Product Description The Edwards EST GSA-MM1 is a Monitor Module for use only with Vigilant’s Signature Loop Controller. Assigned to one circuit. Configures circuit 1 for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module.
-
Product Description Edwards EST GSA-MCC1S Single Input Signal Module
-
Product Description Edwards EST GSA-M27 Vigilant is a Double Action (Single Stage) Fire Alarm Manual Pull Station. Compatible for use with Vigilant's Signature Loop Controller.
-
Product Description Edwards EST GSA-M270 Vigilant Fire Alarm Pull Station is designed for use with GE's Signature Loop Controller. Single action w/ optional breakable glass rod. Electronic addressing: Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded from a PC, or the SIGA-PRO Signature Program/Service Tool.
-
Product Description The Edwards EST GSA-HFS Plug-in Intelligent Fixed Temp (135F) Heat Detector is designed for use with the Signature Loop Controller. COMPATIBLE BASES and ACCESSORIES: — GSA-SB Detector Mounting Base — GSA-SB4 4-inch Detector Mounting Base c/w GSA-TS Trim Skirt — GSA-RB Detector Mounting Base w/Relay — GSA-RB4 4-inch Detector Mounting Base /w Relay c/w GSA-TS Trim Skirt — GSA-IB Detector Mounting Base w/Fault Isolator — GSA-IB4 4-inch Detector Mounting Base w/ Fault Isolator c/w GSA-TS Trim Skirt — GSA-LED Remote Alarm LED — GSA-AB4G Audible (Sounder) Base — GSA-TS4 Trim Skirt (supplied with 4-inch bases)
-
Product Description Edwards EST GSA-CT2 Vigilant Dual Input Module mounts to standard North American 1-gang electrical boxes. Separate I/O and data loop connections are made to each module. For use with the Signature Loop Controller.
-
Product Description Edwards EST GSA-CT1 Vigilant Single Input Module mounts to standard North American 1-gang electrical boxe. Separate I/O and data loop connections are made to each module. For use with the Signature Loop Controller.
-
Product Description Edwards EST GSA-CR Vigilant Control Relay Module provides one Form “C” dry relay contact can be used to control external appliances such as door closers, fans, dampers etc. Part of the Signature Series (SIGA) system components.
-
Product Description The Edwards EST GSA-AB4 is a plug-in Audible Detector Base.
-
Product Description Edwards EST GCWN-VMC Speaker Strobe (White) is a GC Ceiling, Standard Range Strobe, No Markings, Clear Lens Strobe operating voltage 16 to 33 VDC (24 VDC nominal) or 16 to 33 VFWR (24 VFWR nominal) Speaker Operating Voltage 25 Vrms or 70 Vrms Speaker response 300 to 8,000 Hz Synchronization Sources: SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM, BPS6A, BPS10A, APS6A, APS10A, iO Series, Fireshield Plus 3, 5 and 10 zone.
-
Product Description Edwards EST GCWN-VMA Field Configurable Ceiling Strobe (white) is part of the Genesis Series. Operating Voltage: Regulated 16 to 33 VDC Mounts Flush to North-American 4” square box, at least 1½” (38 mm) deep. Surface mount using model G4EWB (white) surface mount box. Compatible Synchronization Sources: SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM, BPS6A, BPS10A, APS6A, APS10A, iO64, iO500, Fireshield Plus 3, 5 and 10 zone.
-