/All Products
  • 1 sampling pipe / 1 detector EN 54-20 classes A, B, and C 4 alarm levels (1 fire alarm, 3 fixed pre-alarms 30 / 50 / 70% when using RIM36 Module) Response sensitivity settable from 0.006–10%/m Insensitive to dirt particles due to particle suppression Low noise level, compliant with ISO 11690-1 Perfected smoke detection with HD sensor (high-dynamic technology) Low power consumption Onboard Configuration ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
    Details
  • 1 sampling pipe/1 detector EN 54-20 classes A, B, and C 5 alarm levels (3 pre-alarms and 2 alarms when using RIM36 Module) Response sensitivity settable from 0.002–10%/m Insensitive to dirt particles thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Perfected smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption ASD Config PC tool ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
    Details
  • Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
    Details
  • Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
    Details
  • Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
    Details
  • Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
    Details
  • PhD Satellite Programming Station
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • "Precept DC EN 16 Zone Repeater Panel with no Power Supply - 2605116 The 2605116 is a 16 Zone Precept Repeater Panel. The Precept Repeater Panel range can be 8, 16 or 32 Zone. The Precept AC range comes with a power supply whereas the Precept DC range doesn’t come with a power supply. The Precept Repeater Panel can range from 8, 16 or 32 Zone. As this Repeater Panel doesn't come with a power supply, it is powered from the Main Control Panel."
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details