  • Product Description The Edwards EST SIGA-UIO6R Universal Input/Output Module Board provides mounting and wiring terminations for up to six I/O modules. Signature Series Universal Input/Output Module Boards are compatible only with SIGA-“M” Series I/O Modules, which require a Signature Data Controller.
    Details
  • Product Description The Edwards EST SIGA-UM is an intelligent analog Addressable device whose function is determined by the “personality code” selected by the installer. The module’s on-board microprocessor measures and analyzes the signal and decides whether or not to input an alarm. The EST SIGA-UM Universal Class A/B Module is designed for use with GE's Signature Loop Controller only. The SIGA-UM mounts to a standard North American 2-gang electrical box, making it ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-UM may be used to connect any one of the following: — two Class B or one Class A Initiating Device Circuits — one Class A or B Notification Appliance Circuit — one Class A or B Circuit for 2-wire Smoke Detectors — one Form “C” (NO/NC) Dry Output Contact Relay
    Details
  • Product Description The Edwards EST SIGA-UMI is a Universal Class A/B Module Use with SIGA-MP1, SIGA-MP2 or SIGA-MP2L mounting plate.
    Details
  • Product Description Edwards EST SIGA-WTM Waterflow Tamper Module is an intelligent analog addressable device used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). For use with Edwards EST Signature Loop Controller only. The SIGA-WTM modules mount to North American 2-1/2 inch (64 mm) deep one-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates.
    Details
  • Product Description Edwards EST SIGA2-HCOS is a Intelligent Second Generation Combination Fixed Temperature / Rate-of-Rise Heat Detector - 135F, 15F per minute and CO sensor. Designed for use with the Signature Series Controller. COMPATIBLE BASES and ACCESSORIES: — SIGA-SB Detector Mounting Base - Standard — SIGA-SB4 4-inch Detector Mounting Base w/ SIGA-TS4 Trim Skirt — SIGA-RB Detector Mounting Base w/Relay — SIGA-RB4 4-inch Detector Mounting Base w/Relay w/ SIGA-TS4 Trim Skirt — SIGA-IB Detector Mounting Base w/Fault Isolator — SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator and SIGA-TS4 Trim Skirt — SIGA-LED Remote Alarm LED. (Connects to the SIGA-SB or SIGA-SB4 Standard Base only.) — SIGA-AB4G Audible (Sounder) Base for Fire Detectors — SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors — SIGA-TCDR Temporal Pattern Generator — SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. — SIGA-TS4 Trim Skirt (supplied with 4-inch bases) — SIGA-DMP Detector Mounting Plate — SIGA-RTA Detector Removal Tool — SIGA-VA Detector Cleaning Tool
    Details
  • Product Description NOTE: This part is discontinued by the manufacturer. Replace with — SIGA-HFD — SIGA HFS Edwards EST SIGA2-HFS Fixed Temperature Heat Detectors are only for use with Signature Loop Controller. Fixed temperature (135F) or rate-of-rise heat detection with optional carbon monoxide sensor. COMPATIBLE BASES and ACCESSORIES: — SIGA-SB Detector Mounting Base - Standard — SIGA-SB4 4-inch Detector Mounting Base w/ SIGA-TS4 Trim Skirt — SIGA-RB Detector Mounting Base w/Relay — SIGA-RB4 4-inch Detector Mounting Base w/Relay w/ SIGA-TS4 Trim Skirt — SIGA-IB Detector Mounting Base w/Fault Isolator — SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator and SIGA-TS4 Trim Skirt — SIGA-LED Remote Alarm LED. (Connects to the SIGA-SB or SIGA-SB4 Standard Base only.) — SIGA-AB4G Audible (Sounder) Base for Fire Detectors — SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors — SIGA-TCDR Temporal Pattern Generator — SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. — SIGA-TS4 Trim Skirt (supplied with 4-inch bases) — SIGA-DMP Detector Mounting Plate — SIGA-RTA Detector Removal Tool — SIGA-VA Detector Cleaning Tool — 2-CORPL Replacement CO Sensor
    Details
  • Product Description NOTE: This part is discontinued by the manufacturer. Replace with — SIGA-HRD — SIGA-HRS Edwards EST SIGA2-HRS Intelligent Fixed and Rate-of-Rise Heat Detector provides a 15 °F (9 °C) per minute rate-of-rise heat sensor for the detection of heat due to fire. The SIGA2-HRS is part of GE's Signature Series of Intelligent Heat Detectors with Optional CO Sensors. For use with Signature Loop Controller. COMPATIBLE BASES and ACCESSORIES: — SIGA-SB Detector Mounting Base - Standard — SIGA-SB4 4-inch Detector Mounting Base w/ SIGA-TS4 Trim Skirt — SIGA-RB Detector Mounting Base w/Relay — SIGA-RB4 4-inch Detector Mounting Base w/Relay w/ SIGA-TS4 Trim Skirt — SIGA-IB Detector Mounting Base w/Fault Isolator — SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator and SIGA-TS4 Trim Skirt — SIGA-LED Remote Alarm LED. (Connects to the SIGA-SB or SIGA-SB4 Standard Base only.) — SIGA-AB4G Audible (Sounder) Base for Fire Detectors — SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors — SIGA-TCDR Temporal Pattern Generator — SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. — SIGA-TS4 Trim Skirt (supplied with 4-inch bases) — SIGA-DMP Detector Mounting Plate — SIGA-RTA Detector Removal Tool — SIGA-VA Detector Cleaning Tool — 2-CORPL Replacement CO Sensor
    Details
  • Product Description NOTE: This part is discontinued by the manufacturer. Replace with: SIGA-OSHCD. The Edwards EST SIGA2-PHCOS is an Intelligent Multisensor Photoelectric/Heat Detector with Carbon Monoxide Sensor. Designed for use with the Signature Loop Controller. COMPATIBLE BASES and ACCESSORIES: — SIGA-SB Detector Mounting Base - Standard — SIGA-SB4 4-inch Detector Mounting Base w/ SIGA-TS4 Trim Skirt — SIGA-RB Detector Mounting Base w/Relay — SIGA-RB4 4-inch Detector Mounting Base w/Relay w/ SIGA-TS4 Trim Skirt — SIGA-IB Detector Mounting Base w/Fault Isolator — SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator and SIGA-TS4 Trim Skirt — SIGA-LED Remote Alarm LED. (Connects to the SIGA-SB or SIGA-SB4 Standard Base only.) — SIGA-AB4G Audible (Sounder) Base for Fire Detectors — SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors — SIGA-TCDR Temporal Pattern Generator — SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. — SIGA-TS4 Trim Skirt (supplied with 4-inch bases) — SIGA-DMP Detector Mounting Plate — SIGA-RTA Detector Removal Tool — SIGA-VA Detector Cleaning Tool
    Details
  • Product Description NOTE: This part is discontinued by the manufacturer. Replace with SIGA-PHD, or SIGA-PHS for applications that do not require split photo/heat operation. Edwards EST SIGA2-PHS Intelligent Second Generation 3D Multisensor - Photoelectric, Heat COMPATIBLE BASES and ACCESSORIES: — SIGA-SB Detector Mounting Base - Standard — SIGA-SB4 4-inch Detector Mounting Base w/ SIGA-TS4 Trim Skirt — SIGA-RB Detector Mounting Base w/Relay — SIGA-RB4 4-inch Detector Mounting Base w/Relay w/ SIGA-TS4 Trim Skirt — SIGA-IB Detector Mounting Base w/Fault Isolator — SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator and SIGA-TS4 Trim Skirt — SIGA-LED Remote Alarm LED. (Connects to the SIGA-SB or SIGA-SB4 Standard Base only.) — SIGA-AB4G Audible (Sounder) Base for Fire Detectors — SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors — SIGA-TCDR Temporal Pattern Generator — SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. — SIGA-TS4 Trim Skirt (supplied with 4-inch bases) — SIGA-DMP Detector Mounting Plate — SIGA-RTA Detector Removal Tool — SIGA-VA Detector Cleaning Tool
    Details
  • Product Description NOTE: This part is discontinued by the manufacturer. No direct replacement is recommended. Edwards EST SLIC Signature Loop Intelligent Controller Card Module is intended for use with QuickStart Series FACPs.
    Details
  • Product Description The Edwards SWU-8 is a Remote Annunciator Lamp and Switch Module.
    Details
  • Product Description The Edwards EST WG4GSKT is a Full Body Mounting Gasket for smooth surfaces. Designed for use with Genesis WG4 Series Notification Appliances.
    Details
  • Product Description The Edwards EST WG4RF-HVMC is a red Outdoor/Indoor Horn Strobe for wall or ceiling mounting. COMPATIBLE ACCESSORIES — WG4RTS Surface trim skirt, red — WG4GSKT Full Body Mounting Gasket for smooth surfaces
    Details
  • Product Description The Edwards EST WG4RF-S is a red Evacuation Speaker marked "FIRE." 25/70V RMS Operating Voltage
    Details
  • Product Description The Edwards Adaptabel 340-6N5 6-inch AC Vibrating Bell produces a long continuous sound. Power requirements: 120VAC / .070Amps PLC Compatible Mounts directly on surface or electrical box with Universal Adaptaplate.
    Details
  • Product Description Edwards 047327-0242-X1 Replacement Board
    Details
  • Product Description Edwards 130336P
    Details
  • Product Description Edwards EST 140279 ADMM Annunciator Driver Master Module
    Details
  • Product Description Edwards Signaling 1500-1 Door Holder Extension Rods are for use where it is desired to hold doors open and where a standoff distance between the magnet assembly and the armature base is required. The extension kit can be used with Edwards 1504, 1505, 1508 and 1509 series door holders. 1.5" Extension
    Details
  • Product Description Edwards EST 1534-1 Key-operated Fire Alarm Station is fitted with a key-operated switch of which the key is not easily duplicated. Stations use spanner head screws for mounting to the backbox. The 1534-1 has one Single Pole Normally Open contact rated for 1 amp at 24 Vdc. Features a 6-inch (150mm) wire leads for easy field wiring. They key can be removed in both the “ON” and “OFF” positions. Flush mounts to any standard North American 1-gang electrical box 2-1/2 inch (63mm) deep minimum, or surface mounts to Edwards 46292- 0200 Surface Mount Backbox.
    Details
  • Product Description The Edwards EST 2-CPU is a command point for remote annunciators in the EST2 network, and acts as the primary interface between the network and remote annunciators.
    Details
  • Product Description Edwards EST 2-LCD Fire Alarm Display
    Details
  • Product Description Edwards EST 2-LCD Fire Alarm Display Module
    Details
  • Product Description The Edwards EST 2-LCX Expander Loop Module is intended for use with the EST2 Fire Alarm Control Panel. Features 2 NCA (Notification Appliance Circuits) and 2 SDC (Signature Data Circuits). Requires programming.