  • Communication and control interface to MZX-Technology Fire Controllers Approved to EN54-13 ensuring system compatibility Integrated short-circuit isolator removes the need of installing a separate short-circuit isolator Reduced installation costs Meets the requirements of EN54 Pt. 11 and EN54 Pt. 17. IP67 rating for outdoor installations
    Details
  • Communication and control interface to MZX Technology Fire Controllers Approved to EN54-13 ensuring system compatibility Integrated short-circuit isolator removes the need of installing a separate short-circuit isolator Reduced installation costs Meets the requirements of EN54 Pt. 11 and EN54 Pt. 17. Marine Approved
    Details
  • Communication and control interface to MZX Technology Fire Controllers Approved to EN54-13 ensuring system compatibility Integrated short-circuit isolator removes the need of installing a separate short-circuit isolator Reduced installation costs Meets the requirements of EN54 Pt. 11 and EN54 Pt. 17.
    Details
  • Key Features:; Integral LED for easy identification of operation Call points are identified separately at the controller even for conventional panels For ease of installation various configurations are available Accidental operation can be prevented by optional covers
    Details
  • Key Features:; Integral LED for easy identification of operation Call points are identified separately at the controller even for conventional panels For ease of installation various configurations are available Accidental operation can be prevented by optional covers
    Details
  • Anti-Tamper Feature - The new Call Point, once installed, cannot be tampered with. If the lid of a device is removed without isolation from the panel, the alarm will sound. The lid fixing is also now designed to be more secure. The special MCP tool is needed to release the lid as required by EN54-11. Above Standard - The new Call Points are EN54 compliant in any format. The MCP design is ready to meet specifications for both break glass and resettable Call Point options. Compatible - The MCP has an alert Call Point with a 470 ohm Alarm Level Resistor and is fully compatible with all the current mounting accessories. The surface mount box, pattress and terminal trays all work with the new design. The MCP200/230 fits easily to most established electrical outlet boxes in the world. Integrated Design - A modular integrated functional component is at the heart of each product. This allows easy replacement of the facia should the installed unit ever be damaged. A change of application or colour can be catered for as can a system upgrade if required. Flexibility - The MCP200/230 break glass can quickly become an EN54-11 resettable MCP200/230. A resettable Call Point can easily be converted back to a break glass. With the new design it only takes a change of operating element. The solution is simple and low cost and is much easier than changing the product or adding springs and additional parts. Single Maintenance Tool - The combined test, reset and lid release facility means only one tool is needed for maintenance. The same tool will also test the existing range of Call Points so you don't need to carry a variety of different keys.
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Intrinsically Safe Weatherproof to IP67 Compatible with System 620; Conventional Call Point - Data Sheet
    Details
  • Key Features:; Integral LED indicator for easy identification of operation Surface or flush mounting Extensive range of conventional and digital addressable call points Test key facility speeds maintenance visits Optional transparent hinged cover Hazardous areas models available IP67 Waterproof models for external applications
    Details
  • Key Features:; Dual pole 24Vdc relay contact (60VA) Status indicator LED Low power consumption (<20uA except start up) Latching operation Can be used instead of a standard base Requires diode fitting if used in place of a diode base.
    Details
  • Approved by all major classification societies for use on vessels EN54 Approved from LPCB Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Wiring polarity independent
    Details
  • Key Features:; Approved by all major classification societies for use on vessels EN54 Approved from LPCB Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Wiring polarity independent
    Details
  • Key Features:; Weight 228g Humidity: up to 95% (non- condensing) Operating temperature: -10 Celsius to +55 Use only with ZX/MX Fire Alarm Controllers
    Details
  • Key Features:; Weight 228g Humidity: up to 95% (non- condensing) Operating temperature: -10 Celsius to +55 Use only with ZX/MX Fire Alarm Controllers
    Details
  • Loop Powered - Reduced installation costs High Output/Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder/LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suits individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time; Models Available
    Details
  • Loop Powered - Reduced installation costs High Output/Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder/LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suits individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time; Models Available
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • DPK6 for use with Generation6 multi-sensor detectors 850PH and 830PH with built-in 4B-C 4” Continuity Base Designed to comply with EN 54-27 One-pipe air sampling system Patented venturi pipe and duct housing Test hole on cover Simple installation Simple service and maintenance
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 For use in hazardous areas Robust GRP construction Powerful Output, up to 118dBA; Terminals: 6 x 2.5mm2 Mounting: Stainless steel bracket with ratchet facility Cable Entries: 2 x 20mm EExd. Tone Selection: 27 user selectable tones. Certification: CENELEC EN50014,18,19 BASEEFA Cert. No. BAS00ATEX2097X, EExd IIC. Zones 1 and 2. Material: Body & horn in anti-static, UV stable, glass reinforced polyester. Swivel bracket & captive cover screws in stainless steel. Nominal Output (dBA) Input Current (mA)* 93 50 105 100 108 150 111 200 112 250 114 300 115 350 118 380 Product Code 576.501.049 Flameproof Horn Sounder (DB3D048N2BNR) Output measured with 24VDC input voltage. Tone set to 970Hz continuous. Weight: 6.0kg approx Ingress Protection: IP66 / IP67 Voltage: 12VDC to 48VDC Certified Temperature: -20o C to +70o C
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Intrinsically safe Weatherproof to IP66/IP67 Robust GRP Housing; Model: BG3I 514.001.059 Intrinsically Safe Callpoint (BG3I4NBN) Protection: Explosion Protected EExia (Intrinsically Safe) Certification: CENELEC EN50014, 020 BASEEFA EExia IIC T4 Cert No. BAS00ATEX1067X Suitable for use in Zones 0,1 & 2 Voltage: Up to 28V (IS) Certified Temp: -55°C to +55°C Ingress Protection: IP66 & IP67 European Standard for Callpoints: EN54-11 Terminals: 6 X 4.0mm2 Cable Entries: 2 X M20 Bottom Weight: 0.5Kg Material: UV resistant glass reinforced polyester Finish: Natural Red GRP
    Details
  • Glass Reinforced Polyester Enclosure - light, strong and not subject to corrosion. Resettable Element. Explosion protected EExe (ATEX Approved). In line and end of line resistors. Red Epoxy Finish. 7 x terminals. Lift flap for extra protection against inadvertent operation. 1 x changeover switch. Captive cover screws. Key operated test facility - simple but secure. 1 x M20 bottom cable entry.
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Polyester Enclosure - light, strong and not subject to corrosion. Break Glass. Explosion protected EExe (ATEX Approved). In line and end of line resistors. Red. 9 x terminals. Lift flap for extra protection against inadvertent operation. 1 x changeover switch. Captive cover screws. No hammer required - the glass is covered by a membrane thus protecting the operator from glass fragments. Key operated test facility - simple but secure. 2 x M20 bottom cable entries.
    Details
  • Power beam detectors directly from the MX Digital loop Reduced wiring and installation costs Monitors beam detector for fire and fault Inter-connection monitored for open and short circuit faults LPCB and VdS appoved (pending) Can be installed to BS5839 Part 1 2002 On board LED indicated polling and active Use with reflective beams FIRERAY 50R or 100R for greater savings on installation Compatible with FIRERAY 2000 beam detector Optional BTM800 beam terminaltion module to further simplify installation
    Details
  • Advanced multi-sensor designs Built-in line isolator (851PH Only) Quick and easy to install Extended drift compensation Two way infra-red communication to the 850EMT Engineering Management Tool Fire, isolate and fault LED indications Any Pantone colour available with CPD approval Comprehensive range of bases and base accessories
    Details
  • Advanced multi-sensor designs Built-in line isolator (851PH Only) Quick and easy to install Extended drift compensation Two way infra-red communication to the 850EMT Engineering Management Tool Fire, isolate and fault LED indications Any Pantone colour available with CPD approval Comprehensive range of bases and base accessories