High sensitivity provided by laser based forward light scatter for reliable early warning Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laster dust discrimination and elimination system 4 sampling pipes, up to 250m maximum total length RS485 communications built in as standard for networking and remote communications
-
A fully integrated and compact system, designed for larger pipe networks Designed for use in Honeywell Aspiration Smoke Detection ( ASD) systems Patented design without air resistance (as defined by EN 54-20) 6 user selectable preventive or event-triggered purging programs Internal clock or external clock timer can be connected Several systems can be coupled in Master-Slave mode Manual control via external push-button Automatic initiation if a fault message is received from the ASD system (activating through FACP only) Easy commissioning without software tools Multi-coloured LED indicates the system condition
-
High sensitivity provided by laser based forward light scatter for reliable early warning Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laster dust discrimination and elimination system 4 sampling pipes, up to 250m maximum total length RS485 communications built in as standard for networking and remote communications
-
Ultra small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provide by laser based forward light scatter for reliable early warning Signal sampling pipe up to 50m in length Unique ClassiFire perceptive artificial intelligent system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protect environment and dust separation system contamination Unwanted alarm from dust are avoided using patented Dual Technology LDD 3D Laser Dust Discrimination and elimination system
-
Small, low cost aspirating smoke detector for easy and discreet installation High sensitive provided by laser based forward light scatter for reliable early warning Two sampling pipes (100m aggregate) for flexibility Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detector’s operating parameters allowing for day to day changes in the protected environment and the system contamination Unwanted alarms from dust are avoided using patented dual technology LDD 3D laser dust discrimination and elimination system
-
Ultra small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provide by laser based forward light scatter for reliable early warning Signal sampling pipe up to 50m in length Unique ClassiFire perceptive artificial intelligent system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protect environment and dust separation system contamination Unwanted alarm from dust are avoided using patented Dual Technology LDD 3D Laser Dust Discrimination and elimination system
-
Small, low cost aspirating smoke detector for easy and discreet installation High sensitive provided by laser based forward light scatter for reliable early warning Two sampling pipes (100m aggregate) for flexibility Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detector’s operating parameters allowing for day to day changes in the protected environment and the system contamination Unwanted alarms from dust are avoided using patented dual technology LDD 3D laser dust discrimination and elimination system
-
Designed to bring the benefits of laser based aspirating smoke detection to applications where cost would previously have limited installations to ‘point detector in a fan box’ type systems High sensitivity provided by laser based light scatter for reliable early warning Laser smoke sensor chamber specially designed for aspirating detection avoids the airflow problem associated with ‘point-in-a-box’ type solutions Up to 50m of sampling pipe with 10 sampling holes Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laser dust discrimination and elimination system Easy commissioning without the need for a PC
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable