Combined transmitter and receiver unit Unique servo-operated test filter (6500RS) Range 5-100m 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom Automatic drift compensation Complies to EN54-12:2002 Extended warranty
-
Combined transmitter and receiver unit Unique servo-operated test filter (6500RS) Range 5-100m 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom Automatic drift compensation Complies to EN54-12:2002 Extended warranty
-
Combined transmitter and receiver unit Range 10-100 metres using the long range reflector kit 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-Red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom ±10° horizontal and vertical beam alignment Automatic drift compensation Loop powered Complies to EN54-12 Extended Warranty
-
5 – 100m operating range, designed for the protection of buildings such as shopping centres, heritage buildings, warehouses and other structures with large open spaces Easy set-up and calibration with visual aids for both coarse and fine adjustment Loop powered with built in isolation for system mapping Utilizes the advanced Opal digital protocol whilst remaining backward compatible with existing Notifier system The NFXI-BEAM-T Beam Detector features a unique remote test capability that fully tests both the optics and the electronics of the device. This means there’s no need to hire a platform to give high level access to the device in testing. Two automatically variable sensitivity modes compensate for short term environmental changes Automatic drift compensation compensates for long term sensitivity changes caused by environmental factors Four fixed sensitivity level
-
5 – 100m operating range, designed for the protection of buildings such as shopping centres, heritage buildings, warehouses and other structures with large open spaces Easy set-up and calibration with visual aids for both coarse and fine adjustment Loop powered with built in isolation for system mapping Utilizes the advanced Opal digital protocol whilst remaining backward compatible with existing Notifier system The NFXI-BEAM-T Beam Detector features a unique remote test capability that fully tests both the optics and the electronics of the device. This means there’s no need to hire a platform to give high level access to the device in testing. Two automatically variable sensitivity modes compensate for short term environmental changes Automatic drift compensation compensates for long term sensitivity changes caused by environmental factors Four fixed sensitivity level
-
Infra-Red Transmitter and Receiver Technician Friendly Simple Menu System Low Power Usage Cost Effective
-
Infra-Red Transmitter and Receiver Technician Friendly Simple Menu System Protec Algo-Tec™ 6000 Protocol Low Power Usage FAST™ Addressing Cost Effective
-
-
Unique servo-operated test filter Combined transmitter and receiver unit Range 5-100m (with the long-range reflector kit) 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom Automatic drift compensation Uses the Series 200 Advanced Protocol Loop powered Complies to EN54-12:2002 Extended warranty
-
Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller Supply voltage: 12-36VDC Current: Controller 14mA, per transmitter head 8mA Fire and Fault relays per detector head - rated 2A 30VDC Detector head dimensions per transmitter and receiver unit (mm): 74w x 74h x 161d Controller dimensions (mm): 203w x 124h x 73d
-
Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller
-
Single installation and maintenance point Fully addressable 100 metre detection range Unique simple alignment Selectable alarm thresholds Latching or auto reset fire output Automatic contamination compensation