Dual IR detector High specification units for critical applications IP66 Housing Flame proof housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Dual Infra Red Flame Detector - Data Sheet -
Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; High Performance Optical Smoke Detector - Data Sheet -
Features:; Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Discrete ultra low profile design Fits a standard detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors; Infa-Red Flame Detector - Data Sheet -
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; CO & Rate Of Rise Heat Detector - Data Sheet -
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; Rate Of Rise Heat Detector - Data Sheet -
Key Features:; Intrinsically Safe Optical Detector Nittan Y Type Chamber Omniview 360° LED Operational Range (12v-32v) Limited to 28v by External Barrier Use UB-4-IS Base or EV-SPB-IS Base; IS Detector - Instructions IS Detector - Data Sheet -
Ziton ZC6-MCP-IS Intrinsically Safe Surface Mount Call Point 172120; SIRA certificated Modern stylish design Resettable or frangible operating elements Plug in wiring connection Single maintenance tool; IS Call Point - Data Sheet BS5839-2017 Call Point Covers Information Sheet -
Key Features:; Dual Band IR Flame Detector Omniview 360° LED Internal Alarm Current Limiting Resistor Wide Operational Voltage Range (12v-32v); IR Flame Detector - Data Sheet -
BS5839 - Call Point Covers -
Sealed to IP67 Unique ‘Plug & Play’ installation concept Total ‘Flex-Ability’ in the choice of operating element Anti-Tamper facility Enhanced aesthetics and compact design Fully approved to the latest standards CPD Approval; I.S. Call Point - Data Sheet -
Morley Call Point - Data Sheet BS5839-2017 Call Point Covers Information Sheet -
Key Features:; IS Call Point - Instructions IS Call Point - Data Sheet -
Key Features:; Sealed to IP67 Unique "Plug & Play" installation concept Total "Flex-Ability" in the choice of operating element Anti-Tamper facility Enhanced aesthetics and compact design Fully approved to the latest standards CPD Approval; Hochiki - CCP-W-IS - Datasheet -
Key Features:; IS Call Point - Instructions IS Call Point - Data Sheet -
Key Features:; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The push button is user resettable via the use of the special key supplied with the unit. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet -
Key Features:; The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; IS Call Point - Data Sheet IS Call Point - Instructions -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The product is user resettable by rotating the push button. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The push button is user resettable via the use of the special key supplied with the unit. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet -
Key Features:; The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The product is user resettable by rotating the push button. The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.; EExd Call Point - Installation Sheet EExD Call Point - Data Sheet -
Key Features:; IS Call Point - Instructions IS Call Point - Data Sheet -
Key Features:; The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphate and powder coated.; EExD Call Point - Data Sheet EExd Call Point - Installation Sheet