Key Features:; Unique Installation Concept Anti-Tamper Facility Enhanced Aesthetics Fully Approved to the Latest Standards Re-settable Break Glass Element Backward Compatibility -
Low Power – The power consumption of the repeater has been minimised through energy efficient design, preserving loop current and capacity. Quiescent 1.6mA, Alarm 12.7mA Installation – The repeater can be surface or flush mounted as standard, allowing gland or conduit entrance through the rear, top or bottom of the enclosure. The device only requires a loop connection to provide both power and data, no network cabling, or external power supply is required. Event Display – Events are categorised and clearly displayed for intuitive navigation of the system status, whilst large graphical indicators show a general system overview. User Assistance – A help menu displays a list of status specific tool-tips to aid the user in accomplishing tasks, such as silencing the internal buzzer or performing a lamp test. If the user requires additional help, the contact details for site engineers and the installer are available on the screen. Multi-Language Support – The 6000/LOOP/REPEATER’s graphical user interface caters for most Western European languages and Arabic script as standard. The language for event strings is inherited from the control panel. USB Configuration – The fast USB configuration tool allows the device to be programmed with site specific data, such as contact details for site engineers and the installer along with custom logos and settings. -
Protec Algo-Tec 6000 Protocol Loop powered High intensity LEDs Extremely long service life Integral short circuit isolator Ultra low current consumption Weather-proof to IP65 -
Infra-Red Transmitter and Receiver Technician Friendly Simple Menu System Protec Algo-Tec™ 6000 Protocol Low Power Usage FAST™ Addressing Cost Effective -
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe -
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe -
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe -
-
-
Heavy Duty Sampling Pipe Combined Filter & Condensation Trap 25mm Sampling Pipe Inlet/Outlet Airflow Direction Indicator Reduces Service Intervals Reduces Unwanted Alarms Replaceable Filter Cartridge Available -
Heavy Duty Sampling Pipe Combined Filter & Condensation Trap 25mm Sampling Pipe Inlet/Outlet Airflow Direction Indicator Reduces Service Intervals Reduces Unwanted Alarms Replaceable Filter Cartridge Available -
-
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013" -
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013" -
Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013 -
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement -
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement User Walk Test -
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode (only one zone at once in user mode) Disablement of detector circuits Disablement of alarm circuits Disablement of any programmed delays Disablement of the optional fire link interface -
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode Disablement of detector circuits Disablement of alarm circuits; Fire Detection Zones Fully Compliant with EN54 Parts 2 & 4 Manual Device Activation Indication Coincidence Detection Non-latching Zones Zone Disablements Alarm Disablements User Walk Test -
-
Discrete Anti-Tamper Security Latch Latching ‘Fire’ LED Range of Base Options Maximum Sensitivity to Heat Detection High Resistance to False Alarm Approved to EN54 & AS7240 Part 5 -
Discrete Anti-Tamper Security Latch Latching ‘Fire’ LED Range of Base Options Maximum Sensitivity to Heat Detection High Resistance to False Alarm Approved to EN54 & AS7240 Part 5 -
Enhanced Sensitivity to a Wide Range of Smoke Types High Resistance to False Alarm Ultra-Low Quiescent Current Latching ‘Fire’ LED Range of Base Options Approved to EN54 Part 5 & 7 -
Ideal for Detecting Smouldering Fire Discrete Anti-Tamper Security Latch Latching ‘Fire’ LED Range of Base Options Maximum Sensitivity to Smoke Detection High Resistance to False Alarm Approved to EN54 & AS7240 Part 7 -
Quick and simple to Install Aesthetic, low profile design Compatible with Protec 3000PLUS series detectors Robust terminal wiring Continuity diode included on 3000PLUS/BASE to comply with BS5839 Approved to EN54 when used with Protec detectors -
LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets 7.5 metres (m) Room Coverage Volume 2.4 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 23 -
LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets 7.5m Room Coverage Volume 2.4 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 23 -
Key Features:; LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets Adjustable from 3 to 7.5m Room Coverage Volume Up to 3 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 23 -
LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets 3 metres (m) Mounting Height 7.5m Room Coverage Volume Adjustable Flash Rate Approved to EN54 Part 23 -
Key Features:; Ideal where Smoke Detection is unsuitable Discrete Anti-Tamper Security Screw Latching ‘Fire’ LED Interchangeable with other 3000 Heads Range of Base Options High Resistance to False Alarm Fast Response Thermistor Reliable Heat Detection LPCB Approved to EN54 Part 5: 2000 -
Ideal where Smoke Detection is unsuitable Discrete Anti-Tamper Security Screw Latching ‘Fire’ LED Interchangeable with other 3000 Heads Range of Base Options High Resistance to False Alarm Fast Response Thermistor Reliable Heat Detection LPCB Approved to EN54 Part 5: 2000 -
Ideal where Smoke Detection is unsuitable Discrete Anti-Tamper Security Screw Latching ‘Fire’ LED Interchangeable with other 3000 Heads Range of Base Options High Resistance to False Alarm Fast Response Thermistor Reliable Heat Detection LPCB Approved to EN54 Part 5: 2000 -
High Output Electronic Sounder Low Current Consumption Weatherproof to IP65 Choice of Colours Selectable Tone Selectable Volume Optional Base for Surface Wiring; Warble 990Hz 250ms 665Hz 250ms Continuous Tone at 990Hz Pulse Tone 990Hz 500ms Silence 500ms UK Sweep Dutch Slow Whoop Reverse Sweep 1.5 Seconds Repetition Rate French Fire Tone 554Hz for 100ms, 440Hz for 400ms Pulse Tone 665Hz for 150ms Silence for 150ms Continuous Tone at 665Hz -
High Output Electronic Sounder High Intensity LED Beacon Low Current Consumption Weather-proof to IP65 Choice of Colours Selectable Tone & Volume Base for Surface Wiring -
Key Features:; Interchangeable with 3000 range sensors Low current Adjustable volume control Combining sounder and beacon 4 selectable tones -
Key Features:; Interchangeable with 3000 Range sensors Low Current Adjustable Volume Control Combined Sounder and Beacon 4 Selectable Tones -
Key Features:; Interchangeable with 3000 Range sensors Low Current Adjustable Volume Control Combined Sounder and Beacon 4 Selectable Tones -
Ideal General Purpose Fire Detector Detects Wide Range of Fire Types Discrete Anti-Tamper Screw Latching ‘Fire’ LED Interchangeable with other 3000 Heads Range of Base Options Maximum Sensitivity to Smoke Detection High False Alarm Resistance LPCB Approved to EN54 Part 7 : 2000, EN54 Part 5 : 2000 Grade A2, CEA4021:1999-06 -
Ideal for Detecting Smouldering Fire Discrete Anti-Tamper Security Screw Latching ‘Fire’ LED Interchangeable with other 3000 Heads Range of Base Options Maximum Sensitivity to Smoke Detection High Resistance to False Alarm LPCB Approved to EN54 Part 7: 2000 -
Unique Installation Concept Anti-Tamper Facility Enhanced Aesthetics Fully Approved to the Latest Standards Re-settable Break Glass Element Backward Compatibility -
Unique Installation Concept Anti-Tamper Facility Enhanced Aesthetics Fully Approved to the Latest Standards Re-settable Break Glass Element Backward Compatibility -
Infra-Red Transmitter and Receiver Technician Friendly Simple Menu System Low Power Usage Cost Effective -
Key Features:; Interchangeable with 3000 Range sensors Low Current Adjustable Volume Control Combined Sounder and Beacon 4 Selectable Tone -
Simple to install and commission Minimises discomfort to animals, while clearly alerting human beings to an alarm condition Compliant to Home Office recommendations Circuitry designed to eliminate frequencies above 470Hz in line with results recommended by research High output level with four attenuation levels available Voice versions available upon request -
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module -
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module