/All Products
  • Protective cover helps prevent malicious or accidental false fire alarms. Surface mount (32mm spacer) 96 dB sounder (at 1 metre) Prevents false alarms, without hindering legitimate operation of a manual call point in the event of an emergency. Glows in the dark. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Polycarbonate tested -40°C (-40°F) to 49°C (120°F). 104 mm H x 96 mm W x 58 mm D
    Details
  • Protective cover helps prevent malicious or accidental false fire alarms. Surface mount (32mm spacer) Non-sounder Prevents false alarms, without hindering legitimate operation of a manual call point in the event of an emergency. Glows in the dark. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Polycarbonate tested -40°C (-40°F) to 49°C (120°F). 104 mm H x 96 mm W x 58 mm D
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 20m sec to flash fire Solar blind Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year warranty User programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance: EN54-10 (VdS) - FM3260; Explosives & munitions Offshore Oil & Gas Onshore Oil & Gas Petrochemical plants Storage tank farms Aircraft hangars Chemical plants Power generation facilities Pharmaceutical industry Printing industry Warehouses Automotive industry Waste disposal facilities Aerospace industry Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging Areas Refinery Hydrogenation Space Industry Hydroxyl Propellant Static Fuel Cell Systems; Spectrex 40/40UFL - Data Sheet Spectrex 40/40UFL - User Guide Spectrex 40/40UFL - Accessories
    Details
  • Multi Spectrum Design - for long distance detection and high false alarm immunity High Speed Response – 50m sec Sensitivity Selection - to ensure no zone crossover detection Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Safety Integrity Level SIL2 (TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance: EN54-10 (VdS) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Spectrex 40/40UFI - Data Sheet Spectrex 40/40UFI - User Guide Spectrex 40/40UFI - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40UB - Data Sheet Spectrex 40/40UB - User Guide Spectrex 40/40UB - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40U - Data Sheet Spectrex 40/40U - User Guide Spectrex 40/40U - Accessories
    Details
  • Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested - EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Spectrex 40/40R - Data Sheet Spectrex 40/40R - User Guide Spectrex 40/40R - Accessories
    Details
  • Multi spectrum design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static fuel Cell systems; Spectrex 40/40M - Data Sheet Spectrex 40/40M - User Guide Spectrex 40/40M - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40LB - Data Sheet Spectrex 40/40LB - User Guide Spectrex 40/40LB - Accessories
    Details
  • UV/IR Dual-Sensor Solar blind Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation (in 40/40L4B only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) Model 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Approved - EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L4B - Data Sheet Spectrex 40/40L4B - User Guide Spectrex 40/40L4B - Accessories
    Details
  • UV/IR Dual-Sensor Solar blind Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation (in 40/40L4B only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) Model 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Approved - EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L4 - Data Sheet Spectrex 40/40L4 - User Guide Spectrex 40/40L4 - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L - Data Sheet Spectrex 40/40L - User Guide Spectrex 40/40L - Accessories
    Details
  • Multi spectrum design - for long distance detection and high false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities; Spectrex 40/40I - Data Sheet Spectrex 40/40I - User Guide Spectrex 40/40I - Accessories
    Details
  • Versions available:; PN 789260-3 – Pipe 4” Version PN 789260-1 – Pipe 3” Version PN 789260-2 – Pipe 2” Version; Spectrex 40/40 Series - Accessories
    Details
  • Versions available:; PN 789260-3 – Pipe 4” Version PN 789260-1 – Pipe 3” Version PN 789260-2 – Pipe 2” Version; Spectrex 40/40 Series - Accessories
    Details
  • Versions available:; PN 789260-3 – Pipe 4” Version PN 789260-1 – Pipe 3” Version PN 789260-2 – Pipe 2” Version; Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Installation Guide Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex Airsheild - Installation Guide Spectrex 40/40 Series - Accessories
    Details
  • Product Details; Model: SENTRI2-PSU-N Shipping Weight: 2000gms
    Details
  • Spare Key for SenTRI 2 and SenTRI 4 Outer Door (Pack of 10) Model: VS-KEY Shipping Weight: 200gms
    Details
  • Key Features:; Exceeds the illumination requirements of EN54-23 Patented electronic design maximises system efficiency by minimising power consumption Reduces the number of devices required most rooms can be protected with a single device Installation is quick and simple with mounting and wiring made only to the base the head clicks on to the base during commissioning Sonos Pulse VADs share the same base mounting and wiring as previous versions make the transition to Pulse versions as simple as possible Pulse Alert Technology enables the coverage pattern to be fixed at the optimum performance level Sonos Pulse VADs protect everyone including people prone to photosensitivity epilepsy Eliminates power surges during system start up Surpasses the ingress protection requirements of EN54-23 making them suitable for a wide variety of environmental conditions
    Details
  • Solo 365 - ES3 - smoke detector tester
    Finally a compact smoke cartridge for use with Solo 365.  The Solo ES3 cartridge has non-hazardous and non-pressurized – therefore making it easy storage above all easy for transportation. In conclusion, this is the future of smoke detector testing along with to Solo 365 which it will be used with. Key features include:
    • Detector manufacutrer approved
    • Solo Es3 is Non-flammable, non-pressurised & non-hazardous
    • Rapid activation of detectors
    • Compact design
    • Product code: Solo ES3-001
    Details
  • C3 with Solo 330 Solo C3 Detector Tester
    Designed for functional testing of detector testers, the Solo C3 Aerosol ensures that detectors that respond to smoke are in full working order. Non-flammable, this product is the professional’s choice for value in aerosol smoke. Key features include:
    • Detector manufacturer endorsed
    • Non-flammable CO stimulus
    • Enables controlled delivery over short bursts
    • Compatible with Solo 330/332 dispensers
    • Product Code: Solo C3-001
    Details
  • Solo A10s canned smoke detector tester
    Approved all over the world, our Solo smoke aerosols (used with the Solo 330/332 dispensers) deliver smoke particles to the detector under test replicating the conditions of smoke from a fire. Our range of smoke aerosols has recently increased to allow continued use of our Solo 330/332 dispensers in full compliance with latest regulations.
    Key features include:
    • Detector manufacturer approved
    • Designed for use with Solo 330 dispenser
    • Compliant with regulations
    • UL certified
    • Product Code: Solo A10S, Solo A5
    Details
  • Another of our best sellers, the Solo 823 allows safe, effective testing and removing of smoke and heat detectors of up to 9 meters high. Kit includes:
    • Solo 330 Aerosol Dispenser
    • Solo 461 Cordless Heat Detector Tester
    • Solo 100 Access Pole
    • 3 x Solo 101 Extension Pole
    • Solo 200 Detector Removal Tool
    • Solo 610 Storage Bag
    • Provides access to detectors up to 9m
    • Product Code: Solo 823-001
    Details
  • Designed to aid testing at height, the Solo 822 kit contains everything you need for safe removing and testing of both smoke and heat detectors. Kit includes:
    • Solo 330 Aerosol Dispenser
    • Solo 461 Cordless Heat Detector Tester
    • Solo 100 Access Pole
    • Solo 200 Detector Removal Tool
    • Solo 610 Storage Bag
    • Provides access to detectors up to 6m
    • Product Code: Solo 822-001
    Details
  • The Solo 811 is a kit designed to aid with removal, replacement and testing of smoke detectors up to 6 metres. Kit includes:
    • Solo 330 Aerosol Dispenser
    • Solo 100 Access Pole
    • Solo 200 Detector Removal Tool
    • Solo 610 Storage Bag
    • Provides access to detectors up to 6m
    • Product Code: Solo 811-001
    Details
  • The Solo 810 kit is ideal for testing smoke detectors at heights up to 2.5 metres. Kit includes:
    • Solo 330 Aerosol Dispenser
    • Solo 101 Extension Pole
    • Provides access to detectors up to 2.5m
    • Product Code: Solo 810-001
    Details