Enclosure mounted with battery space 110 V or 230 V input Regulated, true 24 V output Intelligent battery charging and temperature compensation House up to 7 Ah batteries Status indicators for monitored faults Dual output for powering fire alarm control panels remotely Fully enclosed and robust construction
-
Enclosure mounted with battery space 110 V or 230 V input Regulated, true 24 V output Intelligent battery charging and temperature compensation House up to 26 Ah batteries Status indicators for monitored faults Dual output for powering fire alarm control panels remotely Fully enclosed and robust construction
-
-
C-Tec BF360-12 Boxed EN54 12v 2a Power Supply Unit (VDS Certified); Max. physical battery size (with STU plate): 1 x 12V 3 Ah Max. physical battery size (no STU plate): 1 x 12V 7 Ah Standard battery charging capacity: 2 Ah to 12 Ah Output option A: 1.8A DC current, 0.2A charge current Output option B: 1.3A DC current, 0.7A charge current Enclosure size (WxHxD): 380 x 235 x 96mm Physical attributes: Plastic lid and base
-
C-Tec BF360-24 Boxed EN54 24v 1.5a Power Supply Unit (VDS Certified); Low current consumption. Deep discharge battery protection and EN54 compliant flagging of battery impedance faults. Single-pole volt-free changeover relay that switches for any fault condition. Three LED indicators - supply present, general fault and auxiliary fault (for optional connection to third-party equipment). Link selectable battery charging capacity. Optional high-temperature output activates when internal box temperature reaches 55°C, for connection to ventilation fans.
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
C-Tec 24v 1.5A EN54-4/A2 Boxed Power Supply Unit (VDS Certified); BF362-1; Low current consumption Deep discharge battery protection and EN54 compliant reporting of battery impedance faults Single-pole volt-free changeover relay that switches for any fault condition Three LED indicators - supply present, general fault and auxiliary fault (for optional connection to third-party equipment) Link selectable battery charging capacity Environmentally-friendly charging circuit - dissipates just 0.35W compared to the industry norm of around 2.55W. Optional high-temperature output activates when internal box temperature reaches 55oC, for connection to ventilation fans, etc. Optional handheld status reader (shows internal temperature, charging voltage and current of connected PSU). Serial data link also provided for third-party OEM equipment All boxed versions third-party certified to EN54-4 (1997/A2:2006) by the VdS or LPCB
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
C-Tec 24v 3A EN54-4/A2 Boxed Power Supply Unit (LPCB Certified) BF362-3; Low current consumption Deep discharge battery protection and EN54 compliant reporting of battery impedance faults Single-pole volt-free changeover relay that switches for any fault condition Three LED indicators - supply present, general fault and auxiliary fault (for optional connection to third-party equipment) Link selectable battery charging capacity Environmentally-friendly charging circuit - dissipates just 0.35W compared to the industry norm of around 2.55W. Optional high-temperature output activates when internal box temperature reaches 55oC, for connection to ventilation fans, etc. Optional handheld status reader (shows internal temperature, charging voltage and current of connected PSU). Serial data link also provided for third-party OEM equipment All boxed versions third-party certified to EN54-4 (1997/A2:2006) by the VdS or LPCB
-
Key Features:; direct fit to a single gang deep back box circular flush mounted version available without text text is available in other languages custom legend available on request IP66 weather-proof version available