1Hz Flash Rate. 5083150 - Beacon Sounder Red. 24V DC mutable tone adjust facility. 1Hz Flash Rate. 5083160 - Beacon Sounder Blue. 24V DC Not mutable tone adjust facility. 1Hz Flash Rate. -
-
Features; Designed to meet the requirements of EN54-11 Provides high reliability and error detection Short circuit isolators in each device Large capacity, up to 240 devices per loop Addressable via VPU100 programmer Auto addressing capability (Control panel feature) OEM password protection High power availability from loop (>98%), Digital checking of double address Line quality information Bicolour (red green) LED driven by the control panel -
Designed to EN54: parts 2 and 4 PC based commissioning tools allow complex fire plans to be configured and flexible programming options are available at the panel. The control panel has a simple user interface with LCD screen providing accurate information in an emergency Networks of up to 10 panels can be programmed seamlessly as one system. 2 and 4 loop panels can be connected on the same network allowing flexibility of design In the event of a fire or fault, SenTRI's analogue addressable technology will provide a detailed log of events A built-in printer fitted to the SenTRI FOUR can be used to print out device configurations, loop maps and historic logs. A menu option is available to turn off the printer when a printed record is not required; Input/Output Card for SenTRI4 Model: SENTRI4-IOC-DOM Shipping Weight: 200gms -
Suited for industrial settings with the potential of larger burns while still handling your more minor burn needs. This Burn Kit offers different combinations of Burn Dressings, Fire Blankets and Burn Jel for large or minor burns. Item IWK-HA Sterile Burn Dressings: One 12" x 16" One 8" x 18" Two 4" x 4" Two 2" x 6" One 4" x 16" Dispenser Box of (25) Single-Dose Burn Jel Packets One Elastic Bandage One Instruction Card High-Impact Carry Case Case Pack: 5 kits Case Weight: 23.3 lbs. Case Size: 16in. x 12in. x 8in. (40.6 x 30.5 x 20.3 cm) Unit Dimensions: 9.94in. x 3in. x 7.25 in. Unit Weight: 3.4 lbs. -
Benefits:; High security 868Mhz 7-channel encrypted communications protocol proven in a large installed base of fire and security systems. Units powered by low cost, readily available 3V lithium batteries. 5 year primary battery life with an additional 2 months from the secondary back up cell. Patented multi-directional antennae virtually eliminates data corruption and signal fade. Designed to meet EN54 part 25 and BS5839. All system elements are very competitively priced. Easy installation and comissioning. Wireless hardware costs are comparable with the equivalent installed hardware devices. Lifetime cost of ownership is low. No hazardous substances used in the units or batteries, so no end of life special disposal costs. Up to 32 devices per translator module and up to 7 expander modules to give enhanced range and coverage. Compatible with leading fire panel manufacturers' addressable protocols. Wireless multi-criteria, optical and thermal detectors. Wireless call point. Wireless sounders and beacons. Wireless input and output modules. Attractively styled detectors are only 65mm deep. Unique decorline optional custom finish. -
High security 868Mhz 7-channel encrypted communications protocol proven in a large installed base of fire and security systems. Units powered by low cost, readily available 3V lithium batteries. 5 year primary battery life with an additional 2 months from the secondary back up cell. Patented multi-directional antennae virtually eliminates data corruption and signal fade. Designed to meet EN54 part 25 and BS5839. All system elements are very competitively priced. Easy installation and comissioning. Wireless hardware costs are comparable with the equivalent installed hardware devices. Lifetime cost of ownership is low. No hazardous substances used in the units or batteries, so no end of life special disposal costs. Up to 32 devices per translator module and up to 7 expander modules to give enhanced range and coverage. Compatible with leading fire panel manufacturers' addressable protocols. Wireless multi-criteria, optical and thermal detectors. Wireless call point. Wireless sounders and beacons. Wireless input and output modules. Attractively styled detectors are only 65mm deep. Unique decorline optional custom finish. -
3rd party certified Colour options available 5-year product warranty Central LED for 360° visibility Low profile design Programmable flashing LED function -
-
High security 868Mhz 7-channel encrypted communications protocol proven in a large installed base of fire and security systems. Units powered by low cost, readily available 3V lithium batteries. 5 year primary battery life with an additional 2 months from the secondary back up cell. Patented multi-directional antennae virtually eliminates data corruption and signal fade. Designed to meet EN54 part 25 and BS5839. All system elements are very competitively priced. Easy installation and comissioning. Wireless hardware costs are comparable with the equivalent installed hardware devices. Lifetime cost of ownership is low. No hazardous substances used in the units or batteries, so no end of life special disposal costs. Up to 32 devices per translator module and up to 7 expander modules to give enhanced range and coverage. Compatible with leading fire panel manufacturers' addressable protocols. Wireless multi-criteria, optical and thermal detectors. Wireless call point. Wireless sounders and beacons. Wireless input and output modules. Attractively styled detectors are only 65mm deep. Unique decorline optional custom finish.