/All Products
  • Clear back-lit 40-character 8-line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self-Auto Learn capabilities Day Night sensitivity settings Versatile multi-processor architecture Event log and printer options Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Complies to EN54-2 and 4
    Details
  • Clear back-lit 40-character 8-line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self-Auto Learn capabilities Day Night sensitivity settings Versatile multi-processor architecture Event log and printer options Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Complies to EN54-2 and 4
    Details
  • Clear back-lit 40-character 8-line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self-Auto Learn capabilities Day Night sensitivity settings Versatile multi-processor architecture Event log and printer options Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Complies to EN54-2 and 4
    Details
  • 1 loop with up to 512 zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dail with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
    Details
  • Ideal for monitoring up to 126 sprinkler flow switches. One switch monitoring unit required per monitored flow switch. Utilises the same technology as C-TEC's popular XFP addressable fire panel. Up to 16 sprinkler zone indicators available (assignable via the panel’s PC programming tools). Attractive flush or surface mountable plastic enclosure. Combined keypad or keyswitch entry.
    Details
  • Key Features:; Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB). Compatibility with Apollo's XP95/Discovery protocol. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependency/coincidence functions. A day/night (building occupied/unoccupied) function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop. An integral EN54-4/A2 switch mode power supply. Adjustable contamination levels. Earth fault monitoring. Combined keypad / keyswitch entry to Access Levels 2 and 3. 999 event monitoring. An intuitive Windows based upload-download PC program. Optional flush-mounting bezel and glazed stainless steel enclosure also available. Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
    Details
  • Key Features:; Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB). Compatibility with Apollo's XP95/Discovery protocol. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependency/coincidence functions. A day/night (building occupied/unoccupied) function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop. An integral EN54-4/A2 switch mode power supply. Adjustable contamination levels. Earth fault monitoring. Combined keypad / keyswitch entry to Access Levels 2 and 3. 999 event monitoring. An intuitive Windows based upload-download PC program. Optional flush-mounting bezel and glazed stainless steel enclosure also available. Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
    Details
  • Key Features:; Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB). Compatibility with Apollo's XP95/Discovery protocol. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependency/coincidence functions. A day/night (building occupied/unoccupied) function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop. An integral EN54-4/A2 switch mode power supply. Adjustable contamination levels. Earth fault monitoring. Combined keypad / keyswitch entry to Access Levels 2 and 3. 999 event monitoring. An intuitive Windows based upload-download PC program. Optional flush-mounting bezel and glazed stainless steel enclosure also available. Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
    Details
  • Key Features:; Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB). Compatibility with Apollo's XP95/Discovery protocol. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependency/coincidence functions. A day/night (building occupied/unoccupied) function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop. An integral EN54-4/A2 switch mode power supply. Adjustable contamination levels. Earth fault monitoring. Combined keypad / keyswitch entry to Access Levels 2 and 3. 999 event monitoring. An intuitive Windows based upload-download PC program. Optional flush-mounting bezel and glazed stainless steel enclosure also available. Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
    Details
  • Configurable as a 1 or 2 loop panel Up to 200 addresses per loop Full network capability up to 126 panels Network compatible with CF1000VDS and CF3000 ranges Soft addressing Menu-driven graphic screen Multi-language selection capability Integral battery and power supply Flexible cause and effect programming; Easy to operate end user controls Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper developed protocol
    Details
  • Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Key Features:; Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Available in 1, 2 and 4 loop versions Up to 200 addresses per loop Full network capability up to 126 panels Event History Buffer (9,999 events) with Date/Time stamp Soft addressing Large versatile touch screen user interface Multi-language selection capability Integral printer (optional) Integral battery and power supply Flexible cause and effect programming; Simple to operate end user touch-screen interface Flexible distributed network capability Full range of compatible accessories Easy to design system cause and effect using site installer software Full system integrity with Cooper managed protocol
    Details
  • Touchscreen Display 2 or 4 Class A Style 7 SLC loops Event History Buffer (9,999 events) with Date/Time stamp 4 Notification appliance circuits (NAC's) outputs 3 programmable general purpose relays Dedicated alarm and trouble relays Short circuit isolators incorporated into each loop Up to 200 addresses per loop Fully monitored network cable up to 126 panels Optional integral printer Alarm Verification PAS (Positive Alarm Sequenc Pre-Signal per Point (NFPA 70, 72 compliant) Remote Alarm, NAC silenced, Alarm Reset, Trouble, Supervisory and drill via addressable module; Supports a comprehensive range of soft addressing modules and devices for greater flexibility in design Menu driven graphical user interface for ease of operation Reduced commissioning time through soft addressing and auto learn functions Programming and trouble-shooting time minimised by using a range of features such as auto config, walk test, system details, analogue values, etc
    Details
  • Touchscreen Display 2 or 4 Class A Style 7 SLC loops Event History Buffer (9,999 events) with Date/Time stamp 4 Notification appliance circuits (NAC's) outputs 3 programmable general purpose relays Dedicated alarm and trouble relays Short circuit isolators incorporated into each loop Up to 200 addresses per loop Fully monitored network cable up to 126 panels Optional integral printer Alarm Verification PAS (Positive Alarm Sequenc Pre-Signal per Point (NFPA 70, 72 compliant) Remote Alarm, NAC silenced, Alarm Reset, Trouble, Supervisory and drill via addressable module; Supports a comprehensive range of soft addressing modules and devices for greater flexibility in design Menu driven graphical user interface for ease of operation Reduced commissioning time through soft addressing and auto learn functions Programming and trouble-shooting time minimised by using a range of features such as auto config, walk test, system details, analogue values, etc
    Details
  • Large versatile touchscreen user interface Multi-language selection capability Full network capability up to 126 panels Programmable as an active or passive repeater Plug and play (all system information is uploaded through the network) Integral battery and power supply; Aesthetical, compact panel Simple to operate end user touch-screen interface Requires no programming (plug and play) Full system visibility and control
    Details
  • 1, 2 and 4 loop versions Spur tolerant soft addressing Full network capability Optional integral printer Integral battery and power supply 200 addresses per loop Charger with temperature compensation built in Checks battery capacity; Simple end user interface Range of compatible ancillaries Easy to design system System Integrity Battery life can be extended
    Details
  • Zonal LED indicators Stores 500 last events in event log Powerful and versatile cause & effect programming Programmable inputs Programmable relays Programmable sounder circuits Up to 126 wireless FireCell devices per loop Integrated power supply Third party EN certified
    Details
  • Key Features:; Zonal LED indicators Stores 500 last events in event log Powerful and versatile cause & effect programming Programmable inputs Programmable relays Programmable sounder circuits Up to 126 wireless FireCell devices per loop Integrated power supply Third party EN certified
    Details
  • Duonet 1-2 Loop, Quadnet 1-4 Loop and repeater panel. Large display to aid event identification. Soft addressing. Distributed intelligence - network up to 8 panels or repeaters. Fast short circuit isolator in every device. 15 combinations of smoke and heat detection modes. Loop length up to 2km long. Loop capacity up to 200 devices with built in sounder. Digital communication with high power transfer. Multi stage alarms - pre alarm feature. Very low current consumption. 7 sound patterns - and 3 volume settings. Auxiliary digital inputs and outputs are available at any ASD detector. Automatic continuous self-calibration. ASD detectors are monitored for all failures of sensor chamber - warning is indicated. Advanced commissioning software.
    Details
  • Up to 250 addresses available on panel 640 Character Display Permanently displays system status Displays temperature, CO level and smoke level at point in alarm Viewing 3000 event log Manual and Automatic walk test and reporting functions Automatic battery test Detector service functions Front panel controls enabling text and configuration changes
    Details