/All Products
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 2 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1 x 020-474-009 - Extended deep back-box kit space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 3 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1x 020-548 - Optional status indicator board kit for 7A PSU 1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H:620mm W:500mm D:122mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer 1 x 020-541-009 - 7A PSU/78AH battery cabinet kit
    Details
  • Key Features:; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • 240 x 60 Graphic LCD H165mm x W254mm x D50mm Requires external power source
    Details
  • Extended capacity:; The Pearl supports up to 636 loop devices (159 detectors plus 159 modules per loop) Longer loops, but fewer of them, will give the opportunity to save on installation time, cost and wiring Highly resilient Opal system, able to pinpoint a loop fault whilst maintaining full system operation Powerful networking capability - Up to 16 Pearl panels, controlling over 10,000 devices, can be networked via the superfast ID2net; prioritising a fire signal to communicate across a network in under three seconds; Intuitive on-site management - backlit buttons for fast, error free situation management, and large display giving complete information at a glance Simpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector status Text programming via MS Excel spread sheet User permissions set per individual password; Unique first fix bracket with adaptations for 19” rack or flush mounting. Fast system set up and commissioning via the panel, loop “Autolearn” and advanced PC tools suite Comprehensive “Cause & Effect” programming capability Panel sounder and beacon synchronisation System extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cabling Separate text change without risk to “Cause & Effect” or system configuration. Ability to run BS5839 part 6 system for HMO
    Details
  • Extended capacity:; The Pearl supports up to 636 loop devices (159 detectors plus 159 modules per loop) Longer loops, but fewer of them, will give the opportunity to save on installation time, cost and wiring Highly resilient Opal system, able to pinpoint a loop fault whilst maintaining full system operation Powerful networking capability - Up to 16 Pearl panels, controlling over 10,000 devices, can be networked via the superfast ID2net; prioritising a fire signal to communicate across a network in under three seconds; Intuitive on-site management - backlit buttons for fast, error free situation management, and large display giving complete information at a glance Simpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector status Text programming via MS Excel spread sheet User permissions set per individual password; Unique first fix bracket with adaptations for 19” rack or flush mounting. Fast system set up and commissioning via the panel, loop “Autolearn” and advanced PC tools suite Comprehensive “Cause & Effect” programming capability Panel sounder and beacon synchronisation System extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cabling Separate text change without risk to “Cause & Effect” or system configuration. Ability to run BS5839 part 6 system for HMO
    Details
  • Low Power – The power consumption of the repeater has been minimised through energy efficient design, preserving loop current and capacity. Quiescent 1.6mA, Alarm 12.7mA Installation – The repeater can be surface or flush mounted as standard, allowing gland or conduit entrance through the rear, top or bottom of the enclosure. The device only requires a loop connection to provide both power and data, no network cabling, or external power supply is required. Event Display – Events are categorised and clearly displayed for intuitive navigation of the system status, whilst large graphical indicators show a general system overview. User Assistance – A help menu displays a list of status specific tool-tips to aid the user in accomplishing tasks, such as silencing the internal buzzer or performing a lamp test. If the user requires additional help, the contact details for site engineers and the installer are available on the screen. Multi-Language Support – The 6000/LOOP/REPEATER’s graphical user interface caters for most Western European languages and Arabic script as standard. The language for event strings is inherited from the control panel. USB Configuration – The fast USB configuration tool allows the device to be programmed with site specific data, such as contact details for site engineers and the installer along with custom logos and settings.
    Details
  • Key Features:; Cost Effective Single Loop Panel High Capacity Loop – 192 Addresses Algo-Tec 6000Plus Protocol Surface and Recessed Mounting Easy to Install Reduced False Alarms Enhanced Performance On Site Flexibility Designed to EN54-2 & 4
    Details
  • High specification interactive digital addressable fire detection and alarm system, providing a cost effective solution for small, medium and large sized builds and sites Up to 32 control panels, repeats and illuminated zonal mimics can be networked enabling system design and expansion to be easily achieved to suit the site for economic wiring and operational convenience Wires as a loop, the network’s dual channel RS485 link ensures no single fault will affect the system An extensive range comprising loop powered alarm sounders, beacons, interfaces, manual call points and sensors can all be connected to the nearest control panel using a single 2-core cable for each of the high capacity loops (up to 4), accommodating up to 191 devices per Loop, 512 maximum per panel.
    Details
  • Key Features:; Distributed network of display and control nodes (DCN’s) and loop processing nodes (LPN’s) providing a cost effective solution for medium and large sized buildings and sites Wires as a loop, the network’s dual channel RS485 link ensures that no single fault will affect the system Alarm sounders, beacons, interfaces, manual call points and sensors can all be loop powered The Protec Algo-Tec 6000 interactive fire sensor utilize advanced discrimination algorithms for maximum reliability and immunity to false alarms.
    Details
  • Clear backlit alphanumeric / LED displays Compact size Loop powered, no separate supply required
    Details
  • Design certified to EN54 parts 2&4 1997, The SenTRI Four panel manages up to 4 loops up to 1km long, accommodating up to 200 devices on each loop. Can be upgraded to 72-hour standby The panel's software allows fire plans to be precisely tailored to site requirements Flexibility of design as up to 10 panels can be connected on a single network
    Details
  • Complies with EN54: Parts 2 & 4 One loop and two loop options Network options for large systems Up to 200 device capacity per 1km loop 8 line x 40 character LCD back-lit display 32 zonal fire LEDs, hidden until lit Simultaneous display of first and current fires Password protection for user controls Suitable for small to medium sized projects; Model: SENTRI2-NC Shipping Weight: 100gms SenTRI network card for up to 32 control panels
    Details
  • An EN54 approved networkable panel which can be configured with up to two detection loops, accommodating up to 200 devices per detection loop, this panel is an ideal solution for medium to large sites and campuses. 8 x 40 character LCD display Lockable outer door prevents tampering with controls Password protection of engineering functions LED indication of zones on fire
    Details
  • An EN54 approved single loop analogue addressable panel managing up to 127 devices. Ideal for small to medium sized businesses. Flush or surface mounted Configurations can be designed by using the offline function in the commissioning tool All detection and alarm devices connected to the same 2 core loop
    Details
  • Product Details; Model: SENTRI2-PSU-N Shipping Weight: 2000gms
    Details
  • PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating one MZX DIGITAL loop CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers BV, UL, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions
    Details
  • Spare Key for SenTRI 2 and SenTRI 4 Outer Door (Pack of 10) Model: VS-KEY Shipping Weight: 200gms
    Details
  • EN54 Compliant MXDigital system Integral power supply Optional integral eighty way zonal LED’s Two to eight loops or network up to 396 loops 250 addresses per loop Full range of MZX virtual multi-sensor detectors MZX FASTLOGIC fuzzy logic smoke detection algorithms Fully functional repeater Powerful MXConsys & MXConsys Express configuration software Easy to install Space for 17Ah or 38Ah batteries
    Details
  • FIM800 field interface PCB incorporating one or two MZX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers LPCB, BV, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions
    Details
  • Long term service and support Two way IR communications with Generation 6 Detectors reduces commissioning and service costs. Supports 1 MZX Digital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with “Front Panel Controls” to reduce lifetime cost of ownership Wide range of multi-sensor detectors including the 3oTec triple sensing detections. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 "Critical" Matching 16 Zone Fully Functional Mains powered Repeater Approved to EN54 the system is designed to be installed to BS5839
    Details
  • 1-4 loop, expandable by loop cards 20 zone LEDs 250 programmable zones Multi-language support (English, Spanish, Portuguese, French, Hungarian, Italian, Lithuanian & Dutch) Day/night mode delays 4 x 40-character LCD display Real Time Clock 4096 entry event logs 20-character device text 18-character zone text Zone or Device Disablement 2 x conventional sounder circuits Aux 24V supply 1 x fire relay 1 x fault relay Outputs programmable by zones Can be configured via PC or via Panel
    Details
  • Key Features:; One or Two loop addressable fire alarm panel (64, 126 or 252 device capacity) Certified to EN54 parts 2 & 4 User definable zones Option for zonal or common alarm operation Options for I/O operation Alarm verification (help prevent false alarms) User selectable languages Set of changeover relay contacts for fault condition Set of changeover relay contacts for fire condition 2,048 event log (fire & fault) Zone or device disablement One-man test mode Plug & play, no need for any special tools or laptop for commissioning Fully integrated keypad All associated devices are loop powered
    Details
  • Remote control and indication Up to 32 remote units connected to each main panel 4 row 160 character LCD Replicates main panel fascia Restore disabled sounders facility
    Details
  • Build-in thermal printer with paper replacement from the front 2 loops expandable to 4 with up to 512 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizard and default regional setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
    Details
  • Build-in thermal printer with paper replacement from the front 2 loops expandable to 4 with up to 512 zones and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizards and default regional setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
    Details
  • 1 loop with up to 64 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Key Features:; 1 loops with up to 64 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 1 loop with up to 64 zones Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure with username and password History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Key Features:; 1 loops with up to 64 zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details